1
10
APPLICATION LIMITS
Due to the dynamic pressure measurement principle, the device is only limited suitable for media with strongly fluctuating density.
The current fill level can then only be derived from the average density value.
Please note:
For level measurements in osmosis/VE water, the MEMPRO unit should not be operated without the MEMPRO BL aeration device due to the
outgassing properties of this medium.
INSTALLATION
The MEMPRO S6.6 / MEMPRO C S6.6 can be attached to containers or tanks in various ways:
• Measuring tube immersed in the tank from above
• Measuring hose immersed in the tank from above, measuring head mounted near the tank
Please note:
The lower end of the measuring tube or hose determines the 0% level measuring point.
The measuring tube must not stand on the tank bottom or be immersed in solid bottom mud!
Measuring range
MEMPRO with measuring tube
MEMPRO with measuring hose
max. filling level 100%
min. Fill level 100%
ELECTRICAL CONNECTION
Relay 4
Common root relay 1...3
Relay 1
Relay 2
Relay 3
L(+) N(-)
24 V DC power supply
± Rotary / press switch
LEDs
Digital display
LEV
05-09-2023
M-592.03-EN-AB
592-03
/2
HYDROSTATIC MULTIPLE
LIMIT VALUE SWITCH
MEMPRO S6.6
22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL
Tel
Fax
+33 (0)1 30 25 83 20
+33 (0)1 34 10 16 05
Web
www.bamo.eu
INTERNATIONAL