![B&R Industries MASDL3CON-ENG Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/bandr-industries/masdl3con-eng/masdl3con-eng_user-manual_460497043.webp)
Accessories
SDL3 Converter User's manual V 2.00 Translation of the original documentation
43
10.3.3 SDL cables with 45° connector
10.3.3.1 5CASDL.0xxx-01
10.3.3.1.1 General information
5CASDL.0xxx-01 SDL cables with 45° connector are designed for use in fixed installations.
Caution!
The cable is only permitted to be connected/disconnected when the power is switched off.
10.3.3.1.2 Order data
Model number
Short description
Figure
SDL cable - 45° connector
5CASDL.0018-01
SDL cable - 45-degree connector - 1.8 m
5CASDL.0050-01
SDL cable - 45-degree connector - 5 m
5CASDL.0100-01
SDL cable - 45-degree connector - 10 m
Table 11: 5CASDL.0018-01, 5CASDL.0050-01, 5CASDL.0100-01 - Order data
10.3.3.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
5CASDL.0018-01
5CASDL.0050-01
5CASDL.0100-01
General information
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
1)
DNV GL
Temperature:
B
(0 - 55°C)
Humidity:
B
(up to 100%)
Vibration:
A
(0.7 g)
EMC:
B
(bridge and open deck)
2)
GOST-R
Yes
Cable construction
Wire cross section
28 AWG
24 AWG
Shield
Individual cable pairs, entire cable
Complete shielding
Tinned copper braiding, optical coverage > 85%
Outer jacket
Material
PVC
Color
Black
Connector
Type
2x DVI-D (24+1), male
Connection cycles
100
Contacts
Gold-plated
Mechanical protection
Metal cover with crimped strain relief
Locating screw tightening torque
Max. 0.5 Nm
Electrical characteristics
Conductor resistance
24 AWG
-
≤93 Ω/km
28 AWG
≤237 Ω/km
-
Insulation resistance
Min. 10 MΩ/km
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Mechanical properties
Dimensions
Length
1.8 m ±30 mm
5 m ±50 mm
10 m ±100 mm
Diameter
Max. 9 mm
Max. 11.5 mm
Table 12: 5CASDL.0018-01, 5CASDL.0050-01, 5CASDL.0100-01 - Technical data