![Bang & Olufsen BeoVision 5 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/bang-and-olufsen/beovision-5/beovision-5_service-manual_3054016032.webp)
1.32 Service mode, English
Service mode, English 1.33
Monitor information
Monitor information menu, press
1
- Software version numbers.
61IC5 (STB-C) TABLE indicates the version of the STB-C conversion codes.
Option
Option 0 = The IR reciever of the TV is disconnected.
Option 1 = The TV and the Audio system (BeoLink system) are placed in the same
room.
Option 2 = The TV and the Audio system (BeoLink system) are placed in different
rooms.
Important!
When replacing the electrical chassis including PCB6 Main microcomputer, to
avoid loss of data the old EEPROM 6IC6 must be moved to the new PCB6.
If error codes occurs, please write them down and let them follow the faulty part
for repair. After that clear the error codes. This is done by pressing
GO
in the
Monitor information menu.
Survey of Error Codes
Access to Service Mode
Select TV MENU and select Setup.
Press
0 0 GO
within 3 seconds.
Reading the error code
To read an error code from the television you must access the Service
Mode. Then
select
MONITOR -> MONITOR INFORMATION.
If the television has registered an
error, the error code will be shown in this menu under ERROR.
Monitor information
06 IC3
(AP)
: SW
6.0
06 IC2
(IOP)
: SW 20.0
61 IC5
(STB-C)
: SW
3.1
61 IC5
(STB-C)
: TABLE 1.6
32 IC607 (DSM)
: SW 0.75d
EEPROM ver.
004
Type no.
8912
Item no.
1891232
Serial no.
12345678
Master code
Stored
Option
1
Clock error
....
.....
Last TV error
....
.....
....
.....
....
.....
....
.....
....
.....
Last ML/SL error
..