Banner D10 Expert Скачать руководство пользователя страница 3

 

 

P/N 64154 rev. F

     

D10 

Expert

 Dual Discrete Outputs

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

Sensor Programming

Programming Procedures

Two push buttons, Dynamic (+) and Static (-), may be used to access and set programming parameters. For remote programming, connect a 
switch or digital input to the gray wire; length of the individual pulses is equal to the value T:

0.04 seconds ≤ T ≤  0.8 seconds

Returning to RUN mode

TEACH and SETUP modes each may be exited in one of two ways: by exercising the 60-second time-out, or by cancelling out of the process. 
In TEACH mode, the sensor will return to RUN mode without saving any of the new settings; in SETUP mode, the sensor will return to RUN 
mode but save all of the settings. To cancel out of TEACH mode, press and hold the Static (-) button for 2 seconds; to cancel out of SETUP 
mode, press and hold both the Static (-) and Dynamic (+) buttons for 2 seconds.

Output 2

The setpoint(s) for each output can be set independently of one another (see Super-High-Speed Operation). However, the functional range 
available for output 2 is dictated by the automatic power and gain settings established for output 1. Whenever output 1 is taught, output 2 also 
must be retaught. Applications hint: teach the weakest signal on output 1 first.

Active Channel Select

• Selects which channel to teach

 

• Displays channel configuration information.

Active 

Channel

 

Select

Push Button

Remote 

0.04 sec. ≤ T ≤ 0.8 sec.

Result

  Single-click 

both buttons 
simultaneously.

• Triple-pulse

 

  the remote line.* 

Pointer icon:

 moves to the 

other channel indicator.

T

T

T

T

T

T

T

T

T

T

dynamic

static

dynamic

static

*  NOTE:  Triple-pulse will change the display, but will not save. To save Channel Select, make an adjustment to that channel as a TEACH, SET, or Sensor Setup.

Содержание D10 Expert

Страница 1: ... m or 9 m 6 5 or 30 cable or integral Pico style quick disconnect Sleek ultra slim 10 mm housing mounts to a standard 35 mm DIN rail U S Patent 5 808 296 9 m 30 cables are available by adding suffix W 30 to the model number of any cabled sensor e g D10DNFP W 30 A model with a QD connector requires a mating cable see page 14 WARNING Not To Be Used for Personnel Protection Never use these products a...

Страница 2: ... or when the target is absent OFF Delay Timing Selection Programmable OFF delay pulse stretcher 0 2 5 10 15 20 30 40 60 80 or 100 milliseconds Display Selection Discrete Output Raw signal value or excess signal Power Level Speed Selection Super High Speed SHS High Speed HS High Power HP Super High Power SHP Response 50 µs 200 µs 1 ms 2 5 ms Repeatability 25 µs 50 µs 75 µs 100 µs Maximum Range Fibe...

Страница 3: ...ess and hold the Static button for 2 seconds to cancel out of SETUP mode press and hold both the Static and Dynamic buttons for 2 seconds Output 2 The setpoint s for each output can be set independently of one another see Super High Speed Operation However the functional range available for output 2 is dictated by the automatic power and gain settings established for output 1 Whenever output 1 is ...

Страница 4: ...nual Adjust page 9 Static TEACH is the traditional setup method used when two conditions can be presented by the user The sensor locates a single sensing threshold the switchpoint midway between the two taught conditions with the Output ON condition on one side and the Output OFF condition on the other see Figure 2 The first condition taught is the ON condition The Output ON and OFF conditions can...

Страница 5: ...ess and hold Dynamic button Hold remote line low to ground Display flashes dyn Arrow icon turns red TEACH Sensing Conditions Present Output ON OFF conditions while continuing to hold Dynamic button Present Output ON OFF conditions while continuing to hold remote line low to ground Return to RUN Mode Release Dynamic button Release remote line switch TEACH conditions acceptable Display flashes pass ...

Страница 6: ... extends 200 counts above and below the taught condition including 100 counts hysteresis All other conditions lighter or darker result in OFF output Sensing window sensitivity is adjustable using and buttons see Manual Adjust page 9 Window SET is most useful when a product may not always appear in the same place or when other signals may appear Window SET designates a sensing window with the Outpu...

Страница 7: ...st Sensor positions threshold slightly below the presented condition Sensor positions threshold slightly above the presented condition Darkest no signal Darkest no signal Most Light saturated signal Most Light saturated signal Darkest no signal Most Light saturated signal Condition Presented Output OFF Output OFF Output ON Output OFF Output ON Condition Presented Output OFF Output ON Condition Pre...

Страница 8: ...ter 60 seconds sensor returns to RUN mode Arrow icon turns green without changing settings T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button Remote dynamic static dynamic static dynamic static dynamic static dynamic static dynamic static Mode Threshold Offset counts above taught signal value Super High Speed 30 High Speed 22...

Страница 9: ...ing Threshold Fine tunes sensing sensitivity Press to increase press to decrease Sensing Window Adjusts sensing window size tolerance for the single point target condition Press to increase press to decrease Push Button Remote Result Manual Adjust Click to increase or click to decrease Not available with remote programming Display briefly flashes the threshold setpoint value as it is being changed...

Страница 10: ...ouble pulse the remote line to toggle between selections OFF No OFF Delay t 0 Clock icon OFF 2 to 100 ms OFF Delay t 2 t 5 t 10 t 15 t 20 t 30 t 40 t 60 t 80 or t100 Clock icon ON Click Static to save selection and advance to Display Single pulse the remote line to save selection and advance to Display Select Display Parameters Click Dynamic to toggle between selections Double pulse the remote lin...

Страница 11: ...mode quad click the remote line Indicator Arrow Icons 1 and 2 remain red Display shows Tracking Enabled option Track Enable Click Dynamic to toggle between selections Double pulse the remote line to toggle between selections Sets output 2 identical to output 1 Tracking disabled Display shows tr n Tracking enabled Display shows tr y Click Static to save selection and advance to Factory Default Sing...

Страница 12: ...or 2 PNP depending on model Output Rating 150 mA maximum load OFF state leakage current 10 µA at 24V dc ON state saturation voltage NPN 1 5V at 150 mA load PNP 2 5V at 150 mA load Output Protection Circuitry Protected against false pulse on power up and continuous short circuit Output Response Time Programmable 50 microseconds 200 microseconds 1 millisecond 2 5 milliseconds NOTE 1 second delay on ...

Страница 13: ...13 deep ø4 4 mm 0 18 thru 2x 3 5 mm 0 14 5 0 mm 0 20 8 6 mm 0 34 25 4 mm 1 00 16 0 mm 0 63 2 x ø3 3 mm 0 13 2x ø3 2 mm 0 13 2 5 mm 0 10 5 0 mm 0 20 M3 Hardware included Lock Washer 2 Flat Washer 2 Screws 2 Hex Nuts 2 Included Bracket Dimensions 61 3 mm 2 42 68 1 mm 2 68 Plastic Fiber Emitter Port Plastic Fiber Receiver Port 10 5 0 2 mm typ 0 41 Mounting Bracket included Slides Up to Release Fibers...

Страница 14: ...Temperature 40 to 90 C 40 to 194 F Voltage Rating 30V ac 36V dc Style Model Length Dimensions Pin out 6 Pin Straight PKG6Z 2 2 m 6 5 PKG6Z 9 9 m 30 6 Pin Right angle PKW6Z 2 2 m 6 5 PKW6Z 9 9 m 30 28 mm max 1 1 ø 10 mm max 0 4 20 mm 0 8 25 mm max 1 0 ø12 mm max 0 5 Brown Wire Gray Wire Pink Wire Blue Wire Black Wire White Wire Hookups NPN Output Models PNP Output Models bu 12 24V dc 1 2 Teach Gate...

Страница 15: ...P N 64154 rev F 15 D10 Expert Dual Discrete Outputs Banner Engineering Corp Minneapolis MN U S A www bannerengineering com Tel 763 544 3164 ...

Страница 16: ...s its products to be free from defects for one year Banner Engineering Corp will repair or replace free of charge any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or ...

Отзывы: