DC Terminal Block Wiring Instructions
The IE-Giga-MiniMc can be powered via the DC terminal block. From a power
source, connect to any one positive and any one negative terminal on IE-Giga-
MiniMc.
Connected to Chassis
NOTE
When using stranded wire, the leads must be tinned and equivalent to a 16 AWG solid
conductor. The DC terminal block is protected against mis-wiring. If the unit is mis-
wired, positive power lead to the negative terminal and negative power lead to the
positive terminal, it will not function. When powering a unit with voltages near the
upper limit of the device’s specification (for example: 48 volts) take precautions to limit
the voltage at the units terminal block. When turning on high voltage DC circuits, initial
voltages may momentarily exceed the unit’s specification.