www.balluff.com
9
english
4
Installation and connection (continued)
4.3
Floating magnets
The following must be observed when installing the
magnet:
– To ensure the accuracy of the position measuring
system, the magnet is attached to the moving member
of the machine using non-magnetizable screws
(stainless steel, brass, aluminum).
– The moving member must guide the magnet on a track
parallel to the transducer.
– Ensure that the distance A between parts made of
magnetizable material and the magnet is at least
10 mm (see Figures 4-3 to 4-7).
– Maintain the following values for distance B between
the magnet and transducer and for center offset C (see
Figures 4-3 to 4-7):
Type of magnet
Distance B
1)
Offset C
BTL5-P-3800-2
0.1…4 mm
± 2 mm
BTL5-P-5500-2
5…15 mm
± 15 mm
BTL5-P-4500-1
0.1…2 mm
± 2 mm
BTL6-A-3800-2
4…8 mm
2)
± 5 mm
BTL6-A-3801-2
4…8 mm
2)
± 5 mm
1)
The selected distance must stay constant over the entire measuring length.
2)
For optimum measurement results, a distance B of 6 to 8 mm is
recommended.
Tab. 4-1: Distance and offset for magnets (see Figures 4-3 to 4-7)
Fig. 4-3:
B
C
1
34+4
A
A
39+4
Dimensions and distances with BTL5-P-3800-2 magnet
Fig. 4-4:
C
B
1
A
A
45+10
50+10
Dimensions and distances with BTL5-P-5500-2 magnet
Fig. 4-5:
C
B
1
A
A
58+4
53+4
Dimensions and distances with BTL6-A-3800-2 magnet
Fig. 4-6:
C
B
1
A
A
47+4
42+4
Dimensions and distances with BTL6-A-3801-2 magnet
Fig. 4-7:
1
65+2
B
A
A
C
41.5+2
4
Dimensions and distances with BTL5-P-4500-1
electromagnet (24 V/100 mA)
The measuring range is offset by 4 mm towards
the transducer plug (see Figure 4-7).
Plug with
LED
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Содержание BTL6-A 5 00-M0500-PF-S115
Страница 1: ...BTL6 A C E G500 M _ _ _ _ PF S115 User s Guide english ...
Страница 2: ...www balluff com ...