Balluff BTL6-V11V-M Series Скачать руководство пользователя страница 6

6

english

0.5 Ø 25

71

12.8

25

60

Ø D1

G

45

46

Fig. 3-1:  BTL6... transducer, construction and function

3.1 

Construction

Electrical connection: 

The electrical connection is made 

via a connector (see Type code breakdown on page 16).

BTL housing: 

Aluminum housing containing the 

processing electronics.

Mounting thread: 

We recommend assembling these 

transducers on the fastening screw thread:

 

– BTL6-…-A/B: M18×1.5

 

– BTL6-…-Y/Z: 3/4"-16UNF
The transducer with Ø 10.2 mm has an additional thread 

at the end of the rod to support larger nominal lengths.

Magnet: 

Defines the position to be measured on the 

waveguide. Magnets are available in various models and 

must be ordered separately (see Accessories on page 14).

Nominal length:

 Defines the available measuring range. 

Rods with various nominal lengths from 25 mm to 

4012 mm are available depending on the version:

 

– Ø 10.2 mm: Nominal length from 25 mm to 4012 mm

 

– Ø 8 mm: Nominal length from 25 mm to 1016 mm

Damping zone:

 Area at the end of the rod that cannot be 

used for measurements, but which may be passed over.

Construction and function

1) Unusable area
2) Not included in scope of delivery

Version

D1

G

...-A/B/Y/Z-...

10.2 mm

Thread M4x4/6 deep

...-A8/B8/Y8/Z8-...

8 mm

No thread

1)

3.2 

Function

The BTL6 transducer contains the waveguide which is 

protected by an outer stainless steel tube (rod). A magnet 

is moved along the waveguide. This magnet is connected 

to the system part whose position is to be determined. The 

magnet defines the position to be measured on the 

waveguide.

An internally generated INIT pulse interacts with the 

magnetic field of the magnet to generate a torsional wave 

in the waveguide which propagates at ultrasonic speed. 

The component of the torsional wave which arrives at the 

end of the waveguide is absorbed in the damping zone to 

prevent reflection. The component of the torsional wave 

which arrives at the beginning of the waveguide is 

converted by a coil into an electrical signal. The travel time 

of the wave is used to calculate the position.

This information is transferred via the VARAN interface. 

VARAN is an industrial bus system based on the physical 

layer of the Ethernet (see www.varan-bus.net).

BTL6...S115

Nominal length =
Measuring range

Mounting surface

B: 30-1 mm

Z: 2"-0.04"

Damping zone 1)

Magnet 2)

Thread size

B: M18x1.5

Z: 3/4"-16UNF

1)

Mounting surface

A: 30-1 mm

Y: 2"-0.04"

Thread size

A: M18x1.5

Y: 3/4"-16UNF

2)

BTL6-V11V-M _ _ _ _ -A/B/Y/Z(8)-S115

Micropulse Transducer - Rod Style

Содержание BTL6-V11V-M Series

Страница 1: ...User s Guide english BTL6 V11V M_ _ _ _ A B Y Z 8 S115...

Страница 2: ...www balluff com...

Страница 3: ...delines 7 4 2 Preparing for installation 7 4 3 Installing the transducer 8 4 3 1 Installation recommendation for hydraulic cylinders 8 4 4 Electrical connection 9 4 5 Shielding and cable routing 9 5 S...

Страница 4: ...at our products meet the requirements of EU Directive 2004 108 EC EMC Directive The transducer meets the requirements of the following generic standards EN 61000 6 1 noise immunity EN 61000 6 2 noise...

Страница 5: ...lations pertaining to the work to be done The operator is responsible for ensuring that local safety regulations are observed In particular the operator must take steps to ensure that a defect in the...

Страница 6: ...Version D1 G A B Y Z 10 2 mm Thread M4x4 6 deep A8 B8 Y8 Z8 8 mm No thread 1 3 2 Function The BTL6 transducer contains the waveguide which is protected by an outer stainless steel tube rod A magnet is...

Страница 7: ...4 1 Bore diameter if installed in a hydraulic cylinder 4 2 Preparing for installation Installation note We recommend using non magnetizable material to mount the transducer and magnet Horizontal assem...

Страница 8: ...ar Dimensioning of the detailed solutions is the responsibility of the cylinder manufacturer The slide element material must be suitable for the appropriate load case medium used and application tempe...

Страница 9: ...ame ground potential Shielding To ensure electromagnetic compatibility EMC observe the following Connect transducer and controller using a shielded cable Shielding Braided copper shield with minimum 8...

Страница 10: ...e safety instructions of the equipment or system manufacturer 1 Check connections for tightness and correct polarity Replace damaged connections 2 Turn on the system 3 Check measured values and readju...

Страница 11: ...t r w 1 Tab 6 1 Memory assignment 6 Device profile Description of status register Error This bit is set if the number of detected stops is less than the number of magnets entered in the Config registe...

Страница 12: ...ble in the position result register see Memory address space mapping on page 11 The PLL_Sync_out time interval must be defined by the user during startup The position of the magnet can be calculated u...

Страница 13: ...tection per IEC 60529 when attached IP 67 7 3 Supply voltage Voltage stabilized3 20 to 28 V DC Ripple 0 5 Vss Current draw at 24 V DC 75 mA Inrush current 4 A 0 5 ms Reverse polarity protection Up to...

Страница 14: ...L P 1013 4R BTL P 1013 4S BTL P 1012 4R Spacer 8 mm material polyoxymethylene POM BTL5 P 4500 1 magnet solenoid Weight Approx 90 g Housing Plastic Operating temperature 40 C to 60 C BTL P 1028 15R spe...

Страница 15: ...igurable M12 8 pin Fig 8 3 Connector BCC M488 0000 1A 000 43x834 000 BCC M478 0000 1A 000 43x834 000 Straight connector freely configurable M12 8 pin Fig 8 4 Connector BCC M478 0000 1A 000 43x834 000...

Страница 16: ...thread M18x1 5 O ring rod diameter 10 2 mm B Metric mounting thread M18x1 5 O ring rod diameter 10 2 mm Y 3 4 16UNF thread O ring rod diameter 10 2 mm Z 3 4 16UNF thread O ring rod diameter 10 2 mm A8...

Страница 17: ...5433071 10 0 393700787 Tab 10 1 Conversion table mm to inches 1 inch 25 4 mm inches mm 1 25 4 2 50 8 3 76 2 4 101 6 5 127 6 152 4 7 177 8 8 203 2 9 228 6 10 254 Tab 10 2 Conversion table inches to mm...

Страница 18: ...Germany Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 8...

Отзывы: