![B&R 5PP551.0573-00 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/bandr/5pp551-0573-00/5pp551-0573-00_user-manual_460457170.webp)
Software • BIOS options
170
Power Panel 500 User's Manual V 1.00
BIOS setting
Meaning
Setting options
Effect
Info:
To operate the processor within the
specified values, we recommend
not changing the default setting
(TM1 and TM2).
TM1 and TM2
Intel Thermal Mode 1 and 2 enabled.
If the CPU reaches excessive temper-
atures, TM1 reduces the processor
speed by 50% and TM2 activates the
Intel SpeedStep technology.
Enabled
Enables this function.
Use XD Capability
This option is a safety feature that pro-
tects specific data regions of the system
memory from potentially damaging code.
Disabled
Disables this function.
Enabled
If the function is enabled, a virtual ma-
chine can use the additional hardware
capacity.
VT Support
Option for activating or deactivating a vir-
tual machine.
Info:
You must restart in order to apply
changes made to this setting.
Disabled
Disables this function.
Enabled
Enables this function.
SMRR Support
The SMRR (System Management Range
Register) limits cacheable references of
addresses in SMRAM in order to keep
the code running in SMM (System Man-
agement Mode).
In some circumstances, an intruder who
is loggeg on as administrator could con-
figure the Intel processor to gain access
to the SMM. Implementation of SMRR re-
duces this risk of unauthorized access.
Disabled
Disables this function.
Enabled
Enables this function.
The processors are run at different fre-
quencies, thereby saving energy.
C-States
This setting allows the operating system
to set processor clock rates on its own,
thereby saving energy.
Disabled
Disables this function.
Both processors are run at the same
frequency.
Enabled
Enables this function.
Enhanced C-States
2)
This setting allows the operating system
to set processor clock rates on its own,
thereby saving energy.
Disabled
Disables this function.
Enabled
If ICH receives a Bus Master request,
then the system changes from C3/C4
state to C2 state and the Bus Master is
automatically activated.
C-State Pop Up Mode This setting makes it possible to de-
tect Bus Master requests and to assign
processor clock frequencies. This can be
done to save energy.
Disabled
Bus Master data transfer is a Break
Event and ICH will attempt to return to
the C0 state.
Enabled
If ICH does not receive a Bus Master
request, then the system will be set
back to C3/C4 state.
C-State Pop Down
Mode
3)
This setting makes it possible to de-
tect Bus Master requests and to assign
processor clock frequencies. This can be
done to save energy.
Disabled
ICH will not attempt to automatically re-
turn to C3/C4 state.
Enabled
Enables this function.
CPU voltage is reduced and the Memo-
ry Cache is turned off.
Hard C4E
4)
Power Management for the Intel Atom
processor - Enhanced C4 support.
Disabled
Disables this function.
Enabled
Enables this function.
The internal CPU voltage is reduced
(can also be 0 V).
Enable C6
Power Management for the Intel Atom
processor - C6 support.
Disabled
Disables this function.
Table 92: US15W Power - Advanced CPU Control setting options
Содержание 5PP551.0573-00
Страница 2: ...2 Power Panel 500 User s Manual V 1 00...
Страница 4: ...4 Power Panel 500 User s Manual V 1 00...
Страница 5: ...Power Panel 500 User s Manual V 1 00 5 Appendix A...
Страница 40: ...Technical data Entire device 40 Power Panel 500 User s Manual V 1 00 2 4 11 Mode Node switches...
Страница 210: ...Accessories CompactFlash cards 210 Power Panel 500 User s Manual V 1 00 3 3 6 Benchmark...
Страница 253: ...Power Panel 500 User s Manual V 1 00 253...