5
OPERATING CONTROLS
1. LIGHT CODE button (White) is
used for storing or erasing the
transmitter button (code) you wish to
use to turn the opener’s courtesy light
on and off.
2. DOOR CODE button (Blue) is
used for storing or erasing the
transmitter button (code) you wish to
use to command the door to open, stop
or close.
3. CLOSE DRIVE button (Red) is
used during installation to help set the
close limit stop position. Pressing this
button will move the door in the close
direction. Movement stops when the
button is released.
NOTE: The close safety obstruction
detection is disabled when the Close
Drive button is used to move the door.
4. CLOSE LIMIT LED (Red) the
LED is very helpful during installation,
it illuminates and flashes while the door
is closing and remains steady on when
the close limit is reached.
5. AUTO CLOSE TIME button
(White) is used to adjust the auto close
time. While holding Auto Close and
pressing the Open button the time delay
is increased (each press will increase
the time by 5 seconds). Pressing the
Close button will decrease the time
delay.
6. RESET button is used to initialise
and set the door/opener operating
parameters, including cycle times and
obstruction force settings.
7. O/S/C button (Yellow) is used
during installation to test the Open, Stop
and Close cycles for the Opener. The
opener has to be initialised by the Reset
button before the O/S/C button becomes
operable.
8. CLOSE LIMIT ADJUST
SCREW (Red) is used to fine adjust the
close limit stop position.
9. OPEN LIMIT ADJUST SCREW
(Green) is used to fine adjust the open
limit stop position.
10. OPEN LIMIT CAM (Green) is
used to set the open limit stop position.
11. OPEN Drive button (Green) is
used during installation to help set the
open limit stop position. Pressing this
button will move the door in the open
direction. Movement stops when the
button is released.
NOTE: The open safety obstruction
detection is disabled when the Open
Drive button is used to move the door.
12. OPEN LIMIT LED (Green) the
LED is very helpful during installation.
It illuminates and flashes while the door
is opening and remains steady on when
the open limit is reached.
13. CLOSE LIMIT CAM (Red) is
used to set the close limit stop position.
14. FORCE MARGIN SET button
(White) is used to change the force
pressure when the door encounters an
obstruction. Pressing the Force Margin
Set button and Open or Close button
will increase or decrease the force.
Normally the force pressure is set
automatically. Force Margin Set is
only used if other environmental factors
(wind, etc.) effect the operation of the
Door/Opener.
15. P.E. INPUT is for connection of
Photo Electric Beams (optional extra)
for extra safety obstruction protection,
or compulsory when used with Auto
Close mode.
NOTE: P.E. SHUNT must not be
removed otherwise the opener will not
function correctly. Remove only when a
P.E. Beam is to be connected.
16. EXTERNAL RECEIVER
INPUT is the input where an external
receiver can be connected (optional
extra). It can supply 30mA @ 24 volts
DC maximum to power an external
receiver.
17. O/S/C INPUT is for connecting
the wired Wall Switch (optional extra) .
18. P. E. SHUNT The shunt has to be
removed when connecting a Photo
Electric Beam.
19. ENGAGE/DISENGAGEMENT
HANDLE when pulled down and
released will select manual mode on the
opener when there is a power failure.
Pulling down and releasing again will
switch the opener to automatic mode.