62
english
Ø window 1 = 4.6
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Ø window 2 = 5.8
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Ø window 3 = 6
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Ø window 4 = 4.8
2
5
9
6
1
3
5
8
9
4
6
5
8
7
4
9
6
1
3
5
Fig. 6-6: Periodic window approach
Fig. 6-7 shows the moving average using the method of
the periodic window.
Fig. 6-7:
Moving average (window width 9)
Value
Periodic window
Periodic window approach (example)
6.5.3 Process Data
Object ID
Name
Description
Direction
0x0053 (83) Minimum
Minimum value
Input
0x0054 (84) Maximum
Maximum value
Input
0x0055 (85) Average
Average
Input
0x0056 (86) Moving Average
Repeatedly calculated average value
Input
0x0057 (87) Status
Status value
Input
0x0058 (88) Number Of Samples
Number of measurement values for the
calculation of minimum, maximum and
average
Input
Tab. 6-23: Basic statistics – process data
6
Secondary Device Functions (continued)
BOS R254K-UUI-RH11-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-RH11-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI RH11 S4...
Страница 2: ...www balluff com...
Страница 3: ...BOS R254K UUI RH11 S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 108: ......
Страница 109: ...BOS R254K UUI RH11 S4 Configuration Guide english...
Страница 110: ...www balluff com...