Replacement of modules
Replacement of modules
Replacement of contrast screen
Actions before dismantling the PDP
Before dismantling the PDP - disconnect the mains supply and wait minimum
1 minute for the electolytic capasitors to discharge.
Connect ESD-mat.
After replacing module(s) in the PDP follow the test and adjustment procedure as
described in “Test and adjustment after replacement of module(s)” on page 1.14.
NOTE
Internal cables in the PDP.
Please show precaution when disconnecting cables from sockets.
Replacement of modules
Follow the instructions described on page:
8.1 - 8.5
PDP in service position
8.7 - 8.19
for selected PCB
Replacement of contrast screen
Use white gloves to avoid smudging the contrast screen.
Use only the micro fibre cloth, part no. 3375706 to clean the PDP.
Do not use any kind of cleaning detergents on the PDP.
Follow the instructions described on page:
8.1 - 8.5
PDP in service position
8.6
Remove contrast screen and plasma frame
Replacement of modules, English 1.11