LIMIT SWITCH STIRRUP FIXING
Fix on the gate the stirrups with the screws supplied in the kit, the
stirrups must be set to activate the sensor on the motor before the
gate reaches the stoppers. Fine tune this regulation using the holes
made on the magnetic limit switches.
Always install the yellow magnet as closing limit switch and the
green magnet as opening limit switch.
The maximum distance between the magnet and the sensor inside
the motor must be less or equal to 15 mm. the position of the sensor
is indicated in figure 6.
When this operation has been done, lock the motor and proceed with
the electrical connections.
MAINTENANCE
This motoreducer does not need maintenance; anyway verify twice a
year all the security device.
Cover with key for
emergency release
Cement
platform
Rail
Pinion
93
35
Fixing
plate
Fixing
screws
Plastic pipes
for electrical
wirings
Sliding axis
55
Pinion
Limit switch sensor
Fig. 6