164
2. Setting of
Timer2
(purple on the master camera):
Figure 3: wxPropView - Setting of
Timer2
3. Assigning timer to DigOut (orange box in Figure 2).
1.18.3.3
Outputting a pulse at every other external trigger
To do this, please follow these steps:
1. Switch
"Trigger Mode"
to
"On"
and
2. Select the
"Trigger Source"
, e.g.
"Line5"
.
3. Use
"Counter1"
and count the number of input trigger by setting the
"Counter Duration"
to
"2"
.
4. Afterwards, start
"Timer1"
at the end of
"Counter1"
:
MATRIX VISION GmbH