39
EN
APPLICATION OF THE BURNER TO BOILER
for model BGN 40 P ÷ 250 P (steel fixing flange)
1 - Boiler plate
2 - Insulating gasket
3 - Burner fixing flange
4 - Elastic collar
for model BGN 300 P - BGN 350 P (Aluminium coupling flange)
1 - Boiler plate
2 - Insulating gasket
3 - Burner fixing flange
4 - Stud bolt
5 - Locking nut with washer
REMARKS
When tightening the flange, it is important to do it evenly so that the inner faces are parallel between them.
Since the locking system is highly efficient, do not tighten the nuts too much.
During this operation (tightening of the flange locking nuts) keep the body of the burner lifted so that the
combustion head is kept in a horizontal position.
5 - Stud bolt
6 - Locking nut with washer
7 - Nut and washer for fastening the first flange
0002933330
0002933340