Position
Value
Type
500 mA
RAPIDO
5 A
F1
F2
RAPIDO
Description
Accessories power supply input protection
Board protection on 230 Vac power supply input
PROTECTION FUSES
DIP
Function
Description
Status
DIP 1
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ININFL.
ON
OFF
ON
ON
OFF
ON
ON
OFF
DIP 2
DIP 3
DIP 2
DIP 3
DIP 2
DIP 3
DIP 5
DIP 8
DIP 5
DIP 8
DIP 5
DIP 8
DIP 2
DIP 3
DIP 4
TIME
LEARNING
STEP – STEP
STOP STOP
STEP - STEP
NOT ENABLED
RADIO INPUT
MANAGEMENT
CONDOMINIUM
EXTERNAL
COMMANDS
MANAGEMENT
Enables the time learning procedure
Normal functioning
I Start pulse: OPENS
II Start pulse: STOPS (it will not close automatically)
III Start pulse: CLOSES
IV Start pulse: STOPS
I Start pulse: OPENS
II Start pulse: CLOSES
III Start pulse: OPENS
Channel 1 transmitter: opens
Channel 3 transmitter: closes
Channel 2 and 4 transmitter: stops the motion
The control unit recognizes only one radio input set with the DIP 6 and 7
The control unit recognizes only one radio input set with the DIP 6 and 7 but:
the continuous pressure for 3 s on the channel 1 of the transmitter manages the
opening of ALL the control units on which the transmitter is memorized;
the continuous pressure for 3 s on the channel 3 of the transmitter manages the
closing of ALL the control units on which the transmitter is memorized.
During opening, it does not receive other START commands after the first one, in
pause other START commands reload the pause time.
I Start pulse: OPENS
Next Start pulses: uninfluential
Pause from FCA or end of opening time
Start pulse during pause: reloads pause time (if automatic closing is enabled)
or CLOSES (if automatic closing is disabled)
Start pulse during closing: OPENS
The keys GENERAL_OPEN and GENERAL_CLOSE work with DEAD MAN logic.
Keeping the key pressed, the motion stops for one second and then the manoeuvre
starts.
The key GENERAL_OPEN manages only opening. Keeping the key pressed, the
motion stops for one second and then the manoeuvre starts.
The key GENERAL_CLOSE manages only the closing. Keeping the key pressed, the
motion stops for one second, then the manoeuvre starts.
FUNCTIONS PROGRAMMING ( DIP SWITCH DIP1)
The settings are memorized during the pause phase (door closed).
SR100
11