background image

Specifications

Supply Voltage

10 V dc to 30 V dc

Consumption

0.7 A (at 10 V dc) to 0.2 A (at 30 V dc) maximum

Communication Interface

Main RS232 or RS422 full duplex: 2400 bit/s to 115200 bit/s

Auxiliary - RS232: 2400 to 115200 bit/s

Ethernet 10: 10/100 Mbit/s

Inputs

Input 1 (External Trigger) and Input 2 opto-isolated and polarity insensitive

Outputs

3 NPN/PNP/Push-Pull software selectable, reverse polarity and short circuit pro-

tected outputs available (2 Opto-isolated outputs instead if using TCNM-ACBB1)

Optical Features

See the Instruction Manual for details

LED Safety: LED emission according to EN 62471

Imager

1.3 MP: 1280 × 1024 pixels, SXGA, 60 frames/second

2.0 MP: 1600 × 1200 pixels, 45 frames/second

Construction

Aluminum, plastic window

Operating Conditions

Operating Temperature 11: 0 °C to +50 °C (+32 °F to +122 °F)

Liquid lens models Operating Temperature 11: 0 °C to +45 °C (+32 °F to +113 °F)

Storage Temperature: –20 °C to +70 °C (–4 °F to +158 °F)

90% maximum relative humidity (non-condensing)

Environmental Rating

IEC IP67 12

Parameter Storage

Permanent memory (Flash)

Other

Smart Teach Button (configurable via Barcode Manager), Beeper

Required Overcurrent Protection

WARNING: Electrical connections must be made by

qualified personnel in accordance with local and na-

tional electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per

the supplied table.

Overcurrent protection may be provided with external fusing or via Current Limit-

ing, Class 2 Power Supply.

Supply wiring leads < 24 AWG shall not be spliced.

For additional product support, go to 

www.bannerengineering.com

.

Supply Wiring (AWG)

Required Overcurrent Protection (Amps)

20

5.0

22

3.0

24

2.0

26

1.0

28

0.8

30

0.5

Certifications

Barcode Types

1-D and stacked

2-D

POSTAL

PDF417 Standard and Micro

PDF417

Code 128 (GS1-128)

Code 39 (Standard and Full

ASCII)

Code 32

MSI

Standard 2 of 5

Matrix 2 of 5

Plessey

Interleaved 2 of 5

Codabar

Code 93

Pharmacode

EAN-8/13-UPC-A/E (includ-

ing Addon 2 and Addon 5)

GS1 DataBar Family

Composite Symbologies

Data Matrix ECC 200

(Standard, GS1 and Direct

Marking)

QR Code (Standard and Di-

rect Marking)

Micro QR Code

MAXICODE

Aztec Code

Dotcode

Australia Post

Royal Mail 4 State Customer

Kix Code

Japan Post

PLANET

POSTNET

POSTNET (+BB)

Intelligent Mail

Swedish Post

FCC Statement

Modifications or changes to this equipment without the expressed written approval of Banner Engineering could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device

must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre-

quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in

a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

PC Requirements—Barcode Manager

Administrative rights are required to install the Barcode Manager software.

Operating System

Microsoft

®

 Windows

®

 operating system version 7, 8, or 10 13

Barcode Manager does not currently support Windows Embedded (often used in

industrial PCs and/or PLCs)

System Type

32-bit or 64-bit

Hard Drive Space

2 GB hard disk for 64-bit machines; 1 GB hard disk for 32-bit machines

Memory (RAM)

1 GB RAM

Processor

2.00 GHz or faster microprocessor

Screen Resolution

One 19-inch or larger monitor, optimized for 1280×1024 resolution

Third-Party Software

Web Browser: Google Chrome, Mozilla Firefox, Microsoft Internet Explorer, Opera,

etc.

Connection

100 Base-T Ethernet

10

The Ethernet interface supports application protocols: TCP/IP, EtherNet/lP, Modbus TCP, SLMP

11

High ambient temperature applications should use metal mounting bracket for heat dissipation.

12

IEC IP67 when correctly connected to IP67 cables with seals.

13

Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries.

ABR 7000

 

 

P/N 207633 Rev. C

7

Содержание ABR 7000

Страница 1: ...l Ethernet 1D and 2D ABR7109 MSE2 9 mm manual focus Multicolored DPM 2 ABR7112 RSE2 12 mm manual focus Red ABR7116 RSE2 16 mm manual focus Red ABR7106 RSE2 6 mm manual focus Red ABR7106 MSE2 6 mm manual focus Multicolored DPM 2 ABR71L9 RSE2 9 mm Liquid Lens Autofocus Red ABR71L9 MSE2 9 mm Liquid Lens Autofocus Multicolored DPM 2 ABR71L9 WPE2 9 mm Liquid Lens Autofocus White Polarized ABR72L9 RPE2 ...

Страница 2: ... a person s eye Mount open laser beam paths either above or below eye level where practical Terminate the beam emitted by the laser product at the end of its useful path Reference IEC 60825 1 2007 Section 8 2 CAUTION Never stare directly into the sensor lens Laser light can damage your eyes Avoid placing any mirror like object in the beam Never use a mirror as a retroreflective target Class 2 Lase...

Страница 3: ...4 Green Transmit Data of Auxiliary RS232 5 Pink External Trigger Input 1 B polarity insensitive 6 Yellow External Trigger Input 1 A polarity insensitive 7 Black ID NET network 8 4 Gray Output 2 NPN or PNP short circuit protected and software programmable 9 4 Red Output 1 NPN or PNP short circuit protected and software programmable 13 White Green Input Signal 2 A polarity insensitive 14 4 Brown Gre...

Страница 4: ... Aim The Aim function turns on the built in laser pointer aiming system to aid reader positioning Because the laser pointers are centered on the FOV use them to position the imager on the code The Aim LED blinks to indicate this state After a short delay this function also performs the Autofocus procedure for Liquid Lens Autofocus models See the Instruction manual for more details 1 Select a singl...

Страница 5: ...en used in industrial PCs and or PLCs 1 Download the latest version of Barcode Manager from www bannerengineering com 2 Navigate to and open the downloaded file 3 Run Barcode Manager_Setup exe to access the installation screen 4 Follow the onscreen installation procedure After the installation is complete the Barcode Manager entry is created under Start Programs Banner Engineering A desktop icon i...

Страница 6: ...e reader at the correct application reading distance 4 If needed focus the reader on the code 5 After the code is positioned click Pause to stop image acquisition Note If the image display area is too dark to see the images being captured drag the Gain and Exposure Time sliders to the right to increase visibility This will not affect Automatic Setup Figure 10 Gain and Exposure Time 6 Click Start A...

Страница 7: ...ode MAXICODE Aztec Code Dotcode Australia Post Royal Mail 4 State Customer Kix Code Japan Post PLANET POSTNET POSTNET BB Intelligent Mail Swedish Post FCC Statement Modifications or changes to this equipment without the expressed written approval of Banner Engineering could void the authority to use the equipment This device complies with PART 15 of the FCC Rules Operation is subject to the follow...

Страница 8: ...pair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PROD UCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRIC...

Отзывы: