Software • BIOS options
Chapter 4 Software
Automation PC 510 User's Manual V 1.01
77
1.4.2 System unit features
InsydeH2O Setup Utility Rev. *
OEM Features
Adjust the brightness of
the local panel.
System Unit Features
Device ID:
0000B4CB
Compatibility ID:
0000
Vendor ID:
00000000
Hardware Revision:
A0
Serial number:
B4CB0168435
Product name:
5PP520.0573-01
Hardware Number:
00201849
Parent Device ID:
FFFFFFFF
Parent Compatib. ID:
FFFF
User Serial ID:
Not defined
Display (0) Brightness:
<Auto>
LPC Devices
Statistical Values
Temperature Values
F1
F9
Esc
Enter
F10
Help Select Item
Change Values Setup defaults
Exit Select Menu
Select SubMenu
Save and Exit
F5/F6
Image 29: US15W OEM Features - System Unit Features
BIOS setting
Meaning
Setting options
Effect
Device ID
Displays the device code of the Power Panel de-
vice
None
-
Compatibility ID
Displays the version of the device within the same
B&R device code. This ID is needed for Automa-
tion Runtime.
None
-
Vendor ID
Displays the Vendor ID
None
-
Hardware Revision
Displays the system unit hardware revision
None
-
Serial Number
Displays the B&R serial number
None
-
Product Name
Displays the B&R model number
None
-
Hardware Number
Displays the system unit hardware number
None
-
Parent Device ID
Displays the manufacturer number
None
-
Parent Compatib. ID
Displays the manufacturer ID
None
-
User Serial ID
Displays the user serial ID. This 8-digit hex value
can be freely assigned by the user (e.g. to give
the device a unique ID) and can only be changed
with using the "B&R Control Center" via the ADI
driver.
None
-
Auto
The optimal brightness is automatically config-
ured using the factory settings. A brightness val-
ue between 100% and 0% is set.
Display (0) Brightness
1)
Option for setting the backlighting of the display.
0%, 10%, 20%, 30%,
40%, 50%, 60%, 70%,
80%, 90%, 100%
Manual setting of the desired brightness within
factory settings limits.
LPC devices
Configuration of the LPC Devices.
Enter
Opens the submenu
Statistical values
Displays the statistical values.
Enter
Opens the submenu
See " Statistical values" on page 79
Temperature values
Displays the current temperature values.
Enter
Opens the submenu
See " Temperature values" on page 80
Table 82: US15W OEM Features - System Unit Features setting options
1)
This setting is only available for PP500 system units.