14
english
5.2.5 Grounding
To counteract EMC interference, the functional earth
connection must be used.
►
Connect the earth terminal to the functional earth (FE)
of the machine.
The FE connection between the housing and
the machine must have a low impedance and
be as short as possible.
►
Use the grounding strap included in the
scope of delivery.
Fig. 5-5: Ground connection
5.3
Current limitation when using the extension
port
Variant BNI IOL-314-S52-P012
Observe the current limitation: The output is split 1:1
between the first and second device.
Fig. 5-6: Current split when connecting a second device via the
extension port
Variant BNI IOL-314-S52-P071
There is no current limitation to consider because the
current for the second device is supplied independently via
the auxiliary voltage connection.
5
Installation and connection (continued)
BNI IOL-314-S52-P012 / BNI IOL-314-S52-P071
Network interface – Digital hub