background image

Balluff Network Interface / IO-Link BNI IOL-800-000-Z03x 
 

www.balluff.com 

   

   

 

2

 

Safety 

2.1

 

Intended use 
 

  This  guide  describes  the  Balluff  BNI  IOL-800-000-Z03x  for  the  application  as  status  light 

module.  Hereby  it  is  about  an  IO-Link  device  which  communicates  by  means  of  IO-Link 
protocol with the superordinate IO-Link master assembly. 

 

2.2

 

Installation and 
startup 

 

 

Attention! 

Installation and startup are to be performed only by trained specialists. Qualified 
personnel are persons who are familiar with the installation and operation of the 
product, and who fulfills the qualifications required for this activity. Any damage 
resulting from unauthorized manipulation or improper use voids the 
manufacturer's guarantee and warranty. The Operator is responsible for 
ensuring that applicable of safety and accident prevention regulations are 
complied with. 

 

 

2.3

 

General safety 
instructions

 

 

Commissioning and inspection 

Before commissioning, carefully read the operating manual. 
The system must not be used in applications in which the safety of persons is dependent on 
the function of the device. 

Authorized Personnel 

Installation and commissioning may only be performed by trained specialist personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this operating 
manual 

Obligations of the Operating Company 

The device is a piece of equipment from EMC Class A. Such equipment may generate RF 
noise. The operator must take appropriate precautionary measures. The device may only be 
used with an approved power supply. Only approved cables may be used. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 
Intended use is ensured only when the housing is fully installed. 

 

2.4

 

Resistance to 
aggressive 
substances 

 

 

Attention! 

The BNI modules generally have a good chemical and oil resistance. When 
used in aggressive media (eg chemicals, oils, lubricants and coolants each in 
high concentration (ie, low water content)) must be checked prior application-
related material compatibility. In the event of failure or damage to the BNI 
modules due to such aggressive media are no claims for defects. 

 

 

 

 

Hazardous 
voltage 

 

 

Attention! 

Disconnect all power before servicing equipment. 

 

 

 

 

 

Note 

In the interest of product improvement, the Balluff GmbH reserves the right to 
change the specifications of the product and the contents of this manual at any 
time without notice. 

 

 

Содержание BNI IOL-800-000-Z036

Страница 1: ...BNI IOL 800 000 Z036 BNI IOL 800 000 Z037 Smart Light User s Guide...

Страница 2: ...t description of the functionality 8 3 8 Segment mode 8 3 9 Runlight mode 8 3 10 Flexible mode 8 3 11 Synchronisation 8 4 IO Link Interface 9 4 1 IO Link Data 9 4 2 Process data Output data 9 BNI IOL...

Страница 3: ...e IO Link BNI IOL 800 000 Z03x www balluff com 2 5 3 Electrical data 16 5 4 Operating conditions 16 5 5 LED indicator 17 Status LED 17 6 Appendix 18 6 1 Product ordering code 18 6 2 Order information...

Страница 4: ...tion result Action instruction 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross referenc...

Страница 5: ...ded use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this opera...

Страница 6: ...5 3 Getting Started 3 1 Overview BNI IOL 800 000 Z036 Fig 3 1 BNI IOL 800 000 Z036 1 Cap 2 Segment 1 3 Socket 4 M12 connector 5 M18 thread for mounting 6 Status LED 7 LED4 8 LED3 9 LED2 10 LED1 1 2 3...

Страница 7: ...Z03x www balluff com 6 3 Getting Started 3 2 Overview BNI IOL 800 000 Z037 Fig 3 2 BNI IOL 800 000 Z037 1 Cap with buzzer 2 Segment 1 3 Socket 4 M12 connector 5 M18 thread for mounting 6 Status LED 7...

Страница 8: ...nection IO Link M12 A coded male Pin Function 1 Power supply controller 24V 2 3 GND reference potential 4 C Q IO Link Data transmission channel Smart Light connection Connection protection ground to F...

Страница 9: ...nlight mode In the runlight mode the complete module displays a running light effect In this case all of the LEDs are working as one runlight effect The runlight mode is controlled by ISDU registers T...

Страница 10: ...epending on the selected mode segment mode runlight mode or flexible mode BNI IOL 800 000 Z03x Segment Mode Byte 0 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync impulse Sync start Segment 1 blink...

Страница 11: ...Bit 5 6 Sync start Sync impulse available from software version 3 0 These bits are rising edge sensitive BNI IOL 800 000 Z03x Flexible Mode Byte 0 Bit 7 6 5 4 3 2 1 0 Description Buzzer state Sync im...

Страница 12: ...32 Byte string adjustable by the user Parameter Data ISDU Object name Length Range Default Value Index Sub index 40hex 0 Mode 1 Byte 0 or 2 0 4Dhex 0 Runlight mode background color 1 Byte 0 7 0 4Ehex...

Страница 13: ...ption Background color The background of the runlight effect can be set in this register Bit 0 2 Background color 000 Off 001 Green 010 Red 011 Yellow 100 Blue 101 Orange 110 User defined 111 White Ru...

Страница 14: ...This register sets the brightness for each channel red green and blue Values from 0x00 to 0x7F are accepted for each channel This register can be accessed through the subindices 0 1 2 or 3 Reading wr...

Страница 15: ...y cycle or flash The blinking of the desired segment must be activated in process data to enable blinking Flexible mode LEDx settings A1hex A4hex This register contains the settings for the flexible L...

Страница 16: ...el User defined color green channel User defined color green channel Buzzer type FEhex This register is available only for BNI IOL 800 000 Z037 The type of the buzzer sound can be set in this register...

Страница 17: ...800 000 Z036 117 60 60 mm BNI IOL 800 000 Z037 138 5 60 60 mm 5 3 Electrical data Operating voltage 18 30 2 V DC per EN 61131 2 Ripple 1 Current draw all segments off 30 mA 24V Current draw all segmen...

Страница 18: ...tus for supply and communication The status LED indicates the current status of the power supply and the communication It can be switched on switched of and flashing Communication error Communication...

Страница 19: ...consists of the following components signal light M18x1 nut rubber foot screw M4 spring washer user s guide BNI IOL 800 000 Z03x Balluff Networking Interface IO Link Interface 800 Smart Light 1 Segme...

Страница 20: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 915739 726 EN 06 123333 Edition L16 Replaces Edition K15 Subject...