![Balluff BVS SC-C1280Z00-30-000 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/balluff/bvs-sc-c1280z00-30-000/bvs-sc-c1280z00-30-000_user-manual_469643038.webp)
38
BVS SC-_1280Z00-30-0-0
SMART
CAMERA
Fieldbus
Data modules for IO-Link inputs and outputs
Data module
Data width
Input
Output
IOL_I/O_1/_1byte
1 byte
1 byte
IOL_I/O_2/_2byte
2 bytes
2 bytes
IOL_I/O_2/_2byte
2 bytes
2 bytes
IOL_I/O_4/_4byte
4 bytes
4 bytes
IOL_I/O_4/_2byte
4 bytes
2 bytes
IOL_I/O_2/_8byte
2 bytes
8 bytes
IOL_I/O_4/_8byte
4 bytes
8 bytes
IOL_I/O_8/_2byte
8 bytes
2 bytes
IOL_I/O_8/_4byte
8 bytes
4 bytes
IOL_I/O_8/_8byte
8 bytes
8 bytes
IOL_I/O_10/_10byte
10 bytes
10 bytes
IOL_I/O_4/_32byte
4 bytes
32 bytes
IOL_I/O_32/_4byte
32 bytes
4 bytes
IOL_I/O_16/_16byte
16 bytes
16 bytes
IOL_I/O_24/_24byte
24 bytes
24 bytes
IOL_I/O_32/_32byte
32 bytes
32 bytes
Additional modules (slot 3 to 9)
Slot
Subslot
Input
Output
Contents
3
1
1 byte
-
IO-Link station diagnostics
3
1
1 byte
-
IO-Link extended diagnostics
4
1
1 byte
-
Input pin 4
5
1
-
1 byte
Output pin 4
6
1
-
1 byte
Restart pin 4*
7
1
1 byte
-
Input Pin 2
8
1
-
1 byte
Output pin 2
9
1
-
1 byte
Restart pin 2*
* If the modules Restart pin 4/2 are inserted, no automatic restart of the pin is performed after an actuator short circuit. A
restart is performed only after the respective restart module is set to the value 01
hex
.
Byte allocation of diagnostic modules
Slot 3 can host one of two diagnostic modules. Both modules have input data of length 1 byte and no output data.
NOTE
Project planning software of various providers mostly offers graphical assistance during
configuration; the configuration string is automatically created.
Содержание BVS SC-C1280Z00-30-000
Страница 1: ...BVS SC _1280Z00 30 0 0 SMARTCAMERA Fieldbus...
Страница 2: ......
Страница 5: ...www balluff com 5 BVS Cockpit User s manual...
Страница 43: ...www balluff com 43 BVS Cockpit Determining the station name 1 Define the PROFINET station name of the device...
Страница 53: ...www balluff com 53 BVS Cockpit 3 Select SMARTCAMERA Module BVS_SC 1280 and apply to the configuration...