BURNER CONNECTION TO THE BOILER
•
Position between the burner coupling flange (19) and the boiler
plate (1) the supplied insulating gaskets (13) and insulating cord
(2).
•
Adjust the position of the coupling flange (19) by loosening the
screws (6) so that the burner head enters the furnace to the
extent recommended by the generator manufacturer.
•
Fasten the burner to the boiler (1) by means of the stud bolts,
washers and the nuts provided (7).
CAUTION / WARNINGS
Completely seal the space between the burner sleeve and
the hole in the refractory material inside the boiler door with
suitable material.
ASSEMBLING THE GAS TRAIN
The gas train can be assembled in different ways: (8), (8a) .
Choose the most rational position for the set-up of the boiler room
and the position in which the gas pipeline arrives.