www.balluff.com
17
english
10.1
Accuracy
The specifications are typical values for BTL6-A/C/E/G... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-2814-1S or BTL5-T-2814-1S
magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
BTL6-A/G...
350 µV
≥ 5 µm
BTL6-C/E...
700 nA
≥ 5 µm
Repeat accuracy
≤ ±0.002 % FS
≥ ±5 µm
Sampling rate
(dependent on the nominal length)
Max. 2 kHz
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
±200 µm
±0.04 % FS
Temperature coefficient
1)
≤ 30 ppm/K
Max. detectable speed
10 m/s
10.2
Ambient conditions
2)
Operating temperature
−25°C…+70°C
Storage temperature
−40°C…+100°C
Relative humidity
< 90%, non-condensing
Shock rating
Continuous shock
per EN 60068-2-27
3)
50 g/6 ms
50 g/2 ms
Vibration
per EN 60068-2-6
3)
12 g, 10…2000 Hz
Degree of protection per
IEC 60529
IP67
(when attached)
10.3
Supply voltage (external)
Voltage, stabilized
4)
10…30 V DC
Ripple
≤ 0.5 V
PP
Current draw (at 24 V DC)
≤ 150 mA
Inrush current
≤ 3 A/0.5 ms
Reverse polarity protection
5)
Up to 36 V
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V DC
10.4
Output
BTL6-A… Output voltage
Load current
0…10 V
Max. 5 mA
BTL6-C… Output current
Load resistance
0.1…20 mA
≤ 500 ohms
BTL6-E… Output current
Load resistance
4…20 mA
≤ 500 ohms
BTL6-G… Output voltage
Load current
−10…10 V
Max. 5 mA
Short circuit resistance
Signal cable to 36 V
Signal cable to GND
10.5
Input
Programming inputs La/Lb
10…30 V DC
High-active
Overvoltage protection
Up to 36 V
10.6
Dimensions, weights
Housing height
20.8 mm
Nominal length
50…4572 mm
Weight (depends on length)
Approx. 1 kg/m
Housing material
Aluminum
1)
Nominal length 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard, resonances
excluded
4)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source
as defined in UL 60950-1, or a class 2 power supply as defined
in UL 1310 or UL 1585.
5)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
10
Technical data
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Содержание BTL6-A 5 00-M0500-PF-S115