Installation and wiring
5.2 Automation Panel 9x3 - Installation
The Automation Panel 9x3 is installed in the installation cutout using retaining clips. The number of retaining clips
depends on the panel used.
The thickness of the wall or cabinet plate must be between 1 mm and 6 mm.
A 2.5 mm hex socket screwdriver is needed to tighten and loosen the screws on the retaining clips. The maximum
tightening torque for the retaining clips is 1 Nm.
The device must be installed on a flat, clean and burr-free surface since tightening screws on an uneven area can
result in damage to the display or the ingress of dust and water.
Procedure
1. Check whether the supplied mounting screws (1) are screwed into the retaining clips (2). If this is not the
case, the mounting screws must be screwed into the retaining clips using a 2.5 mm hex screwdriver (view A).
The mounting screws are only permitted to be screwed in to the point where they do not project beyond the
retaining clip (view B).
(2)
(1)
AA
B
2. Insert the device into the front side of the smooth, flat installation cutout. The dimensions for the cutout can
be found in section
"Installation diagrams" on page 27
3. Install the retaining clips on the device. To do this, insert all retaining clips into the recesses (marked with
orange circles) on the device. The number of retaining clips may vary depending on the panel. For the exact
number of retaining clips, see section
"Installation diagrams" on page 27
.
4. Secure the retaining clips to the wall or control cabinet panel (1) by alternately tightening the mounting screws
with a 2.5 mm hex screwdriver. The tightening torque for optimal sealing should be max. 1 Nm.
1 - 6 mm
(1)
Automation Panel 9x3 User's manual 2.01
73