27
PanelMax
installation instructions
F - Setting Limits via Transmitter
S T E P O N E
The SPEED setting on the opener CAN NOT be
adjusted when setting limits via the transmitter.
Follow section 12.1 to set limits and adjust speed.
S T E P T W O
Switch power on
tip
S E T T I N G L I M I T S V I A T R A N S M I T T E R
+
BLUE LED will flash
& gear LED lit
Remove controls cover
till remote
LED lit
Press
repeatedly
S T E P T H R E E
HOLD
Opener
flashes &
beeps
HOLD for 3 sec
HOLD for 3 sec
RELEASE
Release both
buttons
Then refit
controls cover
S T E P O N E
C L O S E L I M I T P O S I T I O N
S T E P T W O
HOLD
When door near
close, single
presses inch door
CLOSE limit should be
when rubber strip touches
the ground
to Close
S T E P T H R E E
W A R N I N G ! In setting the close limit position,
do not force the door into the floor with
excessive force, as this can interfere with the
ease of operation of the manual release
mechanism.
If door overshoots
Press to Open
Press to Close
position
Press to set
Button 4 is factory coded
to CLOSE function.
Button 2 is factory
coded to SET function
S T E P O N E
O P E N L I M I T P O S I T I O N
HOLD
to Open
Button 1 is factory coded
to OPEN function.
When door near
open, single
presses inch door
OPEN limit should be the
height of the garage
opening
S T E P T W O
W A R N I N G ! The door will automatically close.
open and close again after the next step.
Ensure that nothing is in the door’s path.
S T E P T H R E E
If door overshoots
Press to Close
Press to Open
position
Press to set