Figure 5-22. MINI-ARRAY software: Retrieve PSF screen
Retrieving a PSF from Disk
To retrieve a filed PSF, select
File Retrieve PSF
. The
FileBox
subscreen will appear
(Figure 5-22). Select the desired PSF from the
File Name
list and then select
OK
or
press the Enter key. The selected PSF will load to the PSF Configuration screen and
can be loaded into the controller using the
Send PSF
command.
PSF Output Analysis
To view activity in the array in response to the currently loaded PSF, select
Execute.
The Measurement Output screen will appear (Figure 5-23). Select
Run.
The table will
display the status for the selected measurement mode(s), including the Present value,
and the High and Low values for the Run
period.
Select
Stop
to freeze the data. Select
Step
to initiate a single scan of the array. This
simulates a “snapshot” of what is viewed
by the array when
Step
is selected.
Use of the
Execute
command is
especially beneficial for testing the
response of a gated system.
Run
simulates the
Continuous
scanning
mode, and
Step
simulates a gate input
command.
To close the PSF Configuration screen,
select either
Quit
or
Exit.
Figure 5-23. MINI-ARRAY software: PSF Output Analysis
Controller Configuration