Configuration Instructions 

Many iMcV-Modules have user-configurable features (e.g., FiberAlert, LinkLoss, 
Auto Negotiation, etc.).  Refer to the chart for information on available features on 
each module.  Instructions for configuring both managed (via an SNMP-
compatible management application such as iView²) and unmanaged modules 
follow. 

Managed Modules 

To manage one or more iMcV-Modules, an SNMP agent must be present in the 
chassis. The iMediaChassis series, available in 3, 6 or 20 slots in both AC and 
DC, requires a separate SNMP Management Module.  To configure managed 
modules, install the module first, then configure it by using the management 
software.   

 

NOTE 

Management software overrides any hardware settings (e.g., jumper, switch, etc.), so 
make sure the module is configured through the software before beginning normal 
operation.  Until a module installed in a managed chassis is configured via the software, it 
will operate using the hardware configuration. 

Unmanaged Modules 

Before beginning installation of the iMcV-Modules, configure them for the desired 
features.  The chart below states the available features and settings for the 
iMcV-PIM and iMcV-LIM modules.  The board diagrams later in this manual show 
the jumper/switch locations on the modules.  

Since there are no user-

configurable features on the iMcV-S2MM/S2SM/M2MM modules, they can 
be installed straight from the box. 

After configuring the jumpers/switches for the desired settings, install the module 
and connect the appropriate cables (refer to the 

Installation

 section for more 

information). 

iMcV-Module Jumper/Switch Configuration Chart

 

Module 

Feature 

Jumper /Switch 

ON 

OFF 

Default 

IMcV-PIM 

TP/FO 

-10 Board 

Pulsing FiberAlert 

DIP Switch 1 

N/A 

N/A 

OFF 

iMcV-LIM 

TX/FX and 

TX/SSFX 

-30 Board 

FX LinkLoss 

JP2 

1-2 

2-3 

OFF 

TX LinkLoss 

JP3 

1-2 

2-3 

OFF 

Auto Negotiation 

DIP Switch 1 on S1 

see board 

see board 

ON 

FiberAlert* 

DIP Switch 2 on S1 

see board 

see board 

OFF 

 

Содержание iMcV-S2MM

Страница 1: ...iMcV Modules Operation Manual Above illustrations are representative some minor differences may be present in actual product...

Страница 2: ...tes dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada iMcV LIM iMcV PIM iMcV S2MM 155 iMcV M2MM 155 and iMcV S2SM 155 This equipment has been test...

Страница 3: ...ch have been adjusted modified or repaired by any party other than B B Electronics or iii any descriptions illustrations figures as to performance drawings and particulars of weights and dimensions co...

Страница 4: ...time Warranty iii About the iMcV Modules 1 Installation 1 LED Operation 1 Configuration Instructions 4 Installation Troubleshooting 9 Specifications 9 B B Electronics Technical Support 10 Fiber Optic...

Страница 5: ...Duplex data travels on different wavelengths 1310 nm and 1550 nm doubling the capacity of fiber Includes one RJ 45 connector and one SC fiber connector iMcV S2MM M2MM S2SM Protocol independent module...

Страница 6: ...nk is established on the twisted pair port located on RJ 45 ACT RJ 45 Glows amber when data is being passed on the twisted pair located on RJ 45 LNK Glows green when link is established on the fiber p...

Страница 7: ...data FA Glows green when FiberAlert is enabled FiberAlert is not available applicable on single strand versions of iMcV LIM LEDs on iMcV S2MM S2SM M2MM The LED functions on iMcV S2MM S2SM M2MM are as...

Страница 8: ...naged chassis is configured via the software it will operate using the hardware configuration Unmanaged Modules Before beginning installation of the iMcV Modules configure them for the desired feature...

Страница 9: ...5 About LinkLoss FiberAlert and Pulsing FiberAlert iMcV LIM TX FX and TX SSFX 30 Board iMcV PIM TP FO 10 Board...

Страница 10: ...at the device to which it is connected is up and sending pulses and that the copper or fiber cable coming from that device is intact The appropriate LNK link LED is lit to indicate this The B B Electr...

Страница 11: ...one side of the media conversion enabling it on both sides will keep both transmitters off indefinitely Pulsing FiberAlert Available on products 850 14940 through 850 14949 board revision 10 Pulsing...

Страница 12: ...connection Select a straight through connection by pressing the push button IN The button should be in the OUT position for a crossover connection If unsure of the type of connection set the push but...

Страница 13: ...t be disabled it is necessary to establish BOTH the twisted pair and fiber connections before the link LEDs will light To test a media converter by itself first make sure to have an appropriate fiber...

Страница 14: ...s Technical Support Tel 800 346 3119 in the U S and Canada Monday Friday 7 00am 7 00pm CST 353 91 792444 Europe Monday through Friday 8 00am 5 00pm GMT Fax 815 433 5109 U S and Canada 353 91 79244S5 E...

Страница 15: ...e between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product...

Страница 16: ...of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local...

Страница 17: ...91 792444 Fax 353 91 79244S5 Email techSupport bb elec com Website www bb elec com 2013 B B Electronics All rights reserved The information in this document is subject to change without notice B B Ele...

Отзывы: