Wireless charging system 600W specification

For 12V・24V・

48V

 battery

・For the transmission distance and center off-set between the heads

Set the allowable misalignment of the passive head and the active head within the following ranges.
If the product is used outside the range, you may or equipment degradation of transmission efficiency may be 
damaged. Also, it is not possible to combine a standard head and a long distance head.

G

Direction

Distance

G

0 ~ 20mm

X

± 10mm

Y

± 15mm

X 軸方向

Y 軸方向

X 軸方向

Y 軸方向

X 軸方向

Y 軸方向

X direction

Y direction

Direction

Distance

G

20 ~ 40mm

X

± 10mm

Y

± 20mm

■ Long Distance Specification Head

* The total axis misalignment 

of XY for long distance 

specifications is up to 20mm.

■ Standard Specification Head

■ Standard Specification Head

Type code

A

B

C

D

RCS600-AH

170

45

300

46

RCS600-CH

・Mutual Interference between the heads

If you are installing in parallel head, to avoid the effects of mutual interference, please attach the 
head with an interval greater than or equal to the value shown in the table below always.

■ Long Distance Specification Head

Type code

E

F

G

H

RCS600-AH-L

190

40

290

40

RCS600-CH-L

(mm)

(mm)

Содержание RCS600

Страница 1: ...reless charging system RCS600 of B PLUS Please read the instruction manual before use and please use the products correctly Wireless charging system 600W specification Manual RCS600 for 12V 24V 48Vbat...

Страница 2: ...ion Caution Do not do the resolution and remodeling Failure to do so may result in fire electric shock or malfunction In addition there is a risk that can lead to serious injury When I perform the res...

Страница 3: ...your hands or metal objects between the coils during operation There and heat generated by induction heating the potential to catch fire Do not install in a place that may be exposed to high temperat...

Страница 4: ...oses other than battery charging we cannot guarantee it Specifications subject to change without notice If there is a point of notice about the contents of this document hope you ll give me your conta...

Страница 5: ...charging 21 About charge control 22 Other 24 9 About included product and optional products 25 10 Identifying and troubleshooting abnormalities 28 11 Consultation on how to use and repair 30 Shown in...

Страница 6: ...8V type Charging method See page 22 for the detailed charge control CC CV charge control 1 Charging voltage Max 15V Charging current Max 34A CP CV or CC CV charge control 1 Charging voltage Max 35V Ch...

Страница 7: ...age is other than 32 0 5 to 61 0 5V Over current protection When charging current reaches a certain level or more it stops Over voltage protection When charging voltage reaches a certain level or more...

Страница 8: ...3 Operating temperature 0 50 Storage temperature 10 50 Operating humidity 35 90 RH or less However no condensation Isolation 50M Ohm Dielectric strength AC1500V 1 minute Shock rating 10 G in the X Y a...

Страница 9: ...r details Operating temperature 0 50 Storage temperature 10 50 Operating humidity 35 90 RH or less However no condensation Isolation 50M Ohm Dielectric strength 2000 VAC 1min Shock rating 10 G in the...

Страница 10: ...n 50M Ohm Dielectric strength AC1500V 1min Shock rating 10 G in the X Y and Z directions 11 ms Vibration rating 19 6 m sec 2 10 to 55 Hz 20 times in X and Y directions protection class IP40 Indoor ins...

Страница 11: ...lacement of the XY axes can be up to 20mm See page 13 for details Operating temperature 0 50 Storage temperature 10 50 Operating humidity 35 90 RH or less However no condensation Isolation 50M Ohm Die...

Страница 12: ...ing metal keep minimum spacing Also please remove metal chips and cutting pieces on the transmission surface of the head part Metal piec es may generate heat which may result in damage to equipment or...

Страница 13: ...nce G 0 20mm X 10mm Y 15mm X Y X Y X direction Y direction Direction Distance G 20 40mm X 10mm Y 20mm Long Distance Specification Head The total axis misalignment of XY for long distance specification...

Страница 14: ...manual is available No T320403 5 Maintenance Maintenance The cooling fan and power switch may require maintenance depending on the operating environment and frequency of use If you notice any abnormal...

Страница 15: ...n Present Error Indicates abnormality Light in Red Present Error code Display abnormal contents by combination E1 E3 Light in Red Present Power supply unit display For details on how to identify and d...

Страница 16: ...ase set the grounding resistance to 100 or less Power switch Turn main power ON OFF Exhaust port In order to exhaust internal heat by the fan consider it so that exhaust heat can dissipate to the outs...

Страница 17: ...y are indicated by LED lighting combinations of E1 to E3 16 20 17 20 18 20 Output I O connector function The operation status of the charging unit is output to the outside simultaneously with the LED...

Страница 18: ...through the cable without wrapping it once it will take 1 turn 7 Connection diagram Standard Specification Head 2T 2 2 Charging cable is not included A cable of 5 5 sq or more is recommended Dsub25P...

Страница 19: ...urns For the power cable attach 1 piece of additional ferrite core clamp included with the active head within 300 mm in addition to the one already installed at the time of shipment Refer to the figur...

Страница 20: ...clamp to the unit side connector for power supply Power Supply unit RCS600 AC connector for communication RFC H13 Ferrite clamp Within 2T 100mm Active Head RCS600 AH 2T 2 turns Refer to the photo on...

Страница 21: ...or CP CV charge control method See 24V type for Recharge ON timer function Charging parameter setting When setting the battery charging current to 10A or more change the values of output overcurrent...

Страница 22: ...d but when the charge amount increases and the battery voltage reaches the set charge voltage value it shifts to constant voltage charge control CV Squeeze the charging current so that it does not exc...

Страница 23: ...etting value is high the characteristic graph shows that the current decreases as the voltage increases RCS600 CA24 SCIB SIP24 23 50 11Ah Charge Characteristics After Discharge Constant power 600W Max...

Страница 24: ...control and state control of the battery Other Using RCS600 B CA48 CYCLON G G 16EP four12V batteries connected in series 50 8A Charge characteristics after discharge Constant power 600W Max 12A CV Vol...

Страница 25: ...e unit to the air inlet section See P 14 A separate instruction manual is available Document No T320403 Reference example Both sides need to be attachd B PLUS K K CODE 1 1 25 3 5 2 F0 3sq 1515 30 6 4...

Страница 26: ...Pale Blue 1 Brown 4 Red 5 Orange 6 Yellow 7 Green 8 Purple Disconnected 2 3 9 10 11 12 13 15 19 21 22 23 24 25 Connector pin number Active Head Passive Head Various extension cables 600W 600W RCS600...

Страница 27: ...1 5m RCS600AH PWR 015 2 5m RCS600AH PWR 025 Extension cable for passive head Signal Robot cable 1 5m RCS600CH SIR 015 The maximum length of the cable should not exceed 5 0m when using the optional cab...

Страница 28: ...to 16 0 5 V or less 24V Detect battery voltage 16 0 5 to 31 0 5 V or less 48V Detect battery voltage 32 0 5 to 61 0 5 V or less Use of different types of bat teries such as rated voltage difference R...

Страница 29: ...or it may take longer to fully charge Review the cable length and cable con ductor diameter Only power LED is lit The fuse may be blown or the internal circuit may be broken Please contact to our sale...

Страница 30: ...eries in series fully charge each battery to the same voltage before installing the equipment When using two batteries in series fully charge each one to the same voltage before installing the equipme...

Отзывы: