1.18 Plasma Display Panel self-check, English
ID
IIC1
IIC2
IIC3
D
J/
DG
Z
IC9702
IC9009
IC9019
IC9151
IC9605
IC9709
IC1001
IC3003
IC3004
OK H21
OK H61
OK H62
OK H53
IC9305
- - -
IC9455
OK H55
OK H56
OK H52
IC2401
OK H54
OK H51
OK H63
OK H64
IC3005
IC3006
OK H65
OK H66
Plasma Display Panel (PDP) self-check
The self-check checks the status of the circuits connected to the IIC bus
-
Refer to illustrations for:
- Placement of black self-adhesive tape on the PDP.
- Placement of buttons on NN remote control.
-
Remove front frame and front cloth, see illustrations page 8.1.
-
Remove the black self-adhesive tape on the PDP. See
1.
-
Switch on BeoVision 5-42.
-
Enter self-check mode.
Press button
"B"
on the PDP and at the same time button
OFF TIMER
on the
remote control. See
1 and
2.
The display will show “:-”, while the self-check is performed.
-
Result of self-check. See
3.
“OK”
No fault
“- -”
Fault in or missing circuit
-
Exit self-check mode.
Press
“Standby”
on NN remote control and thereafter press
Standby
on Beo4.
-
Mount the black self-adhesive tape on the PDP.
-
Mount the front cloth and front frame.
1
2
3
B
Standby
+
+
_
VOL
R
LED