![B&R 8LS 3 Series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/bandr/8ls-3-series/8ls-3-series_user-manual_3098713041.webp)
Technical data
8LS...-3 user's manual V2.50
41
2.12.3 Power dissipation
Power from the servo motors is dissipated via the motor flange and the surface of the motor. The following factors
are important to ensure optimal heat dissipation:
•
Thermally open installation
•
Free convection
The motor data specified for the nominal operating point apply to a motor installed in a thermally open system. The
dimensions of the flange plates used for the measurement are shown in the table below.
Generally speaking, the larger the flange, the better the heat dissipation.
Size
Dimensions [mm]
Material
8LSx2, 8LSAA, 8LSx3
250 x 250 x 6
Aluminum
8LSx4, 8LSx5, 8LSx5A/B/C
350 x 350 x 12
Aluminum
8LSx6, 8LSx7
495 x 495 x 15
Aluminum
8LSx8
ø 450 x 20
Steel
8LSO9, 8LSP9
350 x 395 x 19
Steel