6.3 Diagnostics Program
Emitter or receiver problems may be further diagnosed using the diagnostics routine,
which is included with the MINI-ARRAY software. Launch the program by selecting
Diagnostics...
under the
MINI-ARRAY
menu (see Figure 6-3), or press the
F2
key.
The
Diagnostics
screen (Figure 6-4) displays the type of each emitter and receiver
module (Board) and its functional status (State). If an error has occurred, the specific
problem beam (Channel) will be identified. Additionally, If there is a problem with an
emitter or receiver cable connection, a “No Response” message will be displayed.
The Diagnostics routine also displays the part number and date code of the controller,
which may be useful information if factory-assisted troubleshooting by telephone is
required.