www.balluff.com
BTL6-A/E500/B50 _ -M _ _ _ _ -E2/E28-KA _ _ /LA _ _ -ZA _ _
Magnetostrictive Linear Position Sensor – Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The BTL magnetostrictive linear position sensor, together
with a machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty.
Opening the BTL or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.
General safety notes
Installation
and
startup
may only be performed by
trained specialists.
The
operator
is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the BTL will not result
in hazards to persons or equipment.
If defects and unresolvable faults occur in the BTL, take it
out of service and secure against unauthorized use.
Dimensions and function
The BTL contains the waveguide which is protected by an
outer stainless steel tube (rod). A magnet is moved along
the waveguide. This magnet is connected to the system
part whose position is to be determined. The magnet
defines the position to be measured on the waveguide.
Downloading further instructions
A complete user’s guide can be downloaded from the
Internet at
www.balluff.com
or requested via e-mail from
.
See the user’s guide for information on
standard/additional regulations or compatibility
tests for the BTL6.
Electrical connection
Pin
BTL6-…-ZA0N
BTL6-…-ZA16
BTL6-…-ZA0R
BTL6-…-ZA17
1
10…30 V DC
2
Not used
1)
Output signal
3
GND
2)
4
Output signal
Not used
1)
Pin assignment (view of
connector pins of BTL),
4-pin M12 circular plug
1) Unassigned leads can be connected to GND on the controller side
but not to the shield.
2) Reference potential for supply voltage and EMC-GND.
Output signal
-A500
-B500
-B502
-B503
-E500
0…10 V
0…5 V
0.25…4.75 V 0.5…4.5 V 4…20 mA
3) Unusable area
4) Not included in scope of delivery
Damping zone
Magnet
3)
Nominal length =
Measuring range
4)
3)
Version
D1
G
...-E2-...
10.2 mm
Thread M4x4/
6 deep
...-E28-...
8 mm
No thread
Mounting
surface
O-ring
Support ring
1
english
3
Ø D1
G
Ø 48 f7
Ø 38.9
Ø 24
63.5
30
25.2
21
Ø 4.4
25
7.5
4
45°
~13
R2
Ø 46
BTL6-…-KA…-ZA_ _
BTL6-…-LA…-ZA_ _
M12 contact insert
-1