7. Maintenance 

 
 

For proper functioning of the boot elevator type “David 2” it is important to 
have regular maintenance work done. Comply with the schedule below. 
Never do work on the boot elevator type “David 2” if you do not have the 
required knowledge and authority. 

 
 

 

MAINTENANCE SCHEDULE 

 

Maintenance operation 

 

Maintenance frequency 

Check the condition of the hoisting cord. 
Please note: when the cord is frayed due to wear, 
you should contact the supplier to have the cord 
replaced!! 

Each time the elevator is used 

General maintenance 

Every 12 months 

 

 

Checking the hoisting cord: 

Take the switch in  your hand, hold the hoisting cord taut and unroll the cord 
completely.  
Check the cord for wear.  
In case the Kevlar of the cord (inner core) is visible, you should contact the supplier 
immediately to have the hoisting cord replaced. 

 

 

Please note ! that during hoisting the motor turns to the right in 
the left-sided version or to the left in the right-sided version, as 
a result of which the hoisting cord is wound up at the rear side 
of the drum wheel. 

Содержание David 2

Страница 1: ...David 2 User Manual Revised 29 03 2005...

Страница 2: ...duction 5 Safety regulations 5 Use according to intended use 5 Safety provisions 5 Warnings concerning the use of boot elevator type David 2 5 4 Product 6 4 1 The composition of boot elevator type Dav...

Страница 3: ...find this symbol next to all instructions and regulations which relate to your safety and the safety of others You will find this symbol next to important instructions and information to ensure smooth...

Страница 4: ...pe number 5025 Manufacturer B S Auto Aanpassing Dimensions Platform 180x150 mm Height elevator 1000 mm Weight 7 6 Kg Electrical data Connection voltage 12 V Nominal current 3 A Quiescent current 0 mA...

Страница 5: ...s resulting from use the elevator was not intended for The boot elevator type David 2 is built according to the latest technology and meets the legal safety regulations Nevertheless from use of the bo...

Страница 6: ...tilted by 2 right manners 1 the elevator arm can be tilted with the operating lever 5 see figure 1 2 the elevator arm can be tilted by lifting the elevator arm in vertikal direction and it can be plac...

Страница 7: ...hose cases where the installation is done by a third party or by a company that buys the elevator from B S Hoorn the mounting manual should be used when building in and installation takes place This m...

Страница 8: ...chair with the button 8 Remove the hook 9 Tilt the elevator using the operating lever or lift the elevator in vertikal direction and put the elevator arm on top of the wheelchair 10 Close the boot lid...

Страница 9: ...r you should contact the supplier to have the cord replaced Each time the elevator is used General maintenance Every 12 months Checking the hoisting cord Take the switch in your hand hold the hoisting...

Страница 10: ...e Replace fuse and check for any electrical malfunctions Elevator does not hoist Fuse is OK but the motor is not running Check the connections for reliability or contact your supplier Elevator does no...

Страница 11: ...11...

Страница 12: ...12...

Отзывы: