3.4 Service menu
EP 1 = 07
IIC1 2 SLAVE TRANS BUF ERR
Use EP2
EP 1 = 08
IIC1 2 ICB ERROR
Use EP2
EP 2 = D0
CLOCK IIC ADDR
(IC162) Av Panel
EP 2 = 88
A ENG IIC ADDR
(IC300) Analog Sound Engine
EP 2 = 22
ST RDS IIC ADDR
(IC402) AM/FM Tuner
EP 2 = C6
ST TUNER IIC ADDR
(IC200) AM/FM Tuner
EP 2 = C4
ST PLL IIC ADDR
(IC200) AM/FM Tuner
EP 2 = 8C
ST STEREO DECODER IIC ADDR
(IC300) AM/FM Tuner
EP 2 = 7E
ST LPC IIC ADDR
(IC401) AM/FM Tuner
EP 2 = A0
ST EEPROM ADDR
(IC203) AM/FM Tuner
EP 2 = EA
DAB TUNER ADDR
DAB Tuner
EP 3 = 00
IIC1 BUS ID
IIC bus no. for e.g. measurements
EP 3 = 01
IIC2 BUS ID
IIC bus no. for e.g. measurements
02
Eeprm addr
EEPROM WRITE ERROR
Default settings or replace EEPROM
03
Eeprm addr
EEPROM READ ERROR
Default settings or replace EEPROM
04
Eeprm addr
EEPROM READ ERROR ONLY FF
Default settings or replace EEPROM
0B
Eeprm addr
EE WRITE OVERFLOW
Default settings or replace EEPROM
0C
Eeprm addr
EE CONTROL INIT FAIL
Default settings or replace EEPROM
0D
Eeprm addr
EE CONTROL CALLOC FAIL
Default settings or replace EEPROM
20
MLSL STATUS ERROR
EP 1 = 20
CONFIG IMPOSS
ML installation, Analog Sound Engine, or
Av Panel
EP 1 = 10
LINK TIED UP
ML installation, Analog Sound Engine, or
Av Panel
EP 1 = 08
LINK TIED DOWN
ML installation, Analog Sound Engine, or
Av Panel
EP 1 = 04
LINK OK
No error
EP 1 = 02
ML CURRENT MASTER
No error
EP 1 = 22
CONFIG IMPOSS CURRENT MASTER
ML installation, Analog Sound Engine, or
Av Panel
EP 1 = 12
LINK TIED UP CURRENT MASTER
ML installation, Analog Sound Engine, or
Av Panel
EP 1 = 0A
LINK TIED DOWN CURRENT MASTER
ML installation, Analog Sound Engine, or
Av Panel
EP 1 = 06
LINK OK AND CURRENT MASTER
No error
21
MLSL TIMEOUT ERROR
No error
22
MLSL TX BUF FULL TLG NOT SEND
No error
23
ML KEY LOST KEY REPAIRED
No error
24
EXTERNAL COMMUNICATION NOT ALLOWED IN
PREPROJECT
No error
25
LSL FORMAT ERROR
EP 1 = 01
LSL2 ERROR ID
Defect Power link. Connection, Analog
Sound Engine or Av Panel
27
LSL TX IMPOSS
EP 1 = 01
LSL2 ERROR ID
Defect Power link. Connection or Av
Panel
28
LSL LINK TIED UP
EP 1 = 01
LSL2 ERROR ID
Defect Power link. Connection, Analog
Sound Engine or Av Panel
29
LSL LINK TIED DOWN
EP 1 = 01
LSL2 ERROR ID
Defect Power link. Connection, Analog
Sound Engine or Av Panel
2A
GENERIC ICB ERROR
µP H8 Module
2B
ICB L7 TIMEOUT
ML installation, Analog Sound Engine, Av
Panel, or uP H8 Module
2C
ICB L7 ILLEGAL TIMEOUT
µP H8 Module
2D
ICB L7 OUT OF REPOSITORIES
µP H8 Module
2E
ICB L7 ILLEGAL L7 ACK
µP H8 Module
2F
ICB L7 ACKNOWLEDGE UNEXPECTED
µP H8 Module
30
ICB L7 READ RESPONSE UNEXPECTED
µP H8 Module
31
ICB L7 ILLEGAL RESOURCE TYPE
µP H8 Module
Содержание BeoCenter 2 MK II
Страница 10: ...2 ...
Страница 22: ...3 12 ...
Страница 24: ...4 ...
Страница 35: ...Replace DVD PCB 5 11 77P901 Remove plugs Remove screw 1x TX6 77P102 77P101 77P103 77P951 Located on backside ...
Страница 43: ...Servicetest position 5 19 5 3 BeoCenter 2 in service position Placement of magnetic tester ...
Страница 54: ...6 ...
Страница 55: ...7 1 Overall block diagram Overall block diagram 7 1 7 1 ...
Страница 56: ...7 2 7 2 7 2 ...
Страница 67: ......
Страница 68: ...Bang Olufsen DK 7600 Struer Denmark Phone 45 96 84 11 22 Fax 45 97 85 39 11 3538050 11 06 ...