16
english
9
Resetting all values (reset)
NOTICE!
Interference in function
Resetting the values while the system is running may
result in malfunctions.
►
Stop the system before performing the reset.
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
LED display
LED
1. Activate reset
►
Simultaneously activate
a
and
b
for at least 4 s.
> 4 s
a
b
2. Reset
►
Simultaneously activate
a
and
b
for at least 4 s.
> 4 s
a
b
After activation:
⇒
All values are reset.
⇒
Current position value is displayed.
⇒
Reset is deactivated.
3. Abort reset
Resetting can be aborted without any changes
being saved after the
Activate reset
step.
►
Briefly activate
a
and
b
simultaneously (< 1 s).
< 1 s
a
b
⇒
Current position value is displayed.
LED legend:
LED green
LED flashing green
LED red
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing