manualshive.com logo in svg
background image

SETTING SAFETY OBSTRUCTION FORCE

13

7. SETTING OPEN AND CLOSE SAFETY

OBSTRUCTION FORCE

The  Safety  Obstruction  Force  is  calculated  automatically  and

set in memory on the Easylifter. This applies to both the Open

Force and Close Force.

Warning: When step 7.1 is initiated the garage door will do a

full open and close cycle automatically. Please keep doorway

clear to avoid any personal injury or damage to property. 

7.1 TO INITIALISE OBSTRUCTION FORCE

1. Press and hold the Close button (Fig. 20) to move the door

to the fully closed position. Check that the red LED is steady

ON, to confirm the door is set on the closed limit position 

2. Press the Reset button (Fig. 20) for two seconds, the door

should  start  opening.  When  the  door  reaches  the  fully  open

position it will pause momentarily then start to close. The door

has  to  do  a  complete  open  and  close  cycle  without

interruptions  for  the  safety  obstruction  parameters  to  be

calculated and set automatically.

A default  safety  force  margin  is  preset  in  the  factory.  Under 

normal operating conditions this default margin should not be

changed. If you are not satisfied with this setting you can adjust

it as per the procedure below.

IMPORTANT NOTE:

Whenever  the  limit  switches  or  cams  are  adjusted  the  safety

obstruction  force  has  to  be  re-initialised  because  the  door’s

travel  distance  may  have  changed.  To  re-initialise  the  door

follow STEP 7.1 above.

7.2 TO INCREASE FORCE PRESSURE

1. Press and hold the Force Margin Set button (Fig. 20).

2. While  holding  Force  Margin  Set  press  the  green  Open

button. The green LED will illuminate each time the green open

button  is  pressed  to  indicate  that  the  force  pressure  is  being

increased. If the green LED flashes continuously when the open

button  is  pressed,  this  indicates  that  the  maximum  force 

pressure setting has been reached.

7.3 TO DECREASE FORCE PRESSURE

1.  Press and hold the Force Margin Set button (Fig. 20).

2. While holding down button press the red Close button. The

red LED will illuminate each time the Close button is pressed,

to indicate that  the force pressure is being reduced. If the red

LED flashes continuously when the close button is pressed, this

indicates  that  the  minimum  force  pressure  setting  has  been

reached.

7.4 TO RECALL FACTORY SET FORCE 

1. While holding the Force Margin Set button press the RESET

button for two seconds.

2. Release  both  buttons.  The  default  setting  should  now 

be  recalled

FIG. 21

FIG. 20

WOOD (40mm High)

7.4 SAFETY OBSTRUCTION TEST
TESTING CLOSE CYCLE
1. Open the door by pressing the Yellow O/S/C button (Fig. 20).
2. Place a length of timber 40mm high on the floor directly under
the door (Fig. 21).
3. Press the Yellow O/S/C button to close door. The door should
strike the object and start to re-open.

TESTING OPEN CYCLE
1. Close the door by pressing  the Yellow  O/S/C button. (Fig. 20).
2. Press  again  to  open  the  door.  When  the  door  opens  half  way
grab the bottom rail  of  the  door  firmly,  the  door  should  stop.  

If  the  door  does  not  reverse  readily  when  closing,  or  stop  when
opening, the force may be excessive and need adjusting, refer to
STEP 7.1, 7.2, 7.3 and 7.4.

IMPORTANT WARNING: If the door is closing and is unable to
re-open when obstructed discontinue use. Do not use a door with
faulty obstruction sensing. Repair fault and re-test before using.

Содержание Easylifter

Страница 1: ...ns to follow all instructions Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please...

Страница 2: ......

Страница 3: ...vehicles within the doorway Install the wall switch or wall mounted transmitter in a LOCATION POSITION where it is out of reach of children and the garage door is visible The door opener is not intend...

Страница 4: ...e indicator When the Overload LED and the beeper sounds at the start of a door cycle this means that the opener and or garage door requires service CAS COLOUR ASSISTED SETTINGS To make the installatio...

Страница 5: ...n is used to set the open limit stop position 11 OPEN Drive button Green is used during installation to help set the open limit stop position Pressing this button will move the door in the open direct...

Страница 6: ...ED 5 AUTO CLOSE BUTTON WHITE 6 RESET BUTTON 7 O S C BUTTON YELLOW 8 CLOSE LIMIT ADJUST SCREW RED 9 OPEN LIMIT ADJUST SCREW GREEN 10 OPEN LIMIT CAM GREEN 11 OPEN DRIVE BUTTON GREEN 12 OPEN LIMIT RED 13...

Страница 7: ...NSMITTER 1 ALKALINE BATTERY A23 12V 1 WEIGHT BARS NOT INCLUDED IN SOME MODELS 2 SCREW M5x40mm NOT INCLUDED IN SOME MODELS 4 HEX NUT M5 NOT INCLUDED IN SOME MODELS 4 SPRING WASHER I D 5 NOT INCLUDED IN...

Страница 8: ...either removed or disabled and remove unnecessary accessories 2 FIXING OF DOOR WEIGHT BARS Move the door manually to the mid open position Place the weight bars equally apart on the bottom rail of th...

Страница 9: ...FOLLOW THIS WARNING 4 Check that Steps 2 and 3 was completed Carefully loosen and remove the right hand door shaft U bolt 5 Make sure that the door supporting prop is secure While the door is support...

Страница 10: ...the cam clicks the open limit switch 3 Move the door down by hand to the desired closed position 4 Rotate the red limit cam by hand in a clockwise direction Fig 16 until the cam clicks the close limit...

Страница 11: ...y 10 mm of door travel NOTE If the door has not reached the desired limit position by more then 30mm then it is recommended that the red limits cam be adjusted again before the red fine adjustment scr...

Страница 12: ...more then 30mm it is recommended that the green limit cam be adjusted again before the green fine adjustment screw is turned CLOSE LIMIT ADJUSTMENT Press and hold the red Close button Fig 19 The door...

Страница 13: ...pen button The green LED will illuminate each time the green open button is pressed to indicate that the force pressure is being increased If the green LED flashes continuously when the open button is...

Страница 14: ...on the Easylifter opener The Door Code LED will illuminate to indicate that learn mode is activated If a valid code is not stored in 15 seconds the Easylifter opener will exit learn mode 2 SMART CODE...

Страница 15: ...itter without operating the door To code one of the remote control transmitter buttons to turn the courtesy light on and off 1 Press the Light Code button on the opener The Light Code LED will illumin...

Страница 16: ...timer will only start after the Photo Electric Beams P E path is broken and the auto close time has been set If the P E path is not broken the door will remain open until the path is broken If the doo...

Страница 17: ...heel OPENER MAXIMUM OPENING CLOSING RUN TIME 30 Secs RECEIVER TYPE UHF 433 92 MHz AM Receiver RECEIVER CODE STORAGE CAPACITY 21 x Transmitter Button Codes shared between door operate and courtesy ligh...

Страница 18: ...on in the doorway Increase force margin setting and or re initialise the door See S tep 8 on page 1 1 Remove obstruction Door operates from drive unit O S C button but not from transmitter See note Tr...

Страница 19: ...SPARE PARTS LIST 19...

Страница 20: ......

Страница 21: ...onths ii in installation for a period of twelve 12 months from the date of installation where the Opener has been installed by B D or its Authorised Distributor 4 The warranties provided in clause 3 i...

Страница 22: ...lectronic interference ix Water damage including effects from rust and corrosion x Use with doors locked 11 The warranty contained in Clause 3 does not cover batteries or globes and B D shall not be l...

Страница 23: ......

Страница 24: ...4747 WA Office 96 Mulgul Drive Malaga 6090 Ph 08 9247 8777 NZ Office 70 Allens Road East Tamaki Auckland Ph 09 273 8600 www bnd co nz B D Doors is a Division of B D Australia Pty Limited ABN 25 010 47...

Отзывы: