background image

13

PanelMax

 installation instructions

13. Safety Testing

CAUTION: Take care when completing a 

safety test. Failure to follow this warning 

can result in serious personal injury 

and/or property damage.

WARNING! If the door is closing and is unable to  

re-open when obstructed, discontinue use Do not 

use a door with faulty obstruction sensing.  

Wood 40mm high

WARNING! If the door fails these tests, 

put the opener into manual mode, 

only operate the door by hand and 

call for service.

WARNING! Safety beams must be 

installed if the closing force at the 

bottom edge of the door exceeds 

400N (40kg).

13.1 Test the Close Cycle

a. Press the OPEN button 

 or transmitter button to open the 

door (If the door starts closing, press the transmitter button to 

stop the door, then press transmitter again to open).

b. Place a piece of timber approximately 40mm high on the 

floor directly under the door.

c. Press the transmitter button to close door.  

d. The door should strike the object and re-open.

e. Remove the timber .

13.2 Testing the Open Cycle

a. Press the CLOSE button 

 or transmitter button to close the 

door.

b. Press the transmitter button again to open the door. 

c. When the door reaches approximately half way, firmly grab 

the door’s bottom rail -  the door should stop.

If the door does not reverse readily when closing, or stop when 

opening, put the door into manual by pulling down on the 

manual release string to diesengage the motor and contact 

13 62 63 for support.

13.3 Test the Manual Door Operation

A poorly maintained door could cause fatal / serious injuries or 

damage to property:

a. Frequently examine the door, particularly the cables, springs 

and mountings for signs of wear, damage or imbalance.  

DO NOT USE

 if repair or adjustment is needed since a fault in 

the installation or an incorrectly balanced door may cause 

injury.

b. Fasterners: Check all screws, nuts and bolts to ensure they 

are secure. 

c. Spring Tension: It is natural for springs to lose tension. Should 

the door become hard to operate or completely inoperative, 

contact a door professional. 

d. Guide Tracks: Clean the internal sections of the guide tracks 

every 3 - 6 months with a cloth dampened with mineral turps 

or methylated spirits.

e. Periodically disengage the opener and manually operate 

the door. The door must be smooth to operate by hand. The 

force required on the bottom rail should not exceed 20kg.

Содержание PanelMax SDO-8V3

Страница 1: ...oor Opener installation instructions PanelMax These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161060_04 RELEASED 11...

Страница 2: ...evel or other access level except for horizontally moving pedestrian doors ensure that entrapment due to the opening movement of the driven part is avoided 2 Before you Begin 5 3 Tools Required 5 4 Ki...

Страница 3: ...ues when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without th...

Страница 4: ...e BATTERY WARNING This product contains a lithium button coin cell battery in the transmitters If a new or used lithium button coin cell battery is swallowed or enters the body it can cause severe int...

Страница 5: ...rce required to move the door should not exceed 20kg d Lift the door to about halfway When released the door should stay in place 2 1 Examine the conditions in the garage a Look at the ceiling i Is it...

Страница 6: ...rotected from weather b REQUIRES properly earthed 3 pin single phase power on the ceiling within an arms length of the opener c Requires a MINIMUM HEADROOM of 57mm between the highest point of the doo...

Страница 7: ...failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profressional for installation DIY c Us...

Страница 8: ...perforate L shape metal drop down strips Not supplied Straighten the antenna on the opener by pulling straight down to ensure optimal reception tip 9 Mounting Brackets and Arms 9 1 Mounting the Door...

Страница 9: ...beam 100mm above the ground level as per AS NZS 60335 2 95 2020 This can be achieved by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as c...

Страница 10: ...700N Door travel speed mm sec 180mm Rated load 400N Maximum lifting under spring tension 200N 20kg Receiver type Multi frequency UHF FM Receiver code storage capacity 64 X 4 button Transmitters Transm...

Страница 11: ...R SPEED MODE x 3 3 x FAST Default x 2 2 x MEDIUM x 1 1 x SLOW RELEASE When at desired speed S T E P F I V E When door near close single presses inch door Press to close door HOLD CLOSE limit should be...

Страница 12: ...ress repeatedly R E P R O F I L I N G T H E D O O R HOLD for 2 secs Door will open and close Re profiling is a simple way of re learning the travel characteristics of a previously setup Limit Switch t...

Страница 13: ...the door b Press the transmitter button again to open the door c When the door reaches approximately half way firmly grab the door s bottom rail the door should stop If the door does not reverse read...

Страница 14: ...an obstruction or stalling ii Safety Beam triggered auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is triggered ie c...

Страница 15: ...xample Secure Auto Lock Wireless PE Beams Smart Hub If an Auto lock and Wireless PE Beams are both installed ensure that the channels on the base stations on each device are different The channel on t...

Страница 16: ...n through the coding hole S T E P T H R E E Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Take new remote RELEASE S T E P F I V E Press to test Opener stops flashing beeping S T E P F I V...

Страница 17: ...ontrols cover till remote LED lit Press repeatedly I N S T A L L I N G W A L L R E M O T E C O N T R O L S T E P T W O HOLD Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Release both butt...

Страница 18: ...N G A G E T H E O P E N E R 2 0 M A N U A L D O O R O P E R AT I O N C A U T I O N W h e n t h e o p e n e r i s m a n u a l l y d i s e n g a g e d t h e d o o r i s n o l o n g e r l o c k e d T o...

Страница 19: ...OW Green Opens the door 5 UP ARROW LED Green Illuminates when the door is open and flashes when the door is open with the auto close timer running obstructed on opening or stopped 6 MODE Yellow Enable...

Страница 20: ...itions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the bat...

Страница 21: ...ues and remedies Flashes FAULT x 2 or x 3 Failed while profiling door after setting limits Can be caused by any event which cause door to stop For example P E beam being blocked on closing hit an obst...

Страница 22: ...r mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure the door ope...

Страница 23: ...e steps for protecting the environment DO NOT throw the batteries in municipal waste This symbol of the crossed out wheeled bin indicates that the battery should not be placed in the municipal waste C...

Страница 24: ...CLOSED LEDS solid Open rapid flashing Open with Autoclose timer running flashing Opening Obstructed on Open solid Closed flashing Closing Obstructed on Close flashing flashing Stopped solid solid Part...

Страница 25: ...O D E I N S T R U C T I O N S S T E P T W O S T E P F O U R If no beep is heard max or min setting is reached Press to move through options as per table below OR Observe the number of flashes to indi...

Страница 26: ...Then refit controls cover Press to exit Remove controls cover till gear LED flashing Press repeatedly When activated PET mode drives the door to a preset position from the close position therefore al...

Страница 27: ...imit should be when rubber strip touches the ground to Close S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as this can i...

Страница 28: ...Australia Pty Ltd 28 your representative is PanelMax installation instructions G Setting up Tilt Door Prior to limit set up the opener can be set to J Type Tilt Profile This process allows the opener...

Отзывы: