![B&G Vulcan R Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/bandg/vulcan-r/vulcan-r_installation-manual_460138023.webp)
Power connections
5" unit power connection
The unit is powered by 12 V DC. It is protected against reverse
polarity, under voltage, and over voltage (for a limited duration).
The plug of the supplied power cable has two discrete cables
exiting from it. The thickest of the two cables provides the
following:
•
Power into the system (Red and Black wires).
•
Controlling power state of the unit (Yellow wire).
1
6
+ _
2
3
5
4
1
Power cable
2
12 V DC positive wire (red) shown with fuse holder fitted
3
12 V DC negative wire (black)
4
Power control wire (yellow)
5
Vessel’s 12 V DC supply
6
NMEA 2000 cable and connector
Connect Red to (+) DC using a 3 amp fuse.
Connect Black to (-) DC.
The unit can be powered on and off using the power button on the
front of the case.
Wiring
| Vulcan R Series Installation Manual
23