background image

1

 

About the IE-Giga-MiniMc 

The IE-Giga-MiniMc is a 10/100/1000 Auto Negotiating switching miniature 
media converter.  The fiber port always operates at 1000 Mbps Full Duplex; the 
copper port Auto Negotiates the connected device’s speed and duplex mode: 
10/100/1000 Mbps Half Duplex; or 10 /100/1000 Mbps Full Duplex (including 
Flow Control).  The IE-Giga-MiniMc supports jumbo packets up to 1632 bytes. 
The IE represents the unit’s use as an Industrial Ethernet device, which allows for 
extended temperature operation of -25°C to +85°C for DC power and -10°C to 
+50°C when using the included AC adapter. 
The IE-Giga-MiniMc converter offers plug-and-play operation, including the 
AutoCross feature which automatically selects between a crossover workstation 
and straight-through repeater hub connection depending on the connected 
device. 
The IE-Giga-MiniMc can use either the included B&B Electronics universal, 
external power adapter with 100 to 240 ±10% VAC input or can be wired directly 
to the 7-50 VDC terminal block (for extended temperature configuration).   There 
is an optional IE-PowerTray/18 in which up to 18 IE-Giga-MiniMcs can be 
installed. 

Содержание IE-Giga-MiniMc

Страница 1: ...IE Giga MiniMc Operation Manual...

Страница 2: ...depreciated value Products of other manufacturers sold by B B Electronics are not subject to any warranty or indemnity offered by B B Electronics but may be subject to the warranties of the other manu...

Страница 3: ...t defined About the IE Giga MiniMc 1 Installing the IE Giga MiniMc 2 Hardware Mounting Options 3 LED Operation 4 DC Power Supply Precautions 7 Specifications 8 B B Electronics Technical Support 9 Fibe...

Страница 4: ...allows for extended temperature operation of 25 C to 85 C for DC power and 10 C to 50 C when using the included AC adapter The IE Giga MiniMc converter offers plug and play operation including the Au...

Страница 5: ...f the IE Giga MiniMc support single strand fiber for operation Since single strand fiber products use optics that transmit and receive on two different wavelengths single strand fiber products must be...

Страница 6: ...B Electronics Distributor DIN Rail Clips The DIN Rail clips include screws to allow the installation onto a DIN Rail Install the screws into DIN Rail clips which should be mounted parallel or perpend...

Страница 7: ...ion Each IE Giga MiniMc converter includes two LEDs located on the RJ 45 connector LED functions are as follows FX TX LED functions are as follows above illustration is representative FX LNK ACT Glows...

Страница 8: ...AWG solid conductor The DC terminal block is protected against mis wiring If the unit is mis wired positive power lead to the negative terminal and negative power lead to the positive terminal it wil...

Страница 9: ...ading Power When installing multiple IE Giga MiniMc units on a DIN rail connect to one DC input source and then cascade from one DC block to the next until reaching the maximum electrical current avai...

Страница 10: ...rent source The 7 to 50 VDC source must be connected to a 7 to 50 VDC SELV source b The maximum terminal voltage is 50 VDC c Input wiring to terminal block must be routed and secured in such a manner...

Страница 11: ...o 240 10 VAC input 5 VDC output 2 A max Power Tray 18 Slot AC for Miniature Converters 125W 20A 5V Operating Temperature 13 F to 185 F 25 C to 85 C DC terminal block 14 F to 122 F 10 C to 50 C with IM...

Страница 12: ...s Technical Support Tel 800 346 3119 in the U S and Canada Monday Friday 7 00am 7 00pm CST 353 91 792444 Europe Monday through Friday 8 00am 5 00pm GMT Fax 815 433 5109 E Mail support bb elec com Web...

Страница 13: ...e problems in an installation 2 Dust caps are installed at B B Electronics to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber...

Страница 14: ...available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 Aft...

Страница 15: ...bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste I...

Страница 16: ...13...

Страница 17: ...3 91 792444 Fax 353 91 79244S5 Website www bb elec com 2013 B B Electronics All rights reserved The information in this document is subject to change without notice B B Electronics assumes no responsi...

Отзывы: