background image

D10 

Expert

 Dual Discrete Outputs

8   

 

P/N 64154 rev. F

 

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

Figure 9.  Single-Point Dark SET (Light 

Operate shown)

Sensor positions

window thresholds

≈10%

 from the

presented condition

Sensor positions 

threshold between

taught conditions

Threshold position

adjusted by

Manual Adjust

Threshold position

adjusted by

Manual Adjust

Sensor positions 

threshold between

taught conditions

Sensor positions

threshold slightly below

the presented condition

Sensor positions

threshold slightly above

the presented condition

Darkest

(no signal)

Darkest

(no signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Darkest

(no signal)

Most Light

(saturated

signal)

Most Light

(saturated

signal)

Condition

Presented

Sensing window size

adjusted by

Manual Adjust

Output OFF

Output OFF

Output OFF

Output ON

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Output OFF

Output ON

Condition

Presented

Output OFF

Output ON

Condition

Presented

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Push Button 

0.04 seconds ≤ “Click” ≤  0.8 seconds 

Remote Line

0.04 seconds ≤ T ≤  0.8 seconds 

Result

Access

 

SET 

Mode

•  Press and hold 

 

Static push button  
> 2 seconds

•  Single-pulse 

 

remote line

 
 

• Display flashes “

1st

• Arrow icon turns red

 
 

• Display flashes “

2nd

• Arrow icon turns red

SET 

Output 

OFF 

Condition

•  Present Output 

 

OFF condition

•  Five-click 

 

Static push  
button

•  Present Output 

 

OFF condition

•  Five-pulse remote line

Threshold Condition Accepted 

• Display flashes “

sngl

” then “

dr

” twice

•  Sensor returns to RUN mode with new settings
• Arrow icon turns green

Threshold Condition Unacceptable 

• Display flashes “

fail

” and returns to “

1st

” 

• Arrow icon remains red
•  After 60 seconds, sensor returns to RUN mode 

(Arrow icon turns green) without changing 
settings

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

Push Button

Remote

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

dynamic

static

Mode

Threshold Offset  

(counts above 

taught signal value)

Super High-Speed

30

High-Speed

22

High-Power

9

Super High-Power

6

Figure 10.  Dark SET Threshold Offset

Single-Point Dark SET

•  Sets a threshold slightly above the taught condition (see figure 9).
•  Any condition lighter than the threshold condition causes the output to change state.
• Threshold position is adjustable using  “+” and  “-” buttons (see Manual Adjust, page 9)
•  Recommended for applications where only one condition is known, for example a stable dark 

background with varying lighter targets.

A single sensing condition is presented, and the sensor positions a threshold slightly above 
the taught condition. When a condition lighter than the threshold is sensed, the output either 

turns ON or OFF, depending on the Light/Dark Operate setting (see Sensor Setup, page 10.)

Dark SET and Light/Dark Operate Selection

Dark SET teaches the Output OFF condition and forces the sensor into Light Operate (LO) 

mode. The sensor can be reconfigured to Dark Operate (DO) mode after the condition has 
been taught (see Sensor Setup, page 10).

Содержание D10 Expert

Страница 1: ... m or 9 m 6 5 or 30 cable or integral Pico style quick disconnect Sleek ultra slim 10 mm housing mounts to a standard 35 mm DIN rail U S Patent 5 808 296 9 m 30 cables are available by adding suffix W 30 to the model number of any cabled sensor e g D10DNFP W 30 A model with a QD connector requires a mating cable see page 14 WARNING Not To Be Used for Personnel Protection Never use these products a...

Страница 2: ... or when the target is absent OFF Delay Timing Selection Programmable OFF delay pulse stretcher 0 2 5 10 15 20 30 40 60 80 or 100 milliseconds Display Selection Discrete Output Raw signal value or excess signal Power Level Speed Selection Super High Speed SHS High Speed HS High Power HP Super High Power SHP Response 50 µs 200 µs 1 ms 2 5 ms Repeatability 25 µs 50 µs 75 µs 100 µs Maximum Range Fibe...

Страница 3: ...ess and hold the Static button for 2 seconds to cancel out of SETUP mode press and hold both the Static and Dynamic buttons for 2 seconds Output 2 The setpoint s for each output can be set independently of one another see Super High Speed Operation However the functional range available for output 2 is dictated by the automatic power and gain settings established for output 1 Whenever output 1 is ...

Страница 4: ...nual Adjust page 9 Static TEACH is the traditional setup method used when two conditions can be presented by the user The sensor locates a single sensing threshold the switchpoint midway between the two taught conditions with the Output ON condition on one side and the Output OFF condition on the other see Figure 2 The first condition taught is the ON condition The Output ON and OFF conditions can...

Страница 5: ...ess and hold Dynamic button Hold remote line low to ground Display flashes dyn Arrow icon turns red TEACH Sensing Conditions Present Output ON OFF conditions while continuing to hold Dynamic button Present Output ON OFF conditions while continuing to hold remote line low to ground Return to RUN Mode Release Dynamic button Release remote line switch TEACH conditions acceptable Display flashes pass ...

Страница 6: ... extends 200 counts above and below the taught condition including 100 counts hysteresis All other conditions lighter or darker result in OFF output Sensing window sensitivity is adjustable using and buttons see Manual Adjust page 9 Window SET is most useful when a product may not always appear in the same place or when other signals may appear Window SET designates a sensing window with the Outpu...

Страница 7: ...st Sensor positions threshold slightly below the presented condition Sensor positions threshold slightly above the presented condition Darkest no signal Darkest no signal Most Light saturated signal Most Light saturated signal Darkest no signal Most Light saturated signal Condition Presented Output OFF Output OFF Output ON Output OFF Output ON Condition Presented Output OFF Output ON Condition Pre...

Страница 8: ...ter 60 seconds sensor returns to RUN mode Arrow icon turns green without changing settings T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button Remote dynamic static dynamic static dynamic static dynamic static dynamic static dynamic static Mode Threshold Offset counts above taught signal value Super High Speed 30 High Speed 22...

Страница 9: ...ing Threshold Fine tunes sensing sensitivity Press to increase press to decrease Sensing Window Adjusts sensing window size tolerance for the single point target condition Press to increase press to decrease Push Button Remote Result Manual Adjust Click to increase or click to decrease Not available with remote programming Display briefly flashes the threshold setpoint value as it is being changed...

Страница 10: ...ouble pulse the remote line to toggle between selections OFF No OFF Delay t 0 Clock icon OFF 2 to 100 ms OFF Delay t 2 t 5 t 10 t 15 t 20 t 30 t 40 t 60 t 80 or t100 Clock icon ON Click Static to save selection and advance to Display Single pulse the remote line to save selection and advance to Display Select Display Parameters Click Dynamic to toggle between selections Double pulse the remote lin...

Страница 11: ...mode quad click the remote line Indicator Arrow Icons 1 and 2 remain red Display shows Tracking Enabled option Track Enable Click Dynamic to toggle between selections Double pulse the remote line to toggle between selections Sets output 2 identical to output 1 Tracking disabled Display shows tr n Tracking enabled Display shows tr y Click Static to save selection and advance to Factory Default Sing...

Страница 12: ...or 2 PNP depending on model Output Rating 150 mA maximum load OFF state leakage current 10 µA at 24V dc ON state saturation voltage NPN 1 5V at 150 mA load PNP 2 5V at 150 mA load Output Protection Circuitry Protected against false pulse on power up and continuous short circuit Output Response Time Programmable 50 microseconds 200 microseconds 1 millisecond 2 5 milliseconds NOTE 1 second delay on ...

Страница 13: ...13 deep ø4 4 mm 0 18 thru 2x 3 5 mm 0 14 5 0 mm 0 20 8 6 mm 0 34 25 4 mm 1 00 16 0 mm 0 63 2 x ø3 3 mm 0 13 2x ø3 2 mm 0 13 2 5 mm 0 10 5 0 mm 0 20 M3 Hardware included Lock Washer 2 Flat Washer 2 Screws 2 Hex Nuts 2 Included Bracket Dimensions 61 3 mm 2 42 68 1 mm 2 68 Plastic Fiber Emitter Port Plastic Fiber Receiver Port 10 5 0 2 mm typ 0 41 Mounting Bracket included Slides Up to Release Fibers...

Страница 14: ...Temperature 40 to 90 C 40 to 194 F Voltage Rating 30V ac 36V dc Style Model Length Dimensions Pin out 6 Pin Straight PKG6Z 2 2 m 6 5 PKG6Z 9 9 m 30 6 Pin Right angle PKW6Z 2 2 m 6 5 PKW6Z 9 9 m 30 28 mm max 1 1 ø 10 mm max 0 4 20 mm 0 8 25 mm max 1 0 ø12 mm max 0 5 Brown Wire Gray Wire Pink Wire Blue Wire Black Wire White Wire Hookups NPN Output Models PNP Output Models bu 12 24V dc 1 2 Teach Gate...

Страница 15: ...P N 64154 rev F 15 D10 Expert Dual Discrete Outputs Banner Engineering Corp Minneapolis MN U S A www bannerengineering com Tel 763 544 3164 ...

Страница 16: ...s its products to be free from defects for one year Banner Engineering Corp will repair or replace free of charge any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or ...

Отзывы: