Accessories
38
SDL3 Converter User's manual V 2.00 Translation of the original documentation
Model number
5CASD3.
0030-00
5CASD3.
0050-00
5CASD3.
0100-00
5CASD3.
0150-00
5CASD3.
0200-00
5CASD3.
0300-00
5CASD3.
0500-00
5CASD3.
1000-00
Conductor resistance
≤290 Ω/km
≤75 Ω/km
Wave impedance
100 ±5 Ω (at 100 MHz)
Transfer properties
Category 6A / Class EA up to 500 MHz per ISO/IEC
11801 (EN 50173-1), ISO/IEC 24702 (EN 50173-3)
Category 7 / Class F up to 600 MHz
per ISO/IEC 11801 (EN 50173-1),
ISO/IEC 24702 (EN 50173-3)
Insulation resistance
≥500 MΩ/km
≥5 GΩ/km
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Flame-retardant
IEC 60332-1-2
Oil and hydrolysis resistance
EN 60811-2-1 (90°C / 7x24 h)
Degree of protection per EN 60529
Cables
IP20
RJ45 connector
IP20, only when properly connected
Ambient conditions
Temperature
Storage
-40 to 70°C
Fixed installation
-40 to 70°C
Flexible installation
-40 to 70°C
-10 to 50°C
Mechanical properties
Dimensions
Length
3 m
5 m
10 m
15 m
20 m
30 m
50 m
100 m
Diameter
6.7 mm
8.3 mm
Bend radius
Fixed installation
≥5x diameter
≥4x diameter
Flexible installation
≥10x diameter
≥8x diameter
Weight
250 g
500 g
700 g
950 g
2150 g
3500 g
6950 g
Tension
In operation
≤70 N
≤110 N
During installation
≤70 N
≤110 N
Table 8: 5CASD3.0030-00, 5CASD3.0050-00, 5CASD3.0100-00, 5CASD3.0150-00,
5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Technical data
1)
Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
At 20°C ambient temperature.
10.3.1.1.4 Bend radius specification
Connector
Bend radius
C
on
ne
ct
or
Figure 8: SDL3/SDL4 - Bend radius specification
10.3.1.1.5 Dimensions
Length
Figure 9: 5CASD3.xxxx-00 - Dimensions