background image

GRSM17 

Pneumatic 

Center Punch 

Tool

1.

For best results and proper functioning of the GRSM17 air tool, a filter / lubricator must be 
used on the air supply or in line within 30 feet of the air tool.  The warranty is voided if a  
filter / lubricator is not used.

2.

Before using air tool, check to see that the blade and backing plate on the CP head are fully 
tensioned.  Loose bolts can easily cause breakage of blade and backing plate.

3.

Clean gripper occasionally.  Particles and dirt on the gripper lever can cause it to slip off the 
clamp tail.  To remove gripper lever, loosen set screw in the head assembly from underneath 
the block and tap out pin.

4.

The BAND-IT GRSM17 Air Tool, although durable, does need periodic maintenance and 
repair. The frequency of significant repairs can be greatly reduced by simply following 
regular preventative maintenance such as maintaining tension on fasteners, proper 
lubrication and not “free cycling” the tool without tensioning clamps.

Preventative 
Maintenance

Frequency

Component

Check

Preventative Maintenance Schedule

Document# P47050 Rev. -

© Copyright 

BAND-IT-IDEX, Inc. 2008

All rights reserved

www.BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street Denver, CO 80216-3070 USA

P: 1-800-525-0758   F: 1-800-624-3925

8

Daily

Tool and tool head

Check for and tighten all fasteners.

Filter / Lubricator

Check for build-up of dirt, etc.  Check for contaminated or 
discolored lubricant.

Check for low lubricant. Refill with DTE 24 hydraulic oil.  Set 
drip rate to 1 drop each 10-25 cycles.

Every 2,000 clamps

Gripper

Check for build-up of dirt, etc., in teeth. Remove and clean. 
Replace as necessary with new gripper kit.

Every 5,000 clamps

Cutter Blade and
Backing Plate

Rotate both parts. If parts have been rotated once before, 
replace both as a kit.

Every 10,000 clamps

Tool Head

Return head to BAND-IT for service.

Every 6 Months

Cylinder

Check for build-up of dirt, contaminants on piston rod seals. 
Clean exterior with soap and warm water.

Tripper Plate

Check for build-up of dirt, contaminants, etc. Clean and 
apply lubricant.

Air Exhaust Mufflers

Check for build-up of dirt, contaminants, etc. Remove and 
clean with non-flammable degreaser.

Содержание GRSM17

Страница 1: ...Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 1 Table of Contents Page Information 2 Safety Guidelines and Warranty 3 Tool Overview and Installation 4 Air System Requirements 5 Setting Co...

Страница 2: ...er CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 2 harm Disconnect air supply prior to maintenance and disassembly of tool components Important advice and warning to user Read before applying cl...

Страница 3: ...eted and clamp tail is ready to be removed from the tool Upon completion of the tension lock and cut off cycle the operator should depress the heel Tool Overview and Installation Document P47050 Rev C...

Страница 4: ...blockage of air mufflers and a dirty environment Solvents Liquids such as solvents or cleaners should never be added to the air system through air lines Air System Requirements Oil drip rate Document...

Страница 5: ...X com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 5 pressure setting from below by increasing pressure Suggested settings...

Страница 6: ...rting an object that is soft and safe to hold into the end of the fitting for additional support may help Large diameter hose assemblies should be held securely with both hands Keep hands away from cl...

Страница 7: ...t lock Trouble Shooting Guide Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 8021...

Страница 8: ...ce Frequency Component Check Preventative Maintenance Schedule Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation...

Страница 9: ...to BAND IT Center Punch Head Information Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street De...

Страница 10: ...ent P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800...

Страница 11: ...r Pressure Gauges 2 Air Pressure Regulators 2 Air Connections for Supply to Cut off Cylinder End of Stroke Indicator Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT...

Страница 12: ...t BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Corporation 4799 Dahlia Street Denver CO 80216 3070 USA P 1 800 525 0758 F 1 800 624 3925 12 LENGTH INC...

Страница 13: ...rranty html Factory Services Additional Factory Support and Tool Service Document P47050 Rev Copyright BAND IT IDEX Inc 2008 All rights reserved www BAND IT IDEX com BAND IT IDEX Inc A Unit of IDEX Co...

Отзывы: