background image

 

www.balluff.com 

   

   

 

Getting Started 

3.3

 

Mechanical 
connection 

  The BNI IOL-800-000-Z03x modules are attached by using an M18 nut. 

 

3.4

 

Electrical 
connection

 

  The BNI IOL-800-000-Z03x modules require no separate supply voltage connection. Power 

is provided through the IO-Link interface by the host IO-Link Master. 

 

3.5

 

Function ground 

 

 

 

 

Note 

The FE connection from the housing to the machine must be low-impedance 
and as short as possible. 

 

 

3.6

  IO-Link 

connection

 

 
 
 
 
 
 
 

  IO-Link (M12, A-coded, male) 

 

 

Pin 

Function 

Power supply controller, +24V 

GND, reference potential 

C/Q, IO-Link Data transmission channel 

 

 

 

 

 

Smart Light 
connection 

 
 
 
 

 

 

Connection protection ground to FE terminal, if present. 

 

Connect the incoming IO-Link line to the Smart Light. 

 

Note 

A standard 3 wire sensor cable is used for connecting to the host IO-Link 
master. 

 

 

 

Module versions 

 

Version 

Description 

BNI IOL-800-000-Z036 

1 segment configurable signal light with runlight 
mode and flexible mode. 

BNI IOL-800-000-Z037 

1 segment configurable signal light with runlight 
mode, flexible mode and buzzer. 

 

 

   

 

FE terminal 
with a screw 
to connect 
protection 
ground 

Содержание BNI IOL-800-000-Z036

Страница 1: ...BNI IOL 800 000 Z036 BNI IOL 800 000 Z037 Smart Light User s Guide...

Страница 2: ...t description of the functionality 8 3 8 Segment mode 8 3 9 Runlight mode 8 3 10 Flexible mode 8 3 11 Synchronisation 8 4 IO Link Interface 9 4 1 IO Link Data 9 4 2 Process data Output data 9 BNI IOL...

Страница 3: ...e IO Link BNI IOL 800 000 Z03x www balluff com 2 5 3 Electrical data 16 5 4 Operating conditions 16 5 5 LED indicator 17 Status LED 17 6 Appendix 18 6 1 Product ordering code 18 6 2 Order information...

Страница 4: ...tion result Action instruction 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross referenc...

Страница 5: ...ded use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this opera...

Страница 6: ...5 3 Getting Started 3 1 Overview BNI IOL 800 000 Z036 Fig 3 1 BNI IOL 800 000 Z036 1 Cap 2 Segment 1 3 Socket 4 M12 connector 5 M18 thread for mounting 6 Status LED 7 LED4 8 LED3 9 LED2 10 LED1 1 2 3...

Страница 7: ...Z03x www balluff com 6 3 Getting Started 3 2 Overview BNI IOL 800 000 Z037 Fig 3 2 BNI IOL 800 000 Z037 1 Cap with buzzer 2 Segment 1 3 Socket 4 M12 connector 5 M18 thread for mounting 6 Status LED 7...

Страница 8: ...nection IO Link M12 A coded male Pin Function 1 Power supply controller 24V 2 3 GND reference potential 4 C Q IO Link Data transmission channel Smart Light connection Connection protection ground to F...

Страница 9: ...nlight mode In the runlight mode the complete module displays a running light effect In this case all of the LEDs are working as one runlight effect The runlight mode is controlled by ISDU registers T...

Страница 10: ...epending on the selected mode segment mode runlight mode or flexible mode BNI IOL 800 000 Z03x Segment Mode Byte 0 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync impulse Sync start Segment 1 blink...

Страница 11: ...Bit 5 6 Sync start Sync impulse available from software version 3 0 These bits are rising edge sensitive BNI IOL 800 000 Z03x Flexible Mode Byte 0 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync im...

Страница 12: ...32 Byte string adjustable by the user Parameter Data ISDU Object name Length Range Default Value Index Sub index 40hex 0 Mode 1 Byte 0 or 2 0 4Dhex 0 Runlight mode background color 1 Byte 0 7 0 4Ehex...

Страница 13: ...ption Background color The background of the runlight effect can be set in this register Bit 0 2 Background color 000 Off 001 Green 010 Red 011 Yellow 100 Blue 101 Orange 110 User defined 111 White Ru...

Страница 14: ...This register sets the brightness for each channel red green and blue Values from 0x00 to 0x7F are accepted for each channel This register can be accessed through the subindices 0 1 2 or 3 Reading wr...

Страница 15: ...y cycle or flash The blinking of the desired segment must be activated in process data to enable blinking Flexible mode LEDx settings A1hex A4hex This register contains the settings for the flexible L...

Страница 16: ...el User defined color green channel User defined color green channel Buzzer type FEhex This register is available only for BNI IOL 800 000 Z037 The type of the buzzer sound can be set in this register...

Страница 17: ...800 000 Z036 117 60 60 mm BNI IOL 800 000 Z037 138 5 60 60 mm 5 3 Electrical data Operating voltage 18 30 2 V DC per EN 61131 2 Ripple 1 Current draw all segments off 30 mA 24V Current draw all segmen...

Страница 18: ...tus for supply and communication The status LED indicates the current status of the power supply and the communication It can be switched on switched of and flashing Communication error Communication...

Страница 19: ...consists of the following components signal light M18x1 nut rubber foot screw M4 spring washer user s guide BNI IOL 800 000 Z03x Balluff Networking Interface IO Link Interface 800 Smart Light 1 Segme...

Страница 20: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 915739 726 EN 06 123333 Edition L16 Replaces Edition K15 Subject...

Отзывы: