Installation and connection
8LS...-3 user's manual V2.50
283
5.5.4.2 Motors with terminal box (8LSO9 / 8LSP9)
The
encoder connection
is straight and facing the connection direction.
The speedtec is used for resolvers and the springtec system is used for EnDat 2.2.
The size of the
power connections
depends on the motor power. The motor phases U
V W are connected to M10 (M12 for 8LSO96.ee022ffgg-h and 8LSP96.ee022ffgg-h) and
secured with threaded nuts. The required nuts and washers are included in delivery.
The
terminal box opening
is designed with an M50x1.5 internal thread.
Note:
For the terminal box opening, use an EMC cable gland where the cable gland or the cable braided
shield ground connection covers the full 360°.
The
temperature sensor
must be connected accordingly with a red cable for T+ and a white cable for T-.
Two free M12 threaded holes are available for the
ground connection
.