MC-624 Regulator Terminal Layout

1. 

IGNITION INPUT

 

2. 

POWER INPUT

3. 

STATOR IN

 

4. 

FIELD OUTPUT

5. 

ALT. TEMP. (+)

 

6. 

ALT. TEMP. (-)

7. 

BAT. #2 TEMP. (+)

8. 

BAT. #2 TEMP. (-)

 

9. 

BAT. #1 TEMP. (+) 

10. 

BAT. #1 TEMP. (-)

 

11. 

DASH LAMP

 

12. 

GROUND INPUT

 

Magnetic

Reed

Switch

1

2

3

4

5

6

8

9

10

11

12

7

Ignition

Connector 1

Conne

ctor 2

9

12

10

11

7

6

5

8

External Regulator

Plug

Positive Battery Sense

(Required for Internal Regulator Only)

Isolated Ground Terminal

MUST be connected to system ground

Positive Output

Terminal

HOUSE BATTERY

BANK

D+

1

2

3

4

10A

+

Содержание Max Charge MC-624

Страница 1: ...g your regulator 2 Remove loose fitting clothing or jewelry which could become entangled in your motor or other machinery prior to installing regulator 3 Wear ANSI approved safety eye wear and protect...

Страница 2: ...tors distance from alternator distance from inverters transmitters and other sources of RF noise convenient access and readability of the display The regulator wiring harness is 54 inches long providi...

Страница 3: ...th your battery manufacturer for specifics Your battery manufacturer may supply you with a C rate for charging and discharging The maximum amount of charging current your battery can safely handle is...

Страница 4: ...4 FIELD OUTPUT 5 ALT TEMP 6 ALT TEMP 7 BAT 2 TEMP 8 BAT 2 TEMP 9 BAT 1 TEMP 10 BAT 1 TEMP 11 DASH LAMP 12 GROUND INPUT Magnetic Reed Switch 1 2 3 4 5 6 8 9 10 11 12 7 Ignition Connector 1 Connector 2...

Страница 5: ...plug which is pre installed on the voltage regulator When the tachometer is connected via the MC 624 the regulator will ensure that the tachometer will not discontinue supplying field current when the...

Страница 6: ...e sensor lug to the battery negative post closest to the center of the battery bank Extend sensor cable to the regulator 2 Connect the temperature sensor to the Bat 1 Temp terminals on the regulator I...

Страница 7: ...operly mounted and the regulator wiring is installed the MC 624 is ready for pre flight testing Before turning on the engine it is advisable to check voltages at the following terminal connections to...

Страница 8: ...are met 5 Ramps down to Absorption voltage 6 Absorption Charge Regulator continues to control the alternator s output voltage for an additional 18 minutes at approximately 2 10 s of a volt below bulk...

Страница 9: ...ar net Customer Service 1 360 435 6100 x1 Technical Support 1 360 435 6100 x3 Tech Service is available Monday Friday 8 30am 7 30pm EST Regulator Programming Flow Chart More details can be found on pa...

Страница 10: ...s Standard Flooded Halogen Systems Lithium Yes Yes Yes Yes Yes Balmar Alternator Models 6 Series Alternators 70A 150A Yes Yes Yes Yes Yes Yes AT Series Alternator 165A 200A Yes Yes Yes Yes 9 Series La...

Страница 11: ...ENGINE MODE IS IN OPERATION E52 BELT LOAD MANAGER IS IN OPERATION In addition to the information provided in the basic display shown above the MC 624 long display provides the following data The long...

Страница 12: ...e reed switch then releasing the reed switch be removing the magnet from the RED dot on the epoxy potting Basic Programming Programming For Battery Type The MC 624 features selectable programs for SEV...

Страница 13: ...ramming mode The Advanced Programming Modes are as follows dLc Start Delay Controls time from regulator activation to start of charging Factory preset at one second Adjustable to a maximum of 999 seco...

Страница 14: ...me the batteries will be held at equalization voltage Maximum time adjustment is three hours If manufacturer guidelines require longer equalization times allow for maximum time and reset for additiona...

Страница 15: ...ery Temperature 125 F Requires installation of MC TS B sensor cable System Troubleshooting Regulator Troubleshooting The majority of charging difficulties can be attributed to damage corrosion or wear...

Страница 16: ...FOR FIELD OUTPUT TO OCCUR ENSURE THAT VOLTAGE IS ABOVE 22V WHEN TESTING SYSTEM If voltage is not present on the RED or BROWN wires the regulator will not work If voltage is as expected at the RED and...

Страница 17: ...y longer than necessary to detect charging If the system is not charging remove the alternator and have it inspected by a qualified alternator shop or call Balmar for warranty evaluation To test the a...

Страница 18: ...18 www balmar net Customer Service 1 360 435 6100 x1 Technical Support 1 360 435 6100 x3 Tech Service is available Monday Friday 8 30am 7 30pm EST NOTES...

Страница 19: ...plication maintenance or modification or b any misuse contrary to the instructions provided with the product or c loss or d malfunctions caused by other equipment or e acts of God Examples of conditio...

Страница 20: ...he world To Find a CDI distribution partner visit www cdielectronics com Both Balmar and CDI Products are manufactured in our ISO 9000 Certified Factory in Huntsville Alabama Please read carefully All...

Отзывы: