background image

14-51

Advanced Data Formatting

Keyboard Characters (continued)

Send (

Send )

Send +

Send *

Send ,

Send -

Send /

Send .

Содержание UNISCAN C6R

Страница 1: ......

Страница 2: ...Codice Code 0000010800 Revisione Release 1 00 settembre 2004...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...ner 1 3 Installing the Interface Cable 1 3 Connecting Power if required 1 4 Configuring Your Scanner 1 4 Connecting a Synapse Cable Interface 1 5 Removing the Interface Cable 1 5 Chapter 2 Scanning In...

Страница 8: ...er Volume 4 6 Power Mode 4 7 Laser On Time 4 8 Beep After Good Decode 4 9 Chapter 5 Keyboard Wedge Interface Introduction 5 1 Connecting a Keyboard Wedge Interface 5 2 Keyboard Wedge Default Parameter...

Страница 9: ...22 Nixdorf Beep LED Options 6 23 Ignore Unknown Characters 6 24 ASCII Character Set 6 25 Chapter 7 USB Interface Introduction 7 1 Connecting a USB Interface 7 2 USB Default Parameters 7 4 USB Host Par...

Страница 10: ...apter 10 Undecoded Scanner Emulation Interface Introduction 10 1 Connecting Using Undecoded Scanner Emulation 10 2 Undecoded Scanner Emulation Default Parameters 10 3 Undecoded Scanner Emulation Host...

Страница 11: ...o UPC A 12 20 EAN 8 JAN 8 Extend 12 21 UPC EAN Security Level 12 22 UCC Coupon Extended Code 12 24 Code 128 12 25 Enable Disable Code 128 12 25 Enable Disable UCC EAN 128 12 26 Code 39 12 27 Enable Di...

Страница 12: ...engths for MSI 12 64 MSI Check Digits 12 66 Transmit MSI Check Digit s 12 67 MSI Check Digit Algorithm 12 68 RSS Reduced Space Symbology 12 69 RSS 12 69 Convert RSS to UPC EAN 12 71 Redundancy Level 1...

Страница 13: ...rase 14 9 Quit Entering Rules 14 10 Disable Rule Set 14 11 Criteria 14 12 Code Types 14 12 Code Lengths 14 15 Message Containing A Specific Data String 14 20 Actions 14 24 Send Data 14 24 Setup Field...

Страница 14: ...mple Bar Codes Code 39 C 1 UPC EAN C 1 UPC A 100 C 1 EAN 13 100 C 2 Code 128 C 2 Interleaved 2 of 5 C 2 RSS 14 C 3 Appendix D Numeric Bar Codes 0 1 D 1 2 3 4 D 2 5 6 7 D 3 8 9 D 4 Cancel D 5 Glossary...

Страница 15: ...ecifications provides information on how to care for your scanner troubleshooting and technical specifications Chapter 4 User Preferences provides the programming bar codes necessary for selecting use...

Страница 16: ...or selecting these features for your scanner Chapter 13 Miscellaneous Scanner Options includes commonly used bar codes to customize how your data is transmitted to your host device Chapter 14 Advanced...

Страница 17: ...neral information to help the user get started with the scanner It includes basic set up and operation instructions Service Information If you have a problem with your equipment contact the Support Ce...

Страница 18: ...ur equipment for servicing If that is necessary you will be given specific directions Note A Bancolini Symbol is not responsible for any damages incurred during shipment if the approved shipping conta...

Страница 19: ...t laser scanner Whether used as a hand held scanner or in hands free mode in a stand the scanner ensures comfort and ease of use for extended periods of time Figure 1 1 Uniscan C6R Scanner This Unisca...

Страница 20: ...up by scanning bar codes USB connection to a host The scanner autodetects a USB host and defaults to the HID keyboard interface type Other USB interface types are selectable by scanning programming b...

Страница 21: ...secured 3 Connect the other end of the interface cable to the host see the specific host chapter for information on host connections Figure 1 2 Installing the Cable Note Different cables are required...

Страница 22: ...end of the power supply into an AC outlet Configuring Your Scanner Two methods are available to configure your scanner using the bar codes included in this manual or the 123Scan configuration program...

Страница 23: ...into the bottom of the scanner as described in Installing the Interface Cable on page 1 3 2 Align the S on the Synapse adapter cable with the S on the Synapse Smart Cable and plug the cable in 3 Conn...

Страница 24: ...1 6...

Страница 25: ...nning Introduction This chapter covers the techniques involved in scanning bar codes beeper and LED definitions and general instructions and tips about scanning Exit Window Trigger LED Beeper Figure 2...

Страница 26: ...igured Check option setting 5 low beeps Conversion or format error Lo hi lo beep ADF transmit error Hi hi hi lo beep RS 232 receive error Parameter Menu Scanning Short high beep Correct entry scanned...

Страница 27: ...up beep after scanning a USB Device Type Communication with the bus must be established before the scanner can operate at the highest power level This power up beep occurs more than once The USB bus...

Страница 28: ...lor LED display Table 2 2 defines LED colors that display during scanning Table 2 2 Standard LED Definitions LED Indication Off No power is applied to the scanner or the scanner is on and ready to sca...

Страница 29: ...ctions on programming your scanner Figure 2 2 Scanning in Hand Held Mode 1 Ensure all connections are secure Refer to the host chapter for your scanner 2 Aim the scanner at the bar code Press the trig...

Страница 30: ...ner from the bar code is known as specular reflection This specular reflection can make decoding difficult You can tilt the scanner up to 55 forward or back and achieve a successful decode Figure 2 3...

Страница 31: ...PC 17 0 23 0 20 mil in cm W i d t h o f F i e l d Minimum distance determined by symbol length and scan angle Depth of Field Note Typical performance at 73 F 23 C on high quality symbols in normal roo...

Страница 32: ...efore tightening the wingnut under the base ensure that the flat areas on the flexible neck fit securely in the grooves in the base Stand base Wingnut 1 Unscrew the wingnut from the bottom of the one...

Страница 33: ...2 Screw one 10 wood screw into each screw mount hole until the base of the stand is secure see Figure 2 6 Tape Mount 1 Peel the paper liner off one side of each piece of tape and place the sticky sur...

Страница 34: ...the stand it operates in its normal hand held mode Figure 2 7 Inserting and Using the Scanner in the Stand Intellistand operation 1 Ensure all cable connections are secure 2 Insert the scanner in the...

Страница 35: ...al descriptions pinouts Maintenance Cleaning the exit window is the only maintenance required A dirty window may affect scanning accuracy Do not allow any abrasive material to touch the window Remove...

Страница 36: ...loose Check for loose cable connections Laser comes on but symbol does not decode Scanner is not programmed for the correct bar code type Be sure the scanner is programmed to read the type of bar cod...

Страница 37: ...editing options Be sure proper host is selected See the host chapter for your scanner For RS 232 ensure the scanner s communication parameters match the host s settings For a USB HID keyboard or a key...

Страница 38: ...2 of 5 Discrete 2 of 5 Code 128 Code 93 MSI Code 11 UCC EAN RSS Code 32 Coupon Code Bookland EAN 1ATA and RSS Beeper Operation User selectable Enable Disable Beeper Volume User selectable three level...

Страница 39: ...rea discharge 8 kV contact discharge Minimum Element Width 5 mil 0 127 mm Interfaces Supported Decoded RS 232 Keyboard Wedge Wand Emulation Undecoded Scanner Emulation IBM 468X 469X USB Synapse Electr...

Страница 40: ...3 6 Scanner Signal Descriptions Figure 3 1 Scanner Cable Pinouts PIN 10 Bottom of scanner PIN 1 Interface cable modular connector Cable interface port...

Страница 41: ...served Reserved Reserved Jump to Pin 6 2 Power Power Power Power Power Power 3 Ground Ground Ground Ground Ground Ground 4 IBM_A Reserved TxD KeyClock DBP Reserved 5 Reserved Reserved RxD TermData CTS...

Страница 42: ...3 8...

Страница 43: ...for your C6R scanner Your C6R is shipped with the settings shown in the User Preferences Default Table on page 4 3 also see Appendix A Standard Default Parameters for all host device and miscellaneou...

Страница 44: ...one bar code to set a specific parameter value For example if you want to set the beeper tone to high simply scan the High Frequency beeper tone bar code listed under Beeper Tone on page 4 5 The scann...

Страница 45: ...ction beginning on page 4 4 Note See Appendix A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameters Table 4 1 User Preferences Default Table Par...

Страница 46: ...4 4 User Preferences Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table A 1 on page A 1 Set All Defaults...

Страница 47: ...5 User Preferences Beeper Tone To select a decode beep frequency tone scan the Low Frequency Medium Frequency or High Frequency bar code Low Frequency Medium Frequency Optimum Settings High Frequency...

Страница 48: ...4 6 Beeper Volume To select a beeper volume scan the Low Volume Medium Volume or High Volume bar code Low Volume Medium Volume High Volume...

Страница 49: ...wer remains on after a decode attempt When in reduced power mode the scanner enters into a low power consumption mode to preserve battery life after each decode attempt When in continuous power mode p...

Страница 50: ...3 0 seconds To set a Laser On Time scan the bar code below Next scan two numeric bar codes beginning on page D 1 in Appendix D that correspond to the desired on time Single digit numbers must have a...

Страница 51: ...to select whether or not the scanner beeps after a good decode If Do Not Beep After Good Decode is selected the beeper still operates during parameter menu scanning and indicates error conditions Bee...

Страница 52: ...4 10...

Страница 53: ...translates the bar code data into keystrokes The host computer accepts the keystrokes as if they originate from the keyboard This mode of operation allows adding bar code reading functionality to a s...

Страница 54: ...n page 1 3 3 Connect the round male DIN host connector of the Y cable to the keyboard port on the host device 4 Connect the round female DIN keyboard connector of the Y cable to the keyboard 5 If need...

Страница 55: ...e Host Default Table Parameter Default Page Number Keyboard Wedge Host Parameters Keyboard Wedge Host Type IBM PC AT IBM PC Compatibles1 5 4 Country Types Country Codes North American 5 5 Ignore Unkno...

Страница 56: ...es Select your keyboard wedge host by scanning one of the bar codes below IBM PC AT IBM PC Compatibles1 IBM PS 2 Model 30 IBM AT NOTEBOOK IBM XT NCR 7052 Note 1User selection is required to configure...

Страница 57: ...rd Wedge Country Types Country Codes Scan the bar code corresponding to your keyboard type If your particular keyboard type is not listed see Alternate Numeric Keypad Emulation on page 5 10 North Amer...

Страница 58: ...5 6 French Canadian Windows 95 98 French Canadian Windows XP 2000...

Страница 59: ...5 7 Keyboard Wedge Interface Keyboard Wedge Country Types continued Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows...

Страница 60: ...known Characters is selected all bar code data is sent except for unknown characters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar code dat...

Страница 61: ...face Keystroke Delay This is the delay in milliseconds between emulated keystrokes Scan a bar code below to increase the delay when hosts require a slower transmission of data No Delay Medium Delay 20...

Страница 62: ...troke Delay parameter to a minimum of 5 msec as well Enable Disable Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country T...

Страница 63: ...5 11 Keyboard Wedge Interface Caps Lock On When enabled the scanner emulates keystrokes as if the Caps Lock key is always pressed Enable Caps Lock On Disable Caps Lock On...

Страница 64: ...de is sent as an A no matter what the state of the keyboard s Caps Lock key Enable Caps Lock Override Disable Caps Lock Override Note If both Caps Lock On and Caps Lock Override are enabled Caps Lock...

Страница 65: ...ues under 32 are normally sent as control key sequences see Table 5 2 on page 5 18 When this parameter is enabled the keys in bold are sent in place of the standard key mapping Table entries that do n...

Страница 66: ...any FN1 characters in an EAN128 bar code with a keystroke chosen by the user see FN1 Substitution Values on page 13 9 Enable Disable Send Make and Break When enabled the scan codes for releasing a ke...

Страница 67: ...fix suffix values see the bar codes on page 13 5 Figure 5 2 IBM PS2 Type Keyboard Figure 5 3 IBM PC XT 7014 5001 7009 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 7008 7013 7011 7002 7012 70...

Страница 68: ...5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7009 7008 7013 7012 7004 7011 7003 7002 7014 5007 5008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 5001 5017 7013 5011...

Страница 69: ...5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 1086 1087 1088 1089 1090 5001 1066 1072 1073 1079 1080 1065 1070 1076 1077 1083 1084 1071 1078 1085 1069 5017 7013 5011 1082 1075...

Страница 70: ...scanned it is interpreted as b J as and V as Scanning ABC I outputs the keystroke equivalent of ABC Table 5 2 Keyboard Wedge ASCII Character Set ASCII Value Full ASCII Code 39 Encode Char Keystroke 10...

Страница 71: ...1020 T CTRL T 1021 U CTRL U 1022 V CTRL V 1023 W CTRL W 1024 X CTRL X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL ESC1 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035...

Страница 72: ...1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D Table 5 2 Keyboard...

Страница 73: ...2 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095...

Страница 74: ...01 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z Tabl...

Страница 75: ...2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2...

Страница 76: ...ey 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H...

Страница 77: ...GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 50...

Страница 78: ...F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 Table 5 2...

Страница 79: ...g Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow The keystroke in bo...

Страница 80: ...5 28...

Страница 81: ...computers or other devices with an available RS 232 port e g com port If your particular host is not listed in Table 6 2 you need to set the communication parameters to match your host device To set...

Страница 82: ...t the RS 232 interface cable to the bottom of the scanner as described in Installing the Interface Cable on page 1 3 2 Connect the other end of the interface cable to the serial port on the host 3 Con...

Страница 83: ...es and miscellaneous default parameters Table 6 1 RS 232 Host Default Table Parameter Default Page Number RS 232 Host Parameters RS 232 Host Types Standard1 6 7 Baud Rate 9600 6 10 Parity Type None 6...

Страница 84: ...Unknown Characters Send Bar Code 6 24 1 User selection is required to configure this interface and this is the most common selection Table 6 1 RS 232 Host Default Table Continued Parameter Default Pa...

Страница 85: ...00 9600 Parity None Even None Odd Odd Even None Hardware Handshaking None RTS CTS Option 3 None RTS CTS Option 3 RTS CTS Option 3 None None Software Handshaking None None None None None Ack Nak None S...

Страница 86: ...L Fujitsu Wincor Nixdorf Mode A Wincor Nixdorf Mode B OPOS Olivetti Omron UPC A A A A A A A UPC E E E C C C E EAN 8 JAN 8 FF FF B B B FF EAN 13 JAN 13 F F A A A F Code 39 C len None M M M len C len Co...

Страница 87: ...232 Interface RS 232 Host Types To select an RS 232 host interface scan one of the following bar codes Standard RS 2321 ICL RS 232 Wincor Nixdorf RS 232 Mode A Wincor Nixdorf RS 232 Mode B Olivetti O...

Страница 88: ...6 8 Omron OPOS JPOS Fujitsu RS 232 Note 1 User selection is required to configure this interface and this is the most common selection...

Страница 89: ...bits of data transmitted per second The scanner s baud rate setting should match the baud rate setting of the host device If not data may not reach the host device or may reach it in distorted form B...

Страница 90: ...6 10 Baud Rate continued Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400...

Страница 91: ...Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Odd Select Even parity and the parity bit value i...

Страница 92: ...6 12 Parity continued Select Space parity and the parity bit is always 0 Space Select None when no parity bit is required None...

Страница 93: ...for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to ma...

Страница 94: ...hether or not the parity framing and overrun of received characters are checked The parity value of received characters is verified against the parity parameter selected above Check For Received Error...

Страница 95: ...waits up to Host Serial Response Time out for the host to assert CTS When the host asserts CTS data is transmitted If after Host Serial Response Time out default the CTS line is not asserted the scann...

Страница 96: ...ts RTS before transmitting and ignores the state of CTS The scanner de asserts RTS when the transmission is complete RTS CTS Option 1 RTS CTS Option 2 When Option 2 is selected RTS is always high or l...

Страница 97: ...n error indication and discards the data The scanner de asserts RTS when transmission is complete RTS CTS Option 3 Software Handshaking This parameter offers control of the data transmission process i...

Страница 98: ...he programmable Host Serial Response Time out to receive an ACK or NAK If the scanner does not get a response in this time it issues an error indication and discards the data There are no retries when...

Страница 99: ...ON XOFF XOFF is received before the scanner has data to send When the scanner has data to send it waits up to Host Serial Response Time out for an XON character before transmission If the XON is not r...

Страница 100: ...scanner waits for an ACK NAK or CTS before determining that a transmission error has occurred This only applies when in one of the ACK NAK Software Handshaking modes or RTS CTS Hardware Handshaking op...

Страница 101: ...RTS or High RTS line state Host Low RTS Host High RTS Beep on BEL When this parameter is enabled the scanner issues a beep when a BEL character is detected on the RS 232 serial line BEL is issued to...

Страница 102: ...6 22 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions Minimum 0 msec Low 25 msec Medium 50 msec High 75 msec Maximum 99 msec...

Страница 103: ...eep LED Options When Nixdorf Mode B is selected this indicates when the scanner should beep and turn on its LED after a decode Normal Operation Beep LED immediately after decode Beep LED After Transmi...

Страница 104: ...all bar code data is send except for unknown characters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent up to the first un...

Страница 105: ...fix Suffix Values Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1000 U NUL 1001 A SOH 1002 B STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I...

Страница 106: ...1028 B FS 1029 C GS 1030 D RS 1031 E US 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O Table 6 4 Prefix Suffix Values Continued P...

Страница 107: ...054 6 6 1057 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I Table 6 4 Prefix Suffix Values Cont...

Страница 108: ...1 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c Table 6 4 Prefix Suffix Values Continued P...

Страница 109: ...J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R Table 6 4 Prefix Suffix Values...

Страница 110: ...6 30 1126 S 1127 Undefined 7013 ENTER Table 6 4 Prefix Suffix Values Continued Prefix Suffix Value Full ASCII Code 39 Encode Character ASCII Character...

Страница 111: ...er to a USB host The scanner attaches directly to a USB host or a powered USB hub and is powered by it No additional power supply is required Throughout the programming bar code menus default values a...

Страница 112: ...hat support more than one keyboard The following operating systems support the scanner through USB Windows 98 2000 ME XP MacOS 8 5 and above IBM 4690 OS The scanner will also interface with other USB...

Страница 113: ...pts you to select or install the Human Interface Device driver To install the Human Interface Device driver provided by Windows click Next through all the choices and click Finished on the last choice...

Страница 114: ...mbologies and miscellaneous default parameters Table 7 1 USB Host Default Table Parameter Default Page Number USB Host Parameters USB Device Type HID Keyboard Emulation 7 5 USB Country Keyboard Types...

Страница 115: ...USB Device Type Select the desired USB device type Note When changing USB Device Types the scanner automatically restarts The scanner issues the standard startup beep sequences IBM Table Top USB HID...

Страница 116: ...your keyboard type This setting applies only to the USB HID Keyboard Emulation device Note When changing Country Selection the scanner automatically restarts The scanner issues the standard startup be...

Страница 117: ...7 7 USB Interface USB Country Keyboard Types continued Spanish Windows Italian Windows French Canadian Windows 95 98 French Canadian Windows 2000 XP...

Страница 118: ...7 8 USB Country Keyboard Types continued Swedish Windows UK English Windows Japanese Windows ASCII Portuguese Brazilian Windows...

Страница 119: ...roke Delay This parameter sets the delay in milliseconds between emulated keystrokes Scan a bar code below to increase the delay when hosts require a slower transmission of data No Delay Long Delay 40...

Страница 120: ...ulation device When enabled the case of the data is preserved regardless of the state of the caps lock key This setting is always enabled for the Japanese Windows ASCII keyboard type and can not be di...

Страница 121: ...d Bar Codes With Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps sound When Do Not Send Bar Codes With Unknown Characters is selected bar code...

Страница 122: ...le Keypad Emulation Enable Keypad Emulation USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device When enabled this allows replacement of any FN 1 characters...

Страница 123: ...o not have a bold entry remain the same whether or not this parameter is enabled Disable Function Key Mapping Enable Function Key Mapping Simulated Caps Lock When enabled the scanner will invert upper...

Страница 124: ...7 14 Convert Case When enabled the scanner will convert all bar code data to the selected case No Case Conversion Convert All to Upper Case Convert All to Lower Case...

Страница 125: ...A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CT...

Страница 126: ...A CTRL ESC1 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1...

Страница 127: ...1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M...

Страница 128: ...1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h Tab...

Страница 129: ...9 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT...

Страница 130: ...2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z GUI Shift Keys The Apple iMac keyboard has an apple key on either side of the space bar Windows based...

Страница 131: ...3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 30...

Страница 132: ...U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F 12 5013 F 13 5014 F 14 5015...

Страница 133: ...9 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24 Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num L...

Страница 134: ...k 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Down Arrow 7017 Left Arrow 7018 Right Arrow The keystroke in bold is sent only if the Functi...

Страница 135: ...Introduction This chapter covers IBM 468X 469X host information for setting up your scanner Throughout the programming bar code menus default values are indicated with asterisks Disable Convert to Cod...

Страница 136: ...er as described in Installing the Interface Cable on page 1 3 2 Connect the other end of the interface cable to the appropriate port on the host typically Port 9 3 Scan the appropriate bar codes in th...

Страница 137: ...de s provided in the Parameter Descriptions section beginning on page 8 4 Note See Appendix A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameter...

Страница 138: ...Port Address This parameter sets the IBM 468X 469X port being used Note Scanning one of these bar codes enables the RS 485 interface on the scanner Non IBM Scanner Emulation Port 5B Hand held Scanner...

Страница 139: ...figure this interface and this is the most common selection Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39 Enable Convert...

Страница 140: ...8 6...

Страница 141: ...eeded The scanner will attach either to an external wand decoder or to a decoder integrated in a portable terminal or Point of Sale POS terminal In this mode the scanner emulates the signal of a digit...

Страница 142: ...9 1 Wand Emulation Connection 1 Connect the Wand Emulation interface cable to the bottom of the scanner as described in Installing the Interface Cable on page 1 3 2 Connect the other end of the interf...

Страница 143: ...user preferences hosts symbologies and miscellaneous default parameters Table 9 1 Wand Emulation Default Table Parameter Default Page Number Wand Emulation Host Parameters Wand Emulation Host Types S...

Страница 144: ...Select your wand emulation host by scanning one of the bar codes below Symbol OmniLink Interface Controller1 Symbol PDT Terminal MSI Symbol PTC Terminal Telxon Note 1User selection is required to con...

Страница 145: ...hat precedes the first bar of the scan in milliseconds The minimum allowed value is 80 msec and the maximum is 250 msec This parameter is used to accommodate older wand decoders which cannot handle sh...

Страница 146: ...Different decoders to which this device could be attached are expecting the DBP to be in a certain format The DBP either has the highs represent bars and the lows represent spaces margins or the high...

Страница 147: ...and Emulation Interface sends data to the attached host in the same symbology that was decoded This may present a problem for customers with older systems that do not recognize some newer symbologies...

Страница 148: ...ert to Code 39 for Wand Host Convert Code 39 to Full ASCII By default any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space If this parameter i...

Страница 149: ...er Undecoded Scanner Emulation communication is needed When Undecoded Scanner Emulation is used the scanner will attach either to an external decoder or to a decoder integrated in a portable terminal...

Страница 150: ...Undecoded interface cable to the bottom of the scanner as described in Installing the Interface Cable on page 1 3 2 Connect the other end of the interface cable to the scanner port on the portable dat...

Страница 151: ...1 Undecoded Scanner Emulation Default Table Parameter Default Page Number Beep Style Beep on Successful Transmit 10 5 Parameter Pass Through Parameter Process and Pass Through 10 6 Convert Newer Code...

Страница 152: ...10 4 Undecoded Scanner Emulation Host Scan the bar code below to enable the Undecoded Scanner Emulation Host Undecoded Scanner Emulation Host...

Страница 153: ...attached decoder beep at the same time The second option is to beep on the scanner s decode This results in a double beep sequence from most decoders since the scanner beeps and the decoder beeps at a...

Страница 154: ...mers using compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once Note Enabling D 2 of 5 for example can be performed simply by scanning the D...

Страница 155: ...e code types to more commonly decodable symbologies as per the following chart Symbologies not listed on this chart are transmitted normally When decoding these code types with this parameter disabled...

Страница 156: ...Module Width The standard module width is 20 s In the case of an extremely slow decoder system this module width can be extended to 50 s through use of this parameter 20 s Module Width 50 s Module Wi...

Страница 157: ...on By default any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space If this parameter is enabled the data sent to the Undecoded Scanner Emulati...

Страница 158: ...sion If after a specified amount of time the Decode signal has not been asserted indicating that the attached decoder has not successfully received the barcode data the scanner issues Transmit Error b...

Страница 159: ...r does not recognize When Ignore Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps are sounded When Convert Error on Unknown Characters is selec...

Страница 160: ...10 12 Leading Margin Scan a bar code below to select a leading margin duration 1 ms Leading Margin 2 ms Leading Margin 3 ms Leading Margin 5 ms Leading Margin 10 ms Leading Margin...

Страница 161: ...successfully decoded the transmitted barcode Some decoders however do not assert the Decode signal to tell the scanner that a decode has occurred In this case the scanner emits Transmit Error beeps to...

Страница 162: ...10 14...

Страница 163: ...application the scanner is programmed rather than modifying the host software Scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility Scanner programmi...

Страница 164: ...3Scan program load 123Scan included in the documentation CD ROM onto your PC and scan the bar code below Refer to 123Scan instructions for programming your scanner Note Scanning this bar code enables...

Страница 165: ...eatures values are set by scanning single bar codes or short bar code sequences To return all features to their default values all you need to do is scan the Set All Defaults bar code on page 4 4 If y...

Страница 166: ...at you scan several bar codes in the proper sequence Refer to the individual parameter like Set Length s for D 2 of 5 for this procedure Errors While Scanning Unless otherwise specified if you make an...

Страница 167: ...preferences hosts symbologies and miscellaneous default parameters Table 12 1 Symbology Default Table Parameter Default Page Number UPC EAN UPC A Enable 12 7 UPC E Enable 12 7 UPC E1 Disable 12 8 EAN...

Страница 168: ...ode Disable 12 24 Code 128 Code 128 Enable 12 25 UCC EAN 128 Enable 12 26 Code 39 Code 39 Enable 12 27 Trioptic Code 39 Disable 12 28 Convert Code 39 to Code 32 Italian Pharmacy Code Disable 12 29 Cod...

Страница 169: ...Disable 12 47 Interleaved 2 of 5 ITF Interleaved 2 of 5 ITF Enable 12 48 Set Lengths for I 2 of 5 14 12 49 I 2 of 5 Check Digit Verification Disable 12 51 Transmit I 2 of 5 Check Digit Disable 12 52...

Страница 170: ...4 MSI Check Digits One 12 66 Transmit MSI Check Digit Disable 12 67 MSI Check Digit Algorithm Mod 10 Mod 10 12 68 RSS Reduced Space Symbology RSS 14 Disable 12 69 RSS Limited Disable 12 69 RSS Expande...

Страница 171: ...12 7 Symbologies UPC EAN Enable Disable UPC A UPC E To enable or disable UPC A or UPC E scan the appropriate bar code below Enable UPC A Disable UPC A Enable UPC E Disable UPC E...

Страница 172: ...able Disable UPC E1 UPC E1 is disabled by default To enable or disable UPC E1 scan the appropriate bar code below Note UPC E1 is not a UCC Uniform Code Council approved symbology Enable UPC E1 Disable...

Страница 173: ...12 9 Symbologies Enable Disable EAN 13 EAN 8 To enable or disable EAN 13 or EAN 8 scan the appropriate bar code below Enable EAN 13 Disable EAN 13 Enable EAN 8 Disable EAN 8...

Страница 174: ...12 10 Enable Disable Bookland EAN To enable or disable Bookland EAN scan the appropriate bar code below Enable Bookland EAN Disable Bookland EAN...

Страница 175: ...EAN13 bar codes starting with a 378 or 379 prefix to be delayed by the supplemental search process All other UPC EAN bar codes are exempted from the search and are reported instantly upon their decode...

Страница 176: ...12 Decode UPC EAN JAN Supplementals Continued Ignore Supplementals Autodiscriminate UPC EAN JAN Supplementals Enable 378 379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart Supplemental Mo...

Страница 177: ...Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected The default is set at 7 Scan the bar code below to set a...

Страница 178: ...grity of the data Scan the appropriate bar code below to transmit the bar code data with or without the UPC A UPC E or UPC E1 check digit It is always verified to guarantee the integrity of the data T...

Страница 179: ...12 15 Symbologies Transmit UPC A UPC E UPC E1 Check Digit continued Transmit UPC E1 Check Digit Do Not Transmit UPC E1 Check Digit...

Страница 180: ...for transmitting UPC A preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Select the appropriate option to matc...

Страница 181: ...given for transmitting UPC E preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Select the appropriate option t...

Страница 182: ...for transmitting UPC E1 preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Select the appropriate option to mat...

Страница 183: ...o UPC A format before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit When disabled UPC E decoded data is transmitt...

Страница 184: ...before transmission After conversion the data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit When disabled UPC E1 decoded data is transmitted as UPC E1 d...

Страница 185: ...d When enabled this parameter adds five leading zeros to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols When disabled EAN 8 symbols are transmitted as is Enable EAN JAN Zero...

Страница 186: ...for any given application UPC EAN Security Level 0 This is the default setting which allows the scanner to operate fastest while providing sufficient security in decoding in spec UPC EAN bar codes UPC...

Страница 187: ...ty Level 3 If you have tried Security Level 2 and are still experiencing misdecodes select this security level Be advised selecting this option is an extreme measure against misdecoding severely out o...

Страница 188: ...ting with digit 99 and UPCA EAN 128 Coupon Codes UPCA EAN 13 and EAN 128 must be enabled to scan all types of Coupon Codes Enable UCC Coupon Extended Code Disable UCC Coupon Extended Code Note Autodis...

Страница 189: ...12 25 Symbologies Code 128 Enable Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below Enable Code 128 Disable Code 128...

Страница 190: ...12 26 Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below Enable UCC EAN 128 Disable UCC EAN 128...

Страница 191: ...12 27 Symbologies Code 39 Enable Disable Code 39 To enable or disable Code 39 scan the appropriate bar code below Enable Code 39 Disable Code 39...

Страница 192: ...marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Trioptic Code 39 scan the appropriate bar code below Enable Trioptic Code 39 Disable Tri...

Страница 193: ...39 used by the Italian pharmaceutical industry Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Note Code 39 must be enabled in order for this parameter to funct...

Страница 194: ...e appropriate bar code below to enable or disable adding the prefix character A to all Code 32 bar codes Note Convert Code 39 to Code 32 must be enabled for this parameter to function Enable Code 32 P...

Страница 195: ...containing a selected length Lengths are selected from the numeric bar codes beginning on page D 1 in Appendix D For example to decode only Code 39 symbols with 14 characters scan Code 39 One Discret...

Страница 196: ...code Code 39 symbols containing between 4 and 12 characters first scan Code 39 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero If you make an e...

Страница 197: ...ymbols to verify that the data complies with specified check digit algorithm Only those Code 39 symbols which include a modulo 43 check digit are decoded when this feature is enabled This feature shou...

Страница 198: ...a bar code below to transmit Code 39 data with or without the check digit Transmit Code 39 Check Digit Enable Do Not Transmit Code 39 Check Digit Disable Note Code 39 Check Digit Verification must be...

Страница 199: ...g of Code 39 characters to ASCII values Enable Code 39 Full ASCII Disable Code 39 Full ASCII Note Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously Note Code 39 Full ASCII to Fu...

Страница 200: ...triggering symbol See the following pages for further details When the Do Not Buffer Code 39 option is selected all decoded Code 39 symbols are transmitted immediately without being stored in the buff...

Страница 201: ...uffer The scanner adds the decoded data excluding the leading space to the transmission buffer No transmission occurs Clear Transmission Buffer To clear the transmission buffer scan the Clear Buffer b...

Страница 202: ...The scanner transmits and clears the buffer The scanner signals that the buffer was transmitted with a lo hi beep Scanner transmits and clears the buffer Note The Transmit Buffer contains only a plus...

Страница 203: ...mpt to Transmit an Empty Buffer If the symbol just read was the Transmit Buffer symbol and the Code 39 buffer is empty A short lo hi lo beep signals that the buffer is empty No transmission occurs The...

Страница 204: ...12 40 Code 93 Enable Disable Code 93 To enable or disable Code 93 scan the appropriate bar code below Enable Code 93 Disable Code 93...

Страница 205: ...le to decode only Code 93 symbols with 14 characters scan Code 93 One Discrete Length then scan 1 followed by 4 If you make an error or wish to change your selection scan Cancel on page D 5 Code 93 On...

Страница 206: ...ode Code 93 symbols containing between 4 and 12 characters first scan Code 93 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero If you make an er...

Страница 207: ...12 43 Symbologies Code 11 Code 11 To enable or disable Code 11 scan the appropriate bar code below Enable Code 11 Disable Code 11...

Страница 208: ...decode only Code 11 symbols with 14 characters scan Code 11 One Discrete Length then scan 1 followed by 4 If you make an error or wish to change your selection scan Cancel on page D 5 Code 11 One Disc...

Страница 209: ...to decode Code 11 symbols containing between 4 and 12 characters first scan Code 11 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero If you mak...

Страница 210: ...ecified check digit algorithm This selects the check digit mechanism for the decoded Code 11 bar code The options are to check for one check digit check for two check digits or disable the feature To...

Страница 211: ...ts This feature selects whether or not to transmit the Code 11 check digit s Transmit Code 11 Check Digit s Enable Do Not Transmit Code 11 Check Digit s Disable Note Code 11 Check Digit Verification m...

Страница 212: ...Enable Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5 scan the appropriate bar code below and select an Interleaved 2 of 5 length from the following pages Enable Interleaved 2 of...

Страница 213: ...ample to decode only I 2 of 5 symbols with 14 characters scan I 2 of 5 One Discrete Length then scan 1 followed by 4 If you make an error or wish to change your selection scan Cancel on page D 5 I 2 o...

Страница 214: ...If you make an error or wish to change your selection scan Cancel on page D 5 I 2 of 5 Length Within Range Any Length Scanning this option allows you to decode I 2 of 5 symbols containing any number...

Страница 215: ...ure is enabled the scanner checks the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification USS or the Optical Product Code Council OP...

Страница 216: ...Transmit I 2 of 5 Check Digit Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit Transmit I 2 of 5 Check Digit Enable Do Not Transmit I 2 of 5 Check Digit Di...

Страница 217: ...to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled and the code must have a leading zero and a valid EAN 13 check digit Scanning a single bar code below Convert I 2 o...

Страница 218: ...12 54 Discrete 2 of 5 DTF Enable Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5 scan the appropriate bar code below Enable Discrete 2 of 5 Disable Discrete 2 of 5...

Страница 219: ...mple to decode only D 2 of 5 symbols with 14 characters scan D 2 of 5 One Discrete Length then scan 1 followed by 4 If you make an error or wish to change your selection scan Cancel on page D 5 D 2 of...

Страница 220: ...If you make an error or wish to change your selection scan Cancel on page D 5 D 2 of 5 Length Within Range Any Length Scanning this option allows you to decode D 2 of 5 symbols containing any number o...

Страница 221: ...12 57 Symbologies Chinese 2 of 5 Enable Disable Chinese 2 of 5 To enable or disable Chinese 2 of 5 scan the appropriate bar code below Enable Chinese 2 of 5 Disable Chinese 2 of 5...

Страница 222: ...12 58 Codabar NW 7 Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below Enable Codabar Disable Codabar...

Страница 223: ...le to decode only Codabar symbols with 14 characters scan Codabar One Discrete Length then scan 1 followed by 4 If you make an error or wish to change your selection scan Cancel on page D 5 Codabar On...

Страница 224: ...code Codabar symbols containing between 4 and 12 characters first scan Codabar Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero If you make an e...

Страница 225: ...stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Enable this feature if your host system requires this data format Note Symbol length doe...

Страница 226: ...Editing When enabled this parameter strips the start and stop characters from a decoded Codabar symbol Enable this feature if your host system requires this data format Enable NOTIS Editing Disable NO...

Страница 227: ...12 63 Symbologies MSI Enable Disable MSI To enable or disable MSI scan the appropriate bar code below Enable MSI Disable MSI...

Страница 228: ...mple to decode only MSI symbols with 14 characters scan MSI One Discrete Length then scan 1 followed by 4 If you make an error or wish to change your selection scan Cancel on page D 5 MSI One Discrete...

Страница 229: ...g zero If you make an error or wish to change your selection scan Cancel on page D 5 MSI Length Within Range Any Length Scanning this option allows you to decode MSI symbols containing any number of c...

Страница 230: ...ader The second check digit is optional If your MSI codes include two check digits enable the verification of the second check digit by scanning the barcode below Refer to MSI Check Digit Algorithm on...

Страница 231: ...12 67 Symbologies Transmit MSI Check Digit s Scan a bar code below to transmit MSI data with or without the check digit Transmit MSI Check Digit s Enable Do Not Transmit MSI Check Digit s Disable...

Страница 232: ...k Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit Select the bar code below corresponding to the algorithm used to encode your check digit MOD 10 MOD 11...

Страница 233: ...Symbology RSS The variants of RSS are RSS 14 RSS Expanded and RSS Limited The limited and expanded versions have stacked variants Scan the appropriate bar code below to enable or disable each variant...

Страница 234: ...12 70 RSS continued Enable RSS Limited Disable RSS Limited Enable RSS Expanded Disable RSS Expanded...

Страница 235: ...ngle zero as the first digit have the leading 010 stripped and the bar code reported as EAN 13 Bar codes beginning with two or more zeros but not six zeros have the leading 0100 stripped and the bar c...

Страница 236: ...els increase the scanner s aggressiveness decreases Select the redundancy level appropriate for the bar code quality Redundancy Level 1 The following code types must be successfully read twice before...

Страница 237: ...ancy Level 3 Code types other than the following must be successfully read twice before being decoded The following codes must be read three times REDUNDANCY LEVEL 3 Code Type Code Length All All Code...

Страница 238: ...12 74 Redundancy Level 4 The following code types must be successfully read three times before being decoded REDUNDANCY LEVEL 4 Code Type Code Length All All...

Страница 239: ...tionship between security and scanner aggressiveness so be sure to choose only that level of security necessary for any given application Security Level 0 This is the default setting which allows the...

Страница 240: ...nd misdecodes are still occurring select this security level Be advised selecting this option is an extreme measure against mis decoding severely out of spec bar codes Selection of this level of secur...

Страница 241: ...dundancy is used for added security to linear code type security levels When enabled a bar code must be successfully scanned in both directions forward and reverse before reporting a good decode Enabl...

Страница 242: ...us barcode printing technologies this gap may grow larger than the maximum size allowed causing the scanner to be unable to decode the symbol If this problem is encountered then the Large Intercharact...

Страница 243: ...ogies and Chapter 14 Advanced Data Formatting for customizing data for transmission to your host device Before programming follow the instructions in Chapter 1 Getting Started Your scanner is shipped...

Страница 244: ...r value Parameters such as Prefix Value require that you scan several bar codes in the proper sequence Refer to each individual parameter for descriptions of this procedure Errors While Scanning Unles...

Страница 245: ...See Appendix A Standard Default Parameters for all user preferences hosts symbologies and miscellaneous default parameters Table 13 1 Miscellaneous Scanner Options Default Table Parameter Default Pag...

Страница 246: ...code type In addition to any single character prefix already selected the Code ID character is inserted between the prefix and the decoded symbol The user may select no Code ID character a Symbol Code...

Страница 247: ...ese values are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table E 1 on page E 1 for conversion information Numeric bar codes begin o...

Страница 248: ...DATA SUFFIX PREFIX DATA PREFIX DATA SUFFIX When you have made your selection scan the Enter bar code on page 13 8 If you make a mistake scan the Data Format Cancel bar code on page 13 8 If you need to...

Страница 249: ...13 7 Miscellaneous Scanner Options Scan Data Transmission Format continued Data As Is DATA SUFFIX PREFIX DATA...

Страница 250: ...13 8 Scan Data Transmission Format continued PREFIX DATA SUFFIX Enter Data Format Cancel...

Страница 251: ...1 Substitution Value 2 Look up the keystroke desired for FN1 Substitution in the ASCII Character Set table for the currently installed host interface Enter the 4 digit ASCII Value by scanning each dig...

Страница 252: ...e below to select whether or not a No Read message is transmitted When enabled the characters NR are transmitted when a bar code is not decoded When disabled if a symbol does not decode nothing is sen...

Страница 253: ...onnection should be used In all other cases where the cable is used the default setting is recommended Should the user want to disconnect and reconnect the scanner from a Synapse cable that is connect...

Страница 254: ...13 12...

Страница 255: ...utility see Chapter 11 123Scan which allows the scanner to be setup and programmed with Advanced Data Formatting ADF Rules Note If you are using the Wand interface with your scanner you will not be ab...

Страница 256: ...le bar code on page 14 8 Criteria Scan the bar codes for all pertinent criteria Criteria can include code type e g Code 128 code length or data that contains a specific character string e g the digits...

Страница 257: ...acturer ID P Part Number D Destination Code The distribution center uses a PC with dedicated control characters for manufacturer ID CTRL M part number CTRL P and destination code CTRL D At this center...

Страница 258: ...UPC EAN 14 13 High High 3 Send all remaining data 14 25 High High 4 Send CTRL M 14 47 High High 5 Save Rule 14 9 High Low High Low If you made any mistakes while entering this rule scan the Quit Enter...

Страница 259: ...key send the data that remains send the Enter key The sale rule may look like this When scanning a bar code of length 15 send the next 2 characters send the class key send the next 8 characters send...

Страница 260: ...ist If three rules have been created the list would be configured as follows Third Rule Second Rule First Rule When data is scanned the rules list is checked from top to bottom to determine if the cri...

Страница 261: ...important Default Rules Every unit has a default rule to send all scan data Units with custom software may have one or more default rules burned in The rules hierarchy checks user programmable rules f...

Страница 262: ...i e two bar codes and are measured in 0 1 second intervals For example scanning bar codes 0 and 1 inserts a 0 1 second pause 0 and 5 gives you a 0 5 second delay Numeric bar codes begin on page D 1 i...

Страница 263: ...ve Rule Scan this bar code to save the rule you entered Erase Use these bar codes to erase criteria actions or rules Save Rule Erase Criteria And Start Again Erase Actions And Start Again Erase Previo...

Страница 264: ...14 10 Quit Entering Rules Scan this bar code to quit entering rules Quit Entering Rules...

Страница 265: ...14 11 Advanced Data Formatting Disable Rule Set Use these bar codes to disable rule sets Disable Rule Set 1 Disable Rule Set 2 Disable Rule Set 4 Disable Rule Set 3 Disable All Rule Sets...

Страница 266: ...r of code types to be affected All selected codes must be scanned in succession prior to selecting other criteria If you don t select a code type all code types will be affected Code 39 Codabar 6C13D2...

Страница 267: ...14 13 Advanced Data Formatting Scan the bar codes for all code types desired before selecting other criteria I 2 OF 5 UPC A D 2 OF 5 UPC E EAN 8 IATA 2 OF 5 Code 93 EAN 13...

Страница 268: ...14 14 Code Types continued UCC EAN 128 MSI UPC E1 Bookland EAN Trioptic Code 39 Chinese 2 of 5 Coupon Code...

Страница 269: ...must contain If you don t select a code length selected code types of any length will be affected Scan these bar codes to define the number of characters the selected code types must contain Select on...

Страница 270: ...14 16 7 Characters 8 Characters 9 Characters 10 Characters 11 Characters 12 Characters...

Страница 271: ...14 17 Advanced Data Formatting Code Lengths continued 13 Characters 15 Characters 16 Characters 14 Characters 17 Characters 18 Characters...

Страница 272: ...14 18 Code Lengths continued 20 Characters 19 Characters 21 Characters 23 Characters 24 Characters 22 Characters...

Страница 273: ...14 19 Advanced Data Formatting Code Lengths continued 25 Characters 26 Characters 28 Characters 27 Characters 29 Characters 30 Characters...

Страница 274: ...cific String at Start Specific String Any Location Any Message OK Rule Belongs to Set Specific String at Start Scan this bar code then scan the bar codes representing the desired character or characte...

Страница 275: ...total of 8 on the Alphanumeric Keyboard on page 14 84 followed by the End Of Message bar code on page 14 90 After scanning the following bar code 1 Enter a location using the Numeric Keypad on page 14...

Страница 276: ...14 22 Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard 0 1 3 2 4 5 7 9 6 8 Cancel...

Страница 277: ...belongs to There are four possible rule sets Refer to Alternate Rule Sets on page 14 4 for more information about rule sets Scan a bar code below to select which set a rule belongs to Rule Belongs To...

Страница 278: ...or transmission Send Data Send all data that remains send all data up to a specific character selected from the Alphanumeric Keyboard on page 14 84 or send the next N characters N any number from 1 to...

Страница 279: ...se bar codes to send data Send All Data That Re mains Send Next Character Send Next 3 Characters Send Next 2 Characters Send Next 4 Characters Send Next 5 Characters Send Next 7 Characters Send Next 6...

Страница 280: ...ext 8 Characters Send Next 9 Characters Send Next 11 Characters Send Next 10 Characters Send Next 12 Characters Send Next 13 Characters Send Next 15 Characters Send Next 14 Characters Send Next 16 Cha...

Страница 281: ...14 27 Advanced Data Formatting Send Data continued Send Next 19 Characters Send Next 18 Characters Send Next 20 Characters...

Страница 282: ...nces of a selected character For example if the selected character is A then the cursor moves past A AA AAA etc Scan the Move Cursor Past Character bar code on page 14 29 then select a character from...

Страница 283: ...ric Keyboard beginning on page 14 84 Note If there is no match when the rule is interpreted and the rule fails the next rule is checked Send Pause Scan the bar code below to insert a pause in the tran...

Страница 284: ...wing bar codes to skip ahead characters Skip Ahead 2 Characters Skip Ahead 4 Characters Skip Ahead 1 Character Skip Ahead 3 Characters Skip Ahead 5 Characters Skip Ahead 6 Characters Skip Ahead 8 Char...

Страница 285: ...14 31 Advanced Data Formatting Skip Ahead continued Skip Ahead 9 Characters Skip Ahead 10 Characters...

Страница 286: ...llowing bar codes to skip back characters Skip Back 1 Characters Skip Back 3 Characters Skip Back 2 Characters Skip Back 4 Characters Skip Back 6 Characters Skip Back 5 Characters Skip Back 7 Characte...

Страница 287: ...14 33 Advanced Data Formatting Skip Back continued Skip Back 9 Characters Skip Back 10 Characters...

Страница 288: ...actions work for all send commands that follow it within a rule If you program pad zeros to length 6 send next 3 characters stop padding send next 5 characters three zeros are added to the first send...

Страница 289: ...Crunch All Spaces To leave one space between words scan this bar code This also removes all leading and trailing spaces Stop Space Removal Scan this bar code to disable space removal Remove Leading Z...

Страница 290: ...14 36 Use the bar codes below to modify data Remove All Spaces Crunch All Spaces Remove Leading Zeros Stop Space Removal Stop Zero Removal...

Страница 291: ...the bar code containing the desired number of spaces This parameter is activated by Send commands Pad Spaces To Length 1 Pad Spaces To Length 2 Pad Spaces To Length 4 Pad Spaces To Length 3 Pad Spaces...

Страница 292: ...with Spaces continued Pad Spaces To Length 9 Pad Spaces To Length 10 Pad Spaces To Length 12 Pad Spaces To Length 11 Pad Spaces To Length 13 Pad Spaces To Length 14 Pad Spaces To Length 16 Pad Spaces...

Страница 293: ...ing Pad Data with Spaces continued Pad Spaces To Length 17 Pad Spaces To Length 18 Pad Spaces To Length 20 Pad Spaces To Length 19 Pad Spaces To Length 21 Pad Spaces To Length 22 Pad Spaces To Length...

Страница 294: ...14 40 Pad Data with Spaces continued Pad Spaces To Length 25 Pad Spaces To Length 26 Pad Spaces To Length 28 Pad Spaces To Length 27 Pad Spaces To Length 29 Pad Spaces To Length 30 Stop Pad Spaces...

Страница 295: ...can the bar code containing the desired number of zeros This parameter is activated by Send commands Pad Zeros To Length 1 Pad Zeros To Length 2 Pad Zeros To Length 4 Pad Zeros To Length 3 Pad Zeros T...

Страница 296: ...Data with Zeros continued Pad Zeros To Length 9 Pad Zeros To Length 10 Pad Zeros To Length 12 Pad Zeros To Length 11 Pad Zeros To Length 13 Pad Zeros To Length 14 Pad Zeros To Length 15 Pad Zeros To...

Страница 297: ...rmatting Pad Data with Zeros continued Pad Zeros To Length 17 Pad Zeros To Length 19 Pad Zeros To Length 18 Pad Zeros To Length 20 Pad Zeros To Length 21 Pad Zeros To Length 23 Pad Zeros To Length 22...

Страница 298: ...14 44 Pad Data with Zeros continued Pad Zeros To Length 25 Pad Zeros To Length 27 Pad Zeros To Length 26 Pad Zeros To Length 28 Pad Zeros To Length 29 Stop Pad Zeros Pad Zeros To Length 30...

Страница 299: ...14 45 Advanced Data Formatting Beeps Select a beep sequence for each ADF rule Beep Once Beep Twice Beep Three Times...

Страница 300: ...racters and Keyboard Characters Control Characters Scan the Send __ bar code for the keystroke you wish to send Send Control 2 Send Control A Send Control C Send Control B Send Control D Send Control...

Страница 301: ...14 47 Advanced Data Formatting Control Characters continued Send Control H Send Control I Send Control K Send Control J Send Control L Send Control M Send Control O Send Control N...

Страница 302: ...14 48 Control Characters continued Send Control P Send Control Q Send Control S Send Control R Send Control T Send Control U Send Control W Send Control V...

Страница 303: ...14 49 Advanced Data Formatting Control Characters continued Send Control X Send Control Y Send Control Send Control Z Send Control Send Control Send Control Send Control 6...

Страница 304: ...14 50 Keyboard Characters Scan the Send __ bar code for the keyboard characters you wish to send Send Space Send Send Send Send Send Send Send...

Страница 305: ...14 51 Advanced Data Formatting Keyboard Characters continued Send Send Send Send Send Send Send Send...

Страница 306: ...14 52 Keyboard Characters continued Send 0 Send 1 Send 3 Send 2 Send 4 Send 5 Send 7 Send 6...

Страница 307: ...14 53 Advanced Data Formatting Keyboard Characters continued Send 8 Send 9 Send Send Send Send Send Send...

Страница 308: ...14 54 Keyboard Characters continued Send Send A Send C Send B Send D Send E Send G Send F...

Страница 309: ...14 55 Advanced Data Formatting Keyboard Characters continued Send H Send I Send K Send J Send L Send M Send O Send N...

Страница 310: ...14 56 Keyboard Characters continued Send P Send Q Send S Send R Send T Send U Send W Send V...

Страница 311: ...14 57 Advanced Data Formatting Keyboard Characters continued Send X Send Y Send Send Z Send Send Send _ Send...

Страница 312: ...14 58 Keyboard Characters continued Send Send a Send c Send b Send d Send e Send g Send f...

Страница 313: ...14 59 Advanced Data Formatting Keyboard Characters continued Send h Send i Send k Send j Send l Send m Send o Send n...

Страница 314: ...14 60 Keyboard Characters continued Send p Send q Send s Send r Send t Send u Send w Send v...

Страница 315: ...14 61 Advanced Data Formatting Keyboard Characters continued Send x Send y Send Send z Send Send Send...

Страница 316: ...14 62 Send ALT Characters Send Alt 2 Send Alt A Send Alt C Send Alt B Send Alt D Send Alt E Send Alt G Send Alt F...

Страница 317: ...14 63 Advanced Data Formatting Send ALT Characters continued Send Alt H Send Alt I Send Alt K Send Alt J Send Alt L Send Alt M Send Alt O Send Alt N...

Страница 318: ...14 64 Send ALT Characters continued Send Alt P Send Alt Q Send Alt S Send Alt R Send Alt T Send Alt U Send Alt W Send Alt V...

Страница 319: ...14 65 Advanced Data Formatting Send ALT Characters continued Send Alt X Send Alt Y Send Alt Send Alt Z Send Alt Send Alt Send Alt Send Alt 6...

Страница 320: ...14 66 Send Keypad Characters Send Keypad Send Keypad Send Keypad Send Keypad Send Keypad Send Keypad 0 Send Keypad 2 Send Keypad 1 Send Keypad 4 Send Keypad 3...

Страница 321: ...14 67 Advanced Data Formatting Send Keypad Characters continued Send Keypad 5 Send Keypad 6 Send Keypad 8 Send Keypad 7 Send Keypad 9 Send Keypad Enter Send Keypad Numlock...

Страница 322: ...8 Send Keypad Characters continued Send Break Key Send Delete Key Send End Key Send Page Up Key Send Page Down Key Send Pause Key Send Backspace Key Send Scroll Lock Key Send Print Screen Key Send Tab...

Страница 323: ...69 Advanced Data Formatting Send Keypad Characters continued Send Insert Key Send Enter Key Send Up Arrow Key Send Left Arrow Key Send Home Key Send Escape Key Send Down Arrow Key Send Right Arrow Ke...

Страница 324: ...14 70 Send Function Key Send F1 Key Send F2 Key Send F4 Key Send F3 Key Send F5 Key Send F6 Key Send F8 Key Send F7 Key Send F10 Key Send F9 Key...

Страница 325: ...14 71 Advanced Data Formatting Send Function Key continued Send F11 Key Send F12 Key Send F14 Key Send F13 Key Send F15 Key Send F16 Key Send F18 Key Send F17 Key Send F20 Key Send F19 Key...

Страница 326: ...14 72 Send Function Key continued Send F21 Key Send F22 Key Send F24 Key Send F23 Key...

Страница 327: ...14 73 Advanced Data Formatting Send Function Key continued Send PF1 Key Send PF2 Key Send PF4 Key Send PF3 Key Send PF5 Key Send PF6 Key Send PF8 Key Send PF7 Key Send PF10 Key Send PF9 Key...

Страница 328: ...14 74 Send Function Key continued Send PF11 Key Send PF12 Key Send PF14 Key Send PF13 Key Send PF15 Key Send PF16 Key Send PF18 Key Send PF17 Key Send PF20 Key Send PF19 Key...

Страница 329: ...14 75 Advanced Data Formatting Send Function Key continued Send PF21 Key Send PF22 Key Send PF24 Key Send PF23 Key Send PF25 Key Send PF26 Key Send PF28 Key Send PF27 Key Send PF30 Key Send PF29 Key...

Страница 330: ...t Control Key Send Graphic User Interface GUI Characters The Send Graphic User Interface Character actions will tap the specified key while holding the System Dependent Graphic User Interface GUI Key...

Страница 331: ...14 77 Advanced Data Formatting Send GUI 5 Send GUI 6 Send GUI 4 Send GUI 7 Send GUI 8 Send GUI 9...

Страница 332: ...14 78 Send GUI A Send GUI B Send GUI C Send GUI D Send GUI E Send GUI F...

Страница 333: ...14 79 Advanced Data Formatting Send GUI G Send GUI H Send GUI I Send GUI J Send GUI K Send GUI L...

Страница 334: ...14 80 Send GUI M Send GUI N Send GUI O Send GUI P Send GUI Q Send GUI R...

Страница 335: ...14 81 Advanced Data Formatting Send GUI S Send GUI T Send GUI V Send GUI W Send GUI X Send GUI U...

Страница 336: ...14 82 Send GUI Y Send GUI Z...

Страница 337: ...g Turn On Off Rule Sets Use these bar codes to turn rule sets on and off Turn On Rule Set 1 Turn On Rule Set 2 Turn On Rule Set 4 Turn On Rule Set 3 Turn Off Rule Set 1 Turn Off Rule Set 2 Turn Off Ru...

Страница 338: ...14 84 Alphanumeric Keyboard Space Dash...

Страница 339: ...14 85 Advanced Data Formatting Alphanumeric Keyboard continued...

Страница 340: ...14 86 Alphanumeric Keyboard continued _ Underscore...

Страница 341: ...14 87 Advanced Data Formatting Alphanumeric Keyboard continued Bar codes on this page should not be confused with those on the numeric keypad 0 1 3 2 4 5 7 6 9 8...

Страница 342: ...14 88 Alphanumeric Keyboard continued A B D C E F H G J I...

Страница 343: ...14 89 Advanced Data Formatting Alphanumeric Keyboard continued K L N M O P R Q T S...

Страница 344: ...14 90 Alphanumeric Keyboard continued U V X W Y Z End Of Message Cancel...

Страница 345: ...14 91 Advanced Data Formatting Alphanumeric Keyboard continued a b d c e f h g j i...

Страница 346: ...14 92 Alphanumeric Keyboard continued k l n m o p r q t s...

Страница 347: ...14 93 Advanced Data Formatting Alphanumeric Keyboard continued u v x w y z...

Страница 348: ...14 94...

Страница 349: ...4 Beeper Tone Medium 4 5 Beeper Volume High 4 6 Power Mode Continuous On 4 7 Laser On Time 3 0 Sec 4 8 Beep After Good Decode Enable 4 9 Keyboard Wedge Host Parameters Keyboard Wedge Host Type IBM PC...

Страница 350: ...N1 Substitution Disable 5 14 Send and Make Break Send 5 14 RS 232 Host Parameters RS 232 Host Types Standard1 6 7 Baud Rate 9600 6 10 Parity Type None 6 12 Stop Bit Select 1 Stop Bit 6 13 Data Bits 8...

Страница 351: ...odes North American 7 6 USB Keystroke Delay No Delay 7 9 USB CAPS Lock Override Disable 7 10 USB Ignore Unknown Characters Enable 7 10 Emulate Keypad Disable 7 12 USB Keyboard FN1 Substitution Disable...

Страница 352: ...d Scanner Emulation Beep Style Beep on Successful Transmit 10 5 Parameter Pass Through Parameter Process and Pass Through 10 6 Convert Newer Code Types Convert Newer Code Types 10 7 Module Width 20 s...

Страница 353: ...le 12 9 EAN 13 JAN 13 Enable 12 9 Bookland EAN Disable 12 10 Decode UPC EAN JAN Supplementals 2 and 5 digits Ignore 12 12 UPC EAN JAN Supplemental Redundancy 7 12 13 Transmit UPC A Check Digit Enable...

Страница 354: ...6 Code 39 Code 39 Enable 12 27 Trioptic Code 39 Disable 12 28 Convert Code 39 to Code 32 Italian Pharmacy Code Disable 12 29 Code 32 Prefix Disable 12 30 Set Length s for Code 39 2 to 55 12 31 Code 39...

Страница 355: ...aved 2 of 5 ITF Interleaved 2 of 5 ITF Enable 12 48 Set Lengths for I 2 of 5 14 12 49 I 2 of 5 Check Digit Verification Disable 12 51 Transmit I 2 of 5 Check Digit Disable 12 52 Convert I 2 of 5 to EA...

Страница 356: ...ransmit MSI Check Digit Disable 12 67 MSI Check Digit Algorithm Mod 10 Mod 10 12 68 RSS Reduced Space Symbology RSS 14 Disable 12 69 RSS Limited Disable 12 70 RSS Expanded Disable 12 70 Convert RSS to...

Страница 357: ...e 7013 CR LF 13 5 Scan Data Transmission Format Data as is 13 7 FN1 Substitution Values Set 13 9 Transmit No Read Message Disable 13 10 Synapse Interface Standard 13 11 Table A 1 Standard Default Para...

Страница 358: ...A 10...

Страница 359: ...le B 1 Code Characters Code Character Code Type A UPC A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code...

Страница 360: ...B 2 L N Coupon Code R RSS Family T UCC Composite TLC 39 Table B 1 Code Characters Continued Code Character Code Type...

Страница 361: ...ode Character see Table B 2 m Modifier Character see Table B 3 Table B 2 Aim Code Characters Code Character Code Type A Code 39 Code 39 Full ASCII Code 32 C Code 128 Coupon Code 128 portion E UPC EAN...

Страница 362: ...Trioptic Code 39 0 No option specified at this time Always transmit 0 Example A Trioptic bar code 412356 is transmitted as X0412356 Code 128 0 Standard data packet no Function code 1 in first symbol...

Страница 363: ...ted as S04123 UPC EAN 0 Standard packet in full EAN country code format which is 13 digits for UPC A and UPC E not including supplemental data 1 Two digit supplement data only 2 Five digit supplement...

Страница 364: ...B 6...

Страница 365: ...C 1 0 12345 67890 5 Appendix C Sample Bar Codes Code 39 UPC EAN UPC A 100 123ABC...

Страница 366: ...C 2 UPC EAN continued EAN 13 100 Code 128 Interleaved 2 of 5 3 456789 012340 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 12345678901231...

Страница 367: ...C 3 Sample Bar Codes RSS 14 Note RSS 14 must be enabled to read the bar code below see Enable RSS 14 on page 12 69 7612341562341...

Страница 368: ...C 4...

Страница 369: ...D 1 Appendix D Numeric Bar Codes 0 1 For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1...

Страница 370: ...D 2 2 3 4 2 3 4...

Страница 371: ...D 3 Numeric Bar Codes 5 6 7 5 6 7...

Страница 372: ...D 4 8 9 9 8...

Страница 373: ...D 5 Numeric Bar Codes Cancel If you make an error or wish to change your selection scan the bar code below Cancel...

Страница 374: ...D 6...

Страница 375: ...nt in a printed bar code symbol Bar Code Density The number of characters represented per unit of measurement e g characters per inch Bar Height The dimension of a bar measured perpendicular to the ba...

Страница 376: ...tuation mark or communications control contained in a message Character Set Those characters available for encoding in a particular bar code symbology Check Digit A digit used to verify a correct symb...

Страница 377: ...ymbol in which the spaces between characters intercharacter gaps are not part of the code Discrete 2 of 5 A binary bar code symbology representing each character by a group of five bars two of which a...

Страница 378: ...of Radiation The laser is an intense light source Light from a laser is all the same frequency unlike the output of an incandescent bulb Laser light is typically coherent and has a high energy densit...

Страница 379: ...particular device or method RSS Reduced Space Symbology A family of space efficient symbologies developed by UCC EAN Scan Area Area intended to contain a symbol Scanner An electronic device used to sc...

Страница 380: ...ght The distance between the outside edges of the quiet zones of the first row and the last row Symbol Length Length of symbol measured from the beginning of the quiet zone margin adjacent to the star...

Страница 381: ...ers 14 66 send preset value 14 28 send value 14 34 skip ahead characters 14 30 skip ahead n characters 14 28 skip back characters 14 32 skip back n characters 14 28 space removal 14 34 special command...

Страница 382: ...ternate numeric keypad emulation 5 10 caps lock on 5 11 capsl ock override 5 12 country keyboard types country codes 5 5 default table 5 3 host types 5 4 ignore unknown characters 5 8 intra keystroke...

Страница 383: ...N JAN supplemental redundancy 12 13 USB caps lock override 7 10 country keyboard types 7 6 default table 7 4 device type 7 5 keystroke delay 7 9 unknown characters 7 11 wand emulation code 39 full ASC...

Страница 384: ...12 53 transmit check digit 12 52 K keyboard wedge connection 5 2 keyboard wedge default parameters 5 3 keyboard wedge parameters 5 4 L LS 2 7 M maintenance 3 1 miscellaneous scanner parameters 13 3 m...

Страница 385: ...3 4 stand assembling 2 8 mounting 2 9 standard default parameters A 1 standard defaults 4 3 support center 2 xiv symbol support centers 2 xiv symbology default parameters 12 3 T technical specificati...

Отзывы: