background image

25

PanelMax

 installation instructions

B - Adjustment Mode Instructions

Parameter

Value options = Indicated by brightness  

of main light

1

2

3

4

5

6

MARGIN

x1

1.0A

1.2A

1.4A

1.6A

2.0A

-

PE AUTO-CLOSE

x2

OFF

15sec

30sec

60sec

90sec

-

AUTO-CLOSE

x3

OFF

15sec

30sec

60sec

90sec

120sec

LIGHT TIMER

x4

30sec

60sec

90sec

120sec

180sec

240sec

AUX OUTPUT

x5

Mimic 

light

1sec

30sec

60sec

120sec

180sec

240sec

300sec

600sec

toggle

When parameter edit 

mode is active, if any 

button other than MODE is 

pressed, then when MODE 

is pressed again, operating 

mode will be selected 

instead of the NETWORK 

adjustment mode. 

tip

AUX OUPUT
•  Configures how the AUX Output operates. If 

configured for Mimic light mode then the AUX 

output will activate whenever the main light 

output is on. 

•  All other settings require either a remote control 

code set to the AUX function or the Phone App to 

be used to activate the output. 

•  The time settings option indicates how long 

the output will remain on when triggered. If the 

output is already on, then a 2nd trigger will turn 

the output off. 

•  The toggle On/Off setting does not use a timer 

and the output simply changes state on each 

trigger..

S T E P   O N E

S T E P   T H R E E

Remove controls cover

till gear LED 

starts flashing

Press

repeatedly

A D J U S T M E N T   M O D E   I N S T R U C T I O N S

S T E P   T W O

S T E P   F O U R

If no beep is heard, max 

or min setting is reached.

Press to move 

through options as 

per table below

OR

Observe the number 

of flashes to indicate 

the parameter.

Press

to enter 

parameter

the remote LED is 

lit when editing 

active

OR

Use either button to 

scroll through

Pressing the MODE button when a parameter is 

being adjusted will load the default value.

tip

Press to save 

OR

Press to leave 

unchanged

Press to 

exit

Operating MODE is 

entered after 5 secs, 

unless a new 

adjustment is started 

or saved.

S T E P   F I V E

S T E P   O N E

S T E P   T H R E E

Remove controls cover

till gear LED 

starts flashing

Press

repeatedly

A D J U S T M E N T   M O D E   I N S T R U C T I O N S

S T E P   T W O

S T E P   F O U R

If no beep is heard, max 

or min setting is reached.

Press to move 

through options as 

per table below

OR

Observe the number 

of flashes to indicate 

the parameter.

Press

to enter 

parameter

the remote LED is 

lit when editing 

active

OR

Use either button to 

scroll through

Pressing the MODE button when a parameter is 

being adjusted will load the default value.

tip

Press to save 

OR

Press to leave 

unchanged

Press to 

exit

Operating MODE is 

entered after 5 secs, 

unless a new 

adjustment is started 

or saved.

S T E P   F I V E

DEFAULT parameter 

(underlined)

tip

LIGHT TIMER
•  Adjusts the time the main light will remain on after 

the door is operated or a remote control code set 

to the Light remote control function is used.

Содержание PanelMax SDO-8V3

Страница 1: ...oor Opener installation instructions PanelMax These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161060_04 RELEASED 11...

Страница 2: ...evel or other access level except for horizontally moving pedestrian doors ensure that entrapment due to the opening movement of the driven part is avoided 2 Before you Begin 5 3 Tools Required 5 4 Ki...

Страница 3: ...ues when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without th...

Страница 4: ...e BATTERY WARNING This product contains a lithium button coin cell battery in the transmitters If a new or used lithium button coin cell battery is swallowed or enters the body it can cause severe int...

Страница 5: ...rce required to move the door should not exceed 20kg d Lift the door to about halfway When released the door should stay in place 2 1 Examine the conditions in the garage a Look at the ceiling i Is it...

Страница 6: ...rotected from weather b REQUIRES properly earthed 3 pin single phase power on the ceiling within an arms length of the opener c Requires a MINIMUM HEADROOM of 57mm between the highest point of the doo...

Страница 7: ...failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profressional for installation DIY c Us...

Страница 8: ...perforate L shape metal drop down strips Not supplied Straighten the antenna on the opener by pulling straight down to ensure optimal reception tip 9 Mounting Brackets and Arms 9 1 Mounting the Door...

Страница 9: ...beam 100mm above the ground level as per AS NZS 60335 2 95 2020 This can be achieved by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as c...

Страница 10: ...700N Door travel speed mm sec 180mm Rated load 400N Maximum lifting under spring tension 200N 20kg Receiver type Multi frequency UHF FM Receiver code storage capacity 64 X 4 button Transmitters Transm...

Страница 11: ...R SPEED MODE x 3 3 x FAST Default x 2 2 x MEDIUM x 1 1 x SLOW RELEASE When at desired speed S T E P F I V E When door near close single presses inch door Press to close door HOLD CLOSE limit should be...

Страница 12: ...ress repeatedly R E P R O F I L I N G T H E D O O R HOLD for 2 secs Door will open and close Re profiling is a simple way of re learning the travel characteristics of a previously setup Limit Switch t...

Страница 13: ...the door b Press the transmitter button again to open the door c When the door reaches approximately half way firmly grab the door s bottom rail the door should stop If the door does not reverse read...

Страница 14: ...an obstruction or stalling ii Safety Beam triggered auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is triggered ie c...

Страница 15: ...xample Secure Auto Lock Wireless PE Beams Smart Hub If an Auto lock and Wireless PE Beams are both installed ensure that the channels on the base stations on each device are different The channel on t...

Страница 16: ...n through the coding hole S T E P T H R E E Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Take new remote RELEASE S T E P F I V E Press to test Opener stops flashing beeping S T E P F I V...

Страница 17: ...ontrols cover till remote LED lit Press repeatedly I N S T A L L I N G W A L L R E M O T E C O N T R O L S T E P T W O HOLD Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Release both butt...

Страница 18: ...N G A G E T H E O P E N E R 2 0 M A N U A L D O O R O P E R AT I O N C A U T I O N W h e n t h e o p e n e r i s m a n u a l l y d i s e n g a g e d t h e d o o r i s n o l o n g e r l o c k e d T o...

Страница 19: ...OW Green Opens the door 5 UP ARROW LED Green Illuminates when the door is open and flashes when the door is open with the auto close timer running obstructed on opening or stopped 6 MODE Yellow Enable...

Страница 20: ...itions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the bat...

Страница 21: ...ues and remedies Flashes FAULT x 2 or x 3 Failed while profiling door after setting limits Can be caused by any event which cause door to stop For example P E beam being blocked on closing hit an obst...

Страница 22: ...r mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure the door ope...

Страница 23: ...e steps for protecting the environment DO NOT throw the batteries in municipal waste This symbol of the crossed out wheeled bin indicates that the battery should not be placed in the municipal waste C...

Страница 24: ...CLOSED LEDS solid Open rapid flashing Open with Autoclose timer running flashing Opening Obstructed on Open solid Closed flashing Closing Obstructed on Close flashing flashing Stopped solid solid Part...

Страница 25: ...O D E I N S T R U C T I O N S S T E P T W O S T E P F O U R If no beep is heard max or min setting is reached Press to move through options as per table below OR Observe the number of flashes to indi...

Страница 26: ...Then refit controls cover Press to exit Remove controls cover till gear LED flashing Press repeatedly When activated PET mode drives the door to a preset position from the close position therefore al...

Страница 27: ...imit should be when rubber strip touches the ground to Close S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as this can i...

Страница 28: ...Australia Pty Ltd 28 your representative is PanelMax installation instructions G Setting up Tilt Door Prior to limit set up the opener can be set to J Type Tilt Profile This process allows the opener...

Отзывы: