www.balluff.com
7
3
Getting Started
3.3
Mechanical
connection
The BNI IOL-800-000-Z03x modules are attached by using an M18 nut.
3.4
Electrical
connection
The BNI IOL-800-000-Z03x modules require no separate supply voltage connection. Power
is provided through the IO-Link interface by the host IO-Link Master.
3.5
Function ground
Note
The FE connection from the housing to the machine must be low-impedance
and as short as possible.
3.6
IO-Link
connection
IO-Link (M12, A-coded, male)
Pin
Function
1
Power supply controller, +24V
2
-
3
GND, reference potential
4
C/Q, IO-Link Data transmission channel
Smart Light
connection
Connection protection ground to FE terminal, if present.
Connect the incoming IO-Link line to the Smart Light.
Note
A standard 3 wire sensor cable is used for connecting to the host IO-Link
master.
Module versions
Version
Description
BNI IOL-800-000-Z036
1 segment configurable signal light with runlight
mode and flexible mode.
BNI IOL-800-000-Z037
1 segment configurable signal light with runlight
mode, flexible mode and buzzer.
FE terminal
with a screw
to connect
protection
ground