26
Eliminator Vacuum Tank (Tandem) User Manual
3 . Turn the
MASTER
switch
ON
and accelerate up to the desired speed . The Rite Rate system will start application as
soon as it detects forward movement by the tractor . Quickly you should notice a value displayed next to Rate on the
display . Generally the system will initially overshoot the target rate on startup and then slowly back down to the desired
preset rate . While the system is settling to the desired rate, the Raven SCS660 may buzz until the correct application
rate is reached (about 15-20 seconds) . Rate fluctuations of ±200 gallons per acre are not uncommon with this system .
A consistent ground speed during application will help reduce rate fluctuations .
4 . During application, the operator may switch the
FLOW CONTROL
back and forth between
RATE 1
and
RATE 2
or
switch to
MAN
to manually increase or decrease flow rate . To increase the flow rate, press and hold the switch in the
INC
position until the desired flow rate is reached . To decrease the flow rate, press and hold the switch in the
DEC
position until the desired flow rate is reached . The
FLOW CONTROL
can be switched back to
RATE 1
or
RATE 2
at
any time and the system will adjust to that flow rate .
5 . Near tile inlets and other areas where tillage is desired but application is not, turn the
MASTER
switch to
OFF
. This will
shut off the pump and close the discharge valve . The hydraulics may remain engaged and the injector in the ground .
6 . When approaching a turn around location or after the tank has emptied, turn the Master switch to Off and wait 3-4
seconds before raising the injector . This allows the discharge valve time to close and the slurry lines to be cleaned out .
Raising the injector before discharge valve becomes fully closed may result in the discharge valve remaining partially
open . Do not turn with the injector still in the ground, damage will occur!
7 . After completing a turn or refilling the slurry tank and returning to where you left off, repeat Field Application steps 1
through 3 .
8 . The Rite Rate system will store the programmed data for an extended period of time when disconnected from the
power source so the Raven should not need to be reprogrammed .
OPERATION
Rite Rate Flow System Field Operation (Continued)
Содержание ELIMINATOR VACUUM TANK Series
Страница 2: ...Serial Number Date of Purchase Purchased From Dealer s Address Dealer s Telephone...
Страница 4: ......
Страница 8: ...4 Eliminator Vacuum Tank Tandem User Manual...
Страница 9: ...Eliminator Vacuum Tank Tandem User Manual 5 Safety...
Страница 15: ...Eliminator Vacuum Tank Tandem User Manual 11 Technical Data...
Страница 19: ...Eliminator Vacuum Tank Tandem User Manual 15 Operation...
Страница 31: ...Eliminator Vacuum Tank Tandem User Manual 27 Maintenance...
Страница 45: ...Eliminator Vacuum Tank Tandem User Manual 41 Troubleshooting...
Страница 52: ...48 Eliminator Vacuum Tank Tandem User Manual...
Страница 53: ...Eliminator Vacuum Tank Tandem User Manual 49 Notes...
Страница 54: ...50 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Страница 55: ...51 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Страница 56: ...52 Eliminator Vacuum Tank Tandem User Manual Date Notes NOTES...
Страница 57: ......