Service menu 3.7
EP 1+2 = 0005
RMP PAUSE RELEASE
Use EP3
EP 3 = 0A
RMP PAUSE RELEASE TIMEOUT
No error
EP 1+2 = 0006
RMP WIND
Use EP3
EP 3 = 0B
RMP WIND TIMEOUT
No error
EP 1+2 = 0007
RMP REWIND
Use EP3
EP 3 = 0C
RMP REWIND TIMEOUT
No error
EP 1+2 = 0008
RMP RESET ALL
Use EP3
EP 3 = 0D
RMP RESET TIMEOUT
No error
EP 1+2 = 0009
RMP MUTE
Use EP3
EP 3 = 0E
RMP MUTE TIMEOUT
No error
EP 1+2 = 000A
RMP DEMUTE
Use EP3
EP 3 = 0F
RMP DEMUTE TIMEOUT
No error
EP 1+2 = 000B
RMP RELEASE WIND REWIND
Use EP3
EP 3 = 10
RMP RELEASE WIND REWIND TIMEOUT
No error
EP 1+2 = 000C
RMP MARK A
Use EP3
EP 3 = 11
RMP MARK A ERROR TIMEOUT
No error
EP 1+2 = 000D
RMP MARK B
Use EP3
EP 3 = 12
RMP MARK B ERROR TIMEOUT
No error
EP 1+2 = 000E
RMP RELEASE AB
Use EP3
EP 3 = 13
RMP AB REPEAT ERROR TIMEOUT
No error
EP 1+2 = 000F
RMP GOTO ABS TIME
No error
EP 1+2 = 0012
RMP FOLDER STEP
Use EP3
EP 3 = 1C
RMP FOLDER STEP TIMEOUT
No error
EP 1+2 = 0023
RMP SHUTDOWN MEDIA
No error
EP 3 = 1D
RMP SHUTDOWN MEDIA TIMEOUT
DVDM, SW bug check for Master Unit
SW update
EP 1+2 = 0024
RMP QUEUE NEXT TRACK
No error
EP 3 = 06
RMP INVALID TRACK NO
No error
EP 3 = 07
RMP TRACK NOT FOUND TIMEOUT
DVDM, SW bug check for Master Unit
SW update
EP 1+2 = 0105
RMP START DRIVER
Use EP3
EP 3 = 22
RMP START DRIVER TIMEOUT
DVDM
EP 3 = 00
RMP NO RMP ERROR
No error
EP 3 = 17
RMP COMMUNICATION ERROR
SW bug, check for Master Unit/AP SW
update
EP 3 = 1E
RMP DOORS NOT CLOSED
Check door and loader mechanics, SW
bug check for Master Unit SW update
EP 3 = 20
RMP DRIVER NOT STARTED
SW bug, check for Master Unit/AP SW
update
EP 3 = 21
RMP BUSY
No error
41
RMP TRANSMIT QUEUE FULL
SW bug, check for AP SW update
42
RMP DD UNKNOWN COMMAND
SW bug, check for AP SW update
50
OUT OF DISPLAY REPOSITORIES
SW bug, check for AP SW update
51
DISPLAY REPOSITORY OVERRUN
SW bug, check for AP SW update
60
CABLE DATA UNSTABIL
Check connection between Socket Unit
and Master Unit, AV Panel, Top interface,
interface cable.
61
PING PONG FAILURE
Check connection between Socket Unit
and Master Unit, AV Panel, Top interface,
interface cable.
62
TOP RETRANS FAILED
Check connection between Socket Unit
and Master Unit, AV Panel, Top interface,
interface cable.
70
DOORS BLOCKED OPENING
Check doors mechanical
71
DOORS BLOCKED CLOSING
Check doors mechanical
72
DOORS NOT READY ERROR
Check doors mechanical. Check for AP
SW update
73
SOF DISP EXCEED SOF DISP DD TELEGRAM TYPE
SW bug, check for AP SW update
74
OUT OF DISP DD TELEGRAMS
SW bug, check for Master Unit SW
update
75
TOP ERROR
Содержание BeoCenter 2 MK II
Страница 10: ...2 ...
Страница 22: ...3 12 ...
Страница 24: ...4 ...
Страница 35: ...Replace DVD PCB 5 11 77P901 Remove plugs Remove screw 1x TX6 77P102 77P101 77P103 77P951 Located on backside ...
Страница 43: ...Servicetest position 5 19 5 3 BeoCenter 2 in service position Placement of magnetic tester ...
Страница 54: ...6 ...
Страница 55: ...7 1 Overall block diagram Overall block diagram 7 1 7 1 ...
Страница 56: ...7 2 7 2 7 2 ...
Страница 67: ......
Страница 68: ...Bang Olufsen DK 7600 Struer Denmark Phone 45 96 84 11 22 Fax 45 97 85 39 11 3538050 11 06 ...