background image

www.banggood.com

https://www.banggood.com/Wholesale-Module-Board-c-2152.html

through the Micro USB data cable. The load current is adjusted to the

same current as the first step. Long press the “Next Page” button to

record the data, and the right indicator icon will stop blinking. After the

resistance test is completed, the data line resistance value is displayed.

Note: If the tester screen turns black after inserting the data cable in the

second step, it means that the pressure difference is too large, the tester

enters the 4.5V power-down state, and the load current needs to be

reduced, need to measurement from the first step. After the wire

resistance measurement is completed, the measurement is restarted

after the tester is powered on the next time.

Short press the "Next" button to switch to the main interface

(voltage curve interface):

Main interface

(voltage curve interface):

This interface is voltage measurement waveform diagram. It

automatically changes the range within the range of 4.5-24V

measurement and displays voltage fluctuations in real time.

Содержание A3

Страница 1: ...5Ω 9999 9Ω Temperature Measurement Range 10 C to 100 C 0 F to 200 F Screen brightness setting 0 5 Voltage curve range 4 5V 24V Voltage measurement resolution 0 01V Current measurement resolution 0 001A Voltage measurement accuracy 0 2 Current measurement accuracy 0 8 Time measurement range 0 99 hours 59 minutes 59 seconds Temperature measurement error 3 C 6 F Delay off screen time 0 9 minutes Curr...

Страница 2: ...www banggood com https www banggood com Wholesale Module Board c 2152 html ...

Страница 3: ...6 1 44 inch color LCD display 7 Bluetooth indicator A3 B version only waiting for pairing fast blinking paired connection succeeds from blinking to long bright after connection the display shows the Bluetooth logo Three operating modes Direct use with USB power supply PC software control download link http files banggood com 2018 05 PC softwareV1 2 zip Mobile APP online control download link http ...

Страница 4: ...www banggood com https www banggood com Wholesale Module Board c 2152 html ...

Страница 5: ...no load access must be guaranteed Keep pressing and holding the key to move shadow in turn Release the key at the selected item to execute the setting If the button is still not released after three items are displayed it means that no function is performed and will exit the hidden option interface Main interfaceⅠ main measurement interface 1 Voltage measurement 2 Current measurement 3 Cumulative ...

Страница 6: ...y is temporarily saved when the power is dropped The next time the power is switched on it will flash to remind the last capacity When the accumulative capacity exceeds 1mAh the last data will be erased automatically and the accumulations will start again Under the selected condition of the data group number long press the Help key to clear the accumulated capacity value and accumulated energy val...

Страница 7: ...ext button to switch to the main interface Ⅲ data record interface Main interface Ⅲ data record interface Accumulated capacity Cumulative energy value Time display cumulative time of current load Stop current REC indicates the recording status red REC means stop and green REC means recording After power on when the current is greater than the stop current the system begins to record capacity and e...

Страница 8: ...ent value of the tester directly connected to the power supply 2 The test instrument is connected to the voltage current value when the data line is connected to the power supply R DATA wire resistance This product s interface can be used to measure the data line resistance value the operation steps The first step the tester directly connect the power supply adjusts the appropriate load current Re...

Страница 9: ...e in the second step it means that the pressure difference is too large the tester enters the 4 5V power down state and the load current needs to be reduced need to measurement from the first step After the wire resistance measurement is completed the measurement is restarted after the tester is powered on the next time Short press the Next button to switch to the main interface Ⅴ voltage curve in...

Страница 10: ...urrent curve interface This interface is the current measurement waveform diagram It automatically changes the range within 0 00A 3 00A measurement range and displays current fluctuations in real time Short press Next button to switch to the main interface Ⅶ setting interface Main interface Ⅶ setting interface Delay off screen time Screen brightness Temperature unit switching ...

Страница 11: ...s the value of a total of 10 values in the 0 9 cycle change in which 0 is the long bright Long press Next button to enter the screen brightness settings select corresponding number short press to change the size of the number the greater the number the brighter the screen a total of 6 settings Long press the Next button to enter the temperature unit switch select corresponding number short press t...

Отзывы: