background image

Jumbo Jumpin’

 

Operators Manual

 

OPTION MENU 

Enter the options menu by pressing the “MENU” button located on the service panel inside 

the coin door. Advance through all options by pressing the “TEST” BUTTON. Increase 

displayed values with your foot by stepping on the right side of the mat. Reduce values 

using your foot by stepping on the left side of the mat.. 

The Game options include the following choices: 

1-

GAME VOLUME    This sets the volume for when a game is being played. Setting

it to “1" is the softest and “10" is the loudest. (Default setting is “

8

")

2-

ATTRACT VOLUME  This sets the volume of the music that plays during the

attract

 

mode. The range is “OFF”, “1” is the softest and “10" is the loudest. (Default

setting is “5")

3-

COINS TO START PLAY This option determines how many coins (pulses on the

COIN #1 input) will start a game. The range is “FREE PLAY”, 1 – 8.  The default

value is “1” and is typical for card reader systems. The Free play setting is for 

demonstration and trade shows. Free play games start when a player stands in the 

jump zone. Any tickets awarded during free play display as normal, but will not be 

dispensed. 

4-

COIN #2 VALUE  The second coin input can be set to a higher value in multiples of

coin #1. For example: Let;s say you want to accept quarters ($0.25) as coin  #1

and dollars ($1.00) as coin #2. Setting the COIN #2 VALUE to 4 tells the game that 

each pulse on the coin #2 input = 4 pulses on the coin #1 input.  This helps make 

the coin counter work properly using different coin values. The range is “OFF”, 1 – 

8. The default  setting is “1” (coin 2 = coin 1 value). The OFF setting can be

selected if the coin #2 input is not used.

5

5-

MONEY PROMPT This option tells the player the type of money accepted. The

options are: COINS, TOKENS, SWIPE CARD, INSERT CARD. The default setting

is SWIPE CARD. 

6-

WARM UP JUMP COUNT This sets the number of warm up jumps a player gets

before the game can end. The range is 1 – 9 (Default setting is “7”)

7-

STATION ID This option is used to identify more than one game. The range is 0 – 1

(default setting = 1). Zero identifies the master (or standalone) unit and one

identifies the slave unit. Up to two games can be connected together. 

IMPORTANT NOTE: no two games should be set to the same STATION ID. 

Содержание JUMBO JUMPIN'

Страница 1: ...JUMBO JUMPIN...

Страница 2: ...e reasonable protection against harmful interference when the equipment is operating in a commercial environment This equipment uses and can radiate radio frequency energy and if not installed and use...

Страница 3: ...ECIFICATIONS 1 2 0 INTRODUCTION 2 3 0 PRECAUTIONS 2 3 1 Installation 2 3 2 Handling 2 4 0 INSTALLATION 3 5 0 OPTION MENU 6 0 ERROR MESSAGES 7 0 DIAGNOSTICS 8 0 GAME PLAY 9 0 TROUBLESHOOTING 5 6 7 7 8...

Страница 4: ...0 Hz 5 Amps max 106 5 77 H x 111 W x 30 D 106 5 H x 73 W x 92 D 600 lbs Operators Manual Power cord Linking cable 1 Note Specifications subject to change without prior notice Modifications and or alte...

Страница 5: ...ot install in an area such that the game would present an obstacle in case of an emergency i e close to fire equipment or emergency exists 3 2 Handling 1 Before operating the game make sure that the m...

Страница 6: ...ews on both games a couple of turns Then feed one supplied linking cable Cat 5 RJ45 patch cord through the back panel holes and attach one end to each main logic port labeled LINK See Figure 2 Once co...

Страница 7: ...Figure 2 Figure 1...

Страница 8: ...ayer stands in the jump zone Any tickets awarded during free play display as normal but will not be dispensed 4 COIN 2 VALUE The second coin input can be set to a higher value in multiples of coin 1 F...

Страница 9: ...the number of minutes The range is 0 15 Default setting is 5 14 RES DEF RESET DEFAULTS When this is set to 1 and you exit the menu screen all of the game settings will be restored to their default val...

Страница 10: ...yed when an object stays in the Jump zone for over 1 minute Clear the object and the game will automatically return to normal operation If nothing is on the Jump zone make sure there is nothing under...

Страница 11: ...e is very low check for output shorts by removing load connectors one at a time ref overall wiring diagram in Appendix If loads are OK If the voltage is close try to trim the voltage using the adjustm...

Страница 12: ...NK JJ215 19301 00 PCB MAIN LOGIC JJ215 19302 00 PCB RGB CONTROLLER FLOOR MAT ASSEMBLY FLOOR MAT DECAL POWER SUPPLY 12VDC 350W MANUAL JUMPIN JACKPOT TICKET DISPENSER ENTROPY 2000 TICKET BIN W LOW TICKE...

Страница 13: ...10 Jumpin Jackpot Operators Manual APPENDIX B WIRING DIAGRAM...

Страница 14: ...xcept for any express warranty set forth in a written contract between Seller and Buyer which contract supersedes the terms herein this warranty is in lieu of all other warranties expressed or implied...

Страница 15: ......

Страница 16: ...e IL 60191 FAX 847 264 5613 Technical Assistance USA Main 847 264 5610 Fax 847 264 5611 Reorder Number JJ245 19385 00 NOVEMBER 2019 The specifications of this machine and the instructions in this Oper...

Отзывы: